Heat-N-Glo BAY-INS Скачать руководство пользователя страница 20

17

Step 8
Before Lighting
the Fireplace

Before lighting the fireplace, be sure to do the
following:

Review safety warnings and cautions

• Read the Safety and Warning Information section

at the beginning of this 

Installers Guide.

Double-check for gas leaks

• Before lighting the fireplace, double-check the unit

for possible gas leaks.

Double-check vent terminations and front grilles
for obstructions.

• Before lighting the fireplace, double-check the unit

for possible obstructions that could be blocking the
vent terminations or the front grilles.

Double-check for faulty components

• Any component that is found to be faulty MUST BE

replaced with an approved component. Tampering
with the fireplace components is DANGEROUS and
voids all warranties.

A small amount of air will be in the gas supply lines.
When first lighting the fireplace, it will take a few
minutes for the lines to purge themselves of this air.
Once the purging is complete, the fireplace will light
and will operate normally.

Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines, unless the
gas valve has been turned to the OFF position
, in
which case the air would have to be purged.

Step 9
Lighting the
Fireplace

You’ve reviewed all safety warnings, you’ve checked
the fireplace for gas leaks, you know the vent system
is unobstructed, and you’ve checked for faulty
components. Now you’re ready to light the fireplace.

WARNING
PLEASE REFER TO THE USER’S
MANUAL FOR ALL CAUTIONS, SAFETY,
AND WARNING INFORMATION
PERTAINING TO THE LIGHTING AND
OPERATION OF THE FIREPLACE.

After the
Installation

After the
Installation

LEAVE THIS INSTALLATION MANUAL
WITH THE APPLIANCE FOR FUTURE
REFERENCE.

Содержание BAY-INS

Страница 1: ...ITH APPLIANCE FOR FUTURE REFERENCE 1 This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes 2 This appliance is only for use...

Страница 2: ...PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should be CAREF...

Страница 3: ...Vent System 5 Vent System Approvals 5 Step 2 Positioning Leveling and Securing the Fireplace 10 Step 3 The Gas Control Systems 10 Step 4 The Gas Supply Line 11 Step 5 Gas Pressure Requirements 12 Step...

Страница 4: ...in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada High Altitude Installations U L Listed...

Страница 5: ...trim surrounds are shipped in separate packages The gas logs are packaged separately and must be field installed Read all of the instructions before starting the installation Follow these instruction...

Страница 6: ...PARTS HAVE BEEN REPLACED AND THE FIREPLACE HAS BEEN REAPPROVED BY THE AUTHORITY HAVING JURISDICTION 4 The solid fuel fireplace s flue damper must be fully locked in the open position or removed for i...

Страница 7: ...SWITCH TOP VIEW 15 1 2 INCHES 27 3 4 INCHES MINIMUM FIREPLACE SIZE FRONT WIDTH 27 3 4 705mm REAR WIDTH 15 1 2 394mm DEPTH 9 229mm HEIGHT 22 559mm 9 Figure 1 Diagram of the BAY INS When planning a fire...

Страница 8: ...USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this manual Horizontal Venting The vent system on this model CANNOT be termin...

Страница 9: ...factory built woodburning fireplaces Connecting the Vent Pipe Install the 3 inch flexible vent pipes down through the chimney Attach and secure the bottom ends of the flex pipes to the starting colla...

Страница 10: ...2 FEET BELOW A HORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems installed on the outside of the building Roof Pitch H min ft flat to 6 12 1 0 6 12 to 7 12 1 25 over 7 12 to 8 12 1...

Страница 11: ...COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINATION CAP THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLET AIR COLLAR OF THE TERMIN...

Страница 12: ...9 Figure 4 Figure 5...

Страница 13: ...RNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The gas control systems used with this model is Standing Pilot Ignition Standing Pilot Ignition System This system includes millivolt control valve stand...

Страница 14: ...supply line A listed 1 2 inch 13 mm manual shut off valve and a listed flexible gas connector are connected to the 1 2 inch 13 mm inlet of the control valve A 1 8 inch 3 mm N P T plugged tapping acce...

Страница 15: ...in the center of the tap Position a rubber hose over the tap to obtain the pressure reading The fireplace and its individual shut off valve must be disconnected from the gas supply piping system durin...

Страница 16: ...the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace valve pigtails WARNING DO NOT CONNECT 110 120 VAC TO THE REMOTE W...

Страница 17: ...ON BOX FAN SPEED CONTROL RHEOSTAT Step 7 Installing Trim Logs and Ember Material Figure 9 Fan Wiring Diagram Installing the Trim Combustible materials MUST NEVER overlap onto the front face WARNING WH...

Страница 18: ...and removing from the unit Flip down the lower trim door Remove the wing nuts and glass clip at the top of the glass door Remove the glass door from the unit Cover the top of the burner with a single...

Страница 19: ...e unit 2 Remove the wing nuts glass clip and the glass door from the unit Figure 10 Glass Assembly CAUTION HAND TIGHTEN THE WING NUTS BUT BE CAREFUL NOT TO OVERTIGHTEN 1 Place the ember material onto...

Страница 20: ...mall amount of air will be in the gas supply lines When first lighting the fireplace it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the fireplace...

Страница 21: ...cedure at your next servicing For more information see Placing Ember Material in the INSTALLERS GUIDE Cleaning Once annually Qualified Brush or vacuum the control Burner Service compartment fireplace...

Страница 22: ...19 STANDING PILOT 3 8 10 mm Figure 12 Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING Figure 13 Pilot Ignitor Flame Patterns...

Отзывы: