28
®
Link
Heat
Link
Pure
®
Link
Plus
Link
Pure
®
Link
Plus
Link
Pure
®
Link
Plus
F
S
F
S
Start
Finish
Sight
Hole
Improperly
positioned jaws
PEX
improperly
seated in
sleeve
Example Presses
1⁄2"
3⁄4"
1"
3. Move the cam lever to the Start and squeeze the
handles together.
4. Relax your grip on the handles to allow the Lever to be
moved to the next position - Large Diameter PEX may
take 2-4 press stages to complete
5. To complete a press, move the cam lever to the
Finish position and ensure that it will not move any
further. Failure to do so may result in a press out of
tolerance.
Squeeze to finalize the press.
6. Pull back on the moving
handle to open the jaws
and remove the tool from
the sleeve.
7. A properly positioned tool results in an accurate press: inspect the connection to
ensure the tubing is still seated in the sleeve (only PEX is visible in the sight hole), and
that a "W" press has been properly formed onto the sleeve. An improperly positioned
tool may result in a poor press and a damaged fitting.
Pinched sleeve; tool may be out
of calibration or damaged.