Heat-N-Glo BAY-INS Скачать руководство пользователя страница 2

SAFETY AND WARNING INFORMATION

READ and UNDERSTAND all instructions carefully before starting the installation.
FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard
and will void the warranty.

Prior to the first firing of the fireplace, 

READ the Using Your Fireplace section of the

Owners Guide.

DO NOT USE this appliance if any part has been under water. Immediately CALL a
qualified service technician to inspect the unit and to replace any part of the control
system and any gas control which has been underwater.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED by a qualified service person. The

appliance and venting system should be 

INSPECTED before initial use and at least

annually by a professional service person. More frequent cleaning may be required due
to excessive lint from carpeting, bedding material, etc. It is 

IMPERATIVE that the unit’s

control compartment, burners, and circulating air passageways 

BE KEPT CLEAN to

provide for adequate combustion and ventilation air.

Always 

KEEP the appliance clear and free from combustible materials, gasoline, and

other flammable vapors and liquids.

NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the
appliance 

CLEAR of all obstacles and materials for sevicing and proper operations.

Due to the high temperature, the appliance should be 

LOCATED out of traffic areas and

away from furniture and draperies. Clothing or flammable material 

SHOULD NOT BE

PLACED on or near the appliance.

Children and adults should be ALERTED to the hazards of high surface temperature
and should STAY AWAY to avoid burns or clothing ignition. Young children should be
CAREFULLY SUPERVISED when they are in the same room as the appliance.

These units 

MUST use one of the vent systems described in the Installing the Fireplace

section of the 

Installers Guide. NO OTHER vent systems or components MAY BE USED.

This gas fireplace and vent assembly 

MUST be vented directly to the outside and MUST

NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each
gas appliance 

MUST USE a separate vent system. Common vent systems are

PROHIBITED.

INSPECT the external vent cap on a regular basis to make sure that no debris is
interfering with the air flow.

The glass door assembly 

MUST be in place and sealed, and the trim door assembly

MUST be in place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE this appliance with the glass door removed, cracked, or broken.
Replacement of the glass door should be performed by a licensed or qualified service
person. 

DO NOT strike or slam the glass door.

The glass door assembly 

SHALL ONLY be replaced as a complete unit, as supplied by

the gas fireplace manufacturer. 

NO SUBSTITUTE material may be used.

DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to
clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It is recommended that a qualified
service technician perform an appliance check-up at the beginning of each heating
season.

Any safety screen or guard removed for servicing must be replaced before operating
this appliance.

!

!

!

!
!

!

!

!

!

!

!

!

!

!

!

!

!

!

i

Содержание BAY-INS

Страница 1: ...ITH APPLIANCE FOR FUTURE REFERENCE 1 This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes 2 This appliance is only for use...

Страница 2: ...PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should be CAREF...

Страница 3: ...Vent System 5 Vent System Approvals 5 Step 2 Positioning Leveling and Securing the Fireplace 10 Step 3 The Gas Control Systems 10 Step 4 The Gas Supply Line 11 Step 5 Gas Pressure Requirements 12 Step...

Страница 4: ...in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada High Altitude Installations U L Listed...

Страница 5: ...trim surrounds are shipped in separate packages The gas logs are packaged separately and must be field installed Read all of the instructions before starting the installation Follow these instruction...

Страница 6: ...PARTS HAVE BEEN REPLACED AND THE FIREPLACE HAS BEEN REAPPROVED BY THE AUTHORITY HAVING JURISDICTION 4 The solid fuel fireplace s flue damper must be fully locked in the open position or removed for i...

Страница 7: ...SWITCH TOP VIEW 15 1 2 INCHES 27 3 4 INCHES MINIMUM FIREPLACE SIZE FRONT WIDTH 27 3 4 705mm REAR WIDTH 15 1 2 394mm DEPTH 9 229mm HEIGHT 22 559mm 9 Figure 1 Diagram of the BAY INS When planning a fire...

Страница 8: ...USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this manual Horizontal Venting The vent system on this model CANNOT be termin...

Страница 9: ...factory built woodburning fireplaces Connecting the Vent Pipe Install the 3 inch flexible vent pipes down through the chimney Attach and secure the bottom ends of the flex pipes to the starting colla...

Страница 10: ...2 FEET BELOW A HORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems installed on the outside of the building Roof Pitch H min ft flat to 6 12 1 0 6 12 to 7 12 1 25 over 7 12 to 8 12 1...

Страница 11: ...COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINATION CAP THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLET AIR COLLAR OF THE TERMIN...

Страница 12: ...9 Figure 4 Figure 5...

Страница 13: ...RNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The gas control systems used with this model is Standing Pilot Ignition Standing Pilot Ignition System This system includes millivolt control valve stand...

Страница 14: ...supply line A listed 1 2 inch 13 mm manual shut off valve and a listed flexible gas connector are connected to the 1 2 inch 13 mm inlet of the control valve A 1 8 inch 3 mm N P T plugged tapping acce...

Страница 15: ...in the center of the tap Position a rubber hose over the tap to obtain the pressure reading The fireplace and its individual shut off valve must be disconnected from the gas supply piping system durin...

Страница 16: ...the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace valve pigtails WARNING DO NOT CONNECT 110 120 VAC TO THE REMOTE W...

Страница 17: ...ON BOX FAN SPEED CONTROL RHEOSTAT Step 7 Installing Trim Logs and Ember Material Figure 9 Fan Wiring Diagram Installing the Trim Combustible materials MUST NEVER overlap onto the front face WARNING WH...

Страница 18: ...and removing from the unit Flip down the lower trim door Remove the wing nuts and glass clip at the top of the glass door Remove the glass door from the unit Cover the top of the burner with a single...

Страница 19: ...e unit 2 Remove the wing nuts glass clip and the glass door from the unit Figure 10 Glass Assembly CAUTION HAND TIGHTEN THE WING NUTS BUT BE CAREFUL NOT TO OVERTIGHTEN 1 Place the ember material onto...

Страница 20: ...mall amount of air will be in the gas supply lines When first lighting the fireplace it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the fireplace...

Страница 21: ...cedure at your next servicing For more information see Placing Ember Material in the INSTALLERS GUIDE Cleaning Once annually Qualified Brush or vacuum the control Burner Service compartment fireplace...

Страница 22: ...19 STANDING PILOT 3 8 10 mm Figure 12 Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING Figure 13 Pilot Ignitor Flame Patterns...

Отзывы: