2

Installation, Operation & Maintenance 

VMH 30/36 SERIES

 

Heat Controller, Inc.

1)  Install according to this installation instructions strictly. If installation is defective, it will cause water

leakage, electrical shock fire, and may void the warranty.

     

 

 

 

.

2)  Use the manufacturer’s specified and supplied parts only

3)  Install in a strong and firm location which is able to withstand the unit’s weight. If the strength is 

     insufficient or installation is not properly done, the units can fall and cause injury.

4)  For electrical work, follow all local and National electrical codes  and these installation instructions. 

An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or a

       

 

 

 

 

 

   

   

 

 

   

 

 

 

defect found in electrical work, it may cause electrical shock or fire.

     

 

   

 

 

 

 

5)  Use the specified cable, connect tightly and clamp the cable so that no external force will be acted 

on the terminal. If connection is loose, it may cause excessive heat build up.

       

 

   

 

   

 

 

6)  Wiring routing must be properly arranged so that control board cover is fixed properly. If control board

cover is not fixed perfectly, it will cause heat build up at connection point of terminal, fire or electrical shock.

     

     

 

     

 

   

 

   

     

 

7)  When carrying out piping connection, take care not to let air substances other than the specified 

refrigerant go into refrigeration circuit. Otherwise, it will cause lower capacity, abnormal high pressure

     

   

 

 

 

   

 

 

 

 

 

 

 

in the refrigeration cycle, explosion and injury.

       

 

 

 

 

 

8)  Do not modify the length of the power supply cord or use an extension cord, and do not share the 

single outlet with other electrical appliances. Otherwise, it may cause fire or electrical shock.

     

 

 

 

 

 

 

 

 

   

 

1)  This equipment must be properly grounded and installed with and ground leakage current breaker, 

 electrical shock.

     otherwise it may cause

2)  Do not install the unit in place where leakage of flammable gas may occur. If gas leaks and 

     accumulates near or surroundings the unit, it may cause fire.

3)  Carry out drainage piping as mentioned in installation instructions. If drainage is not properly done,  

      water may enter the room and damage the furniture.

          The seriousness of safety precautions is classified by the following indications:

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to property.

SAFETY PRECAUTIONS

CAUTION

WARNING

CAUTION

WARNING

      Please read this installation manual completely before installing the product.

      If the power cord is damaged, replacement work shall be performed by authorized personnel only.

      Installation work must be performed in accordance with all local and national codes by authorized 

      personnel only. 

      Contact an authorized service technician for repair, maintenance or installation of this unit.

       

The design and specifications are subject to change without prior notice for product improvement. 

      Consult with the sales agency or manufacturer for details.

   

All the pictures in the instructions are for explanation purposes only, and may differ from the actual 

      product you purchased.

      

 

Содержание VMH 30 Series

Страница 1: ...ontroller Inc 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com INSTALLATION OPERATION MAINTENANCE MANUAL Inverter Single Zone Ductless Mini Split Heat Pump VMH 30 36 Series Vers...

Страница 2: ...LE IN THE WALL CONNECTIVE PIPE AND DRAINAGE INSTALLATION CONNECTING THE COMMUNICATION CABLE OUTDOOR SECTION OUTDOOR INSALLATION PRECAUTION DRAIN JOINT INSTALLATION REFRIGERANT PIPE CONNECTION CONNECT...

Страница 3: ...on cycle explosion and injury 8 Do not modify the length of the power supply cord or use an extension cord and do not share the single outlet with other electrical appliances Otherwise it may cause fi...

Страница 4: ...ndoor unit Outdoor unit If an awning is built over the unit to prevent direct sunlight or rain be careful that heat radiating from the condenser is not obstructed There should not be any animals or pl...

Страница 5: ...ith 2 55in 65mm hole core drill 3 Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side 4 Always use wall hole conduit when drilling metal g...

Страница 6: ...nsulate both the auxiliary piping Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Never intertwine th...

Страница 7: ...onditioner must be available 6 HCI recommends the use of 600V THHN 14 AWG 4 conductor unshielded stranded copper cable however NEC always prevails Electrical work Connect the cable to the indoor unit...

Страница 8: ...nt may very from the actual part that come with the unit Push the seal onto the end of the drain elbow connector Fig A then insert the drain elbow connector into the hole in the bottom of the base pan...

Страница 9: ...lbf 19 17 265kgf cm ft lbf Flaring Tightening connection U N I T Oblique O 90 Roughness Burr Bar Copper pipe Clamp handle Handle Bar A Indoor unit tubing Flare nut Pipings 4 1 Remove the electrical co...

Страница 10: ...gas side 2 Connect the charge hose connection to the vacuum pump 3 Fully open the handle of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose the flare...

Страница 11: ...e AUTO or COOL the unit will operate under Forced AUTO or COOL mode see User Manual for details 4 The manual test operation should last about 30 minutes giving the installing contractor an opportunity...

Страница 12: ...10 24 2012...

Отзывы: