Approvals
and Codes

Approval Listings
and Codes

Appliance Certification

The Heat-N-Glo fireplace models discussed in this
Installers Guide have been tested to certification
standards and listed by the applicable laboratories.

     CERTIFICATION

MODEL

LABORATORY

  TYPE

      STANDARD

BAY-INS

Underwriters

    Vented Gas

       ANSI 

Z21.88•CSA2.33

Laboratories

Fireplace Heaters

Installation Codes

The fireplace installation must conform to local codes. Before installing the
fireplace, consult the local building code agency to ensure that you are in
compliance with all applicable codes, including permits and inspections.

In the absence of local codes, the fireplace installation must conform to the
National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA-
B149 Installation Codes (in Canada).  The appliance must be electrically
grounded in accordance with local codes or, in the absence of local codes with
the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the
CSA C22.1 Canadian Electric Code (in Canada).

These models may be installed in a bedroom or bed-sitting room in the U.S.A.
and Canada.

High Altitude Installations

U.L. Listed gas fireplaces are tested and approved for elevations from 0 to 2,000
feet in the U. S. A. and are tested and approved for elevations from 0 to 4,500
feet in Canada.

When installing this fireplace at an elevation above 2,000 feet (in the United
States), it may be necessary to decrease the input rating by changing the
existing burner orifice to a smaller size. Input should be reduced four percent
(4%) for each 1,000 feet above sea level, unless the heating value of the gas
has been reduced, in which case this general rule will not apply. To identify the
proper orifice size, check with the local gas utility.

When installing this fireplace at an elevation between 2,000 and 4,500 feet (in
Canada), the input rating must be reduced by ten percent (10%).

When installing this fireplace at an elevation above 4,500 feet (in Canada),
check with local authorities.

Consult your local gas utility for assistance in determining the proper orifice for
your location.

Содержание BAY-INS

Страница 1: ...ITH APPLIANCE FOR FUTURE REFERENCE 1 This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes 2 This appliance is only for use...

Страница 2: ...PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should be CAREF...

Страница 3: ...Vent System 5 Vent System Approvals 5 Step 2 Positioning Leveling and Securing the Fireplace 10 Step 3 The Gas Control Systems 10 Step 4 The Gas Supply Line 11 Step 5 Gas Pressure Requirements 12 Step...

Страница 4: ...in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada High Altitude Installations U L Listed...

Страница 5: ...trim surrounds are shipped in separate packages The gas logs are packaged separately and must be field installed Read all of the instructions before starting the installation Follow these instruction...

Страница 6: ...PARTS HAVE BEEN REPLACED AND THE FIREPLACE HAS BEEN REAPPROVED BY THE AUTHORITY HAVING JURISDICTION 4 The solid fuel fireplace s flue damper must be fully locked in the open position or removed for i...

Страница 7: ...SWITCH TOP VIEW 15 1 2 INCHES 27 3 4 INCHES MINIMUM FIREPLACE SIZE FRONT WIDTH 27 3 4 705mm REAR WIDTH 15 1 2 394mm DEPTH 9 229mm HEIGHT 22 559mm 9 Figure 1 Diagram of the BAY INS When planning a fire...

Страница 8: ...USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this manual Horizontal Venting The vent system on this model CANNOT be termin...

Страница 9: ...factory built woodburning fireplaces Connecting the Vent Pipe Install the 3 inch flexible vent pipes down through the chimney Attach and secure the bottom ends of the flex pipes to the starting colla...

Страница 10: ...2 FEET BELOW A HORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems installed on the outside of the building Roof Pitch H min ft flat to 6 12 1 0 6 12 to 7 12 1 25 over 7 12 to 8 12 1...

Страница 11: ...COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINATION CAP THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLET AIR COLLAR OF THE TERMIN...

Страница 12: ...9 Figure 4 Figure 5...

Страница 13: ...RNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The gas control systems used with this model is Standing Pilot Ignition Standing Pilot Ignition System This system includes millivolt control valve stand...

Страница 14: ...supply line A listed 1 2 inch 13 mm manual shut off valve and a listed flexible gas connector are connected to the 1 2 inch 13 mm inlet of the control valve A 1 8 inch 3 mm N P T plugged tapping acce...

Страница 15: ...in the center of the tap Position a rubber hose over the tap to obtain the pressure reading The fireplace and its individual shut off valve must be disconnected from the gas supply piping system durin...

Страница 16: ...the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace valve pigtails WARNING DO NOT CONNECT 110 120 VAC TO THE REMOTE W...

Страница 17: ...ON BOX FAN SPEED CONTROL RHEOSTAT Step 7 Installing Trim Logs and Ember Material Figure 9 Fan Wiring Diagram Installing the Trim Combustible materials MUST NEVER overlap onto the front face WARNING WH...

Страница 18: ...and removing from the unit Flip down the lower trim door Remove the wing nuts and glass clip at the top of the glass door Remove the glass door from the unit Cover the top of the burner with a single...

Страница 19: ...e unit 2 Remove the wing nuts glass clip and the glass door from the unit Figure 10 Glass Assembly CAUTION HAND TIGHTEN THE WING NUTS BUT BE CAREFUL NOT TO OVERTIGHTEN 1 Place the ember material onto...

Страница 20: ...mall amount of air will be in the gas supply lines When first lighting the fireplace it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the fireplace...

Страница 21: ...cedure at your next servicing For more information see Placing Ember Material in the INSTALLERS GUIDE Cleaning Once annually Qualified Brush or vacuum the control Burner Service compartment fireplace...

Страница 22: ...19 STANDING PILOT 3 8 10 mm Figure 12 Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING Figure 13 Pilot Ignitor Flame Patterns...

Отзывы: