background image

Heat Controller, Inc. 

Room Air Heat Pump with R-410A

 

Owner’s Manual

5

5

from outer case. Use both hands to grasp basepan and

pull remaining chassis from outer case.

PLASTIC FRONT

CHASSIS

BASEPAN

CLIP

NOTE:

 Basepan clip is shipped in plastic bag with mounting

screw and condensate drain cup. Install clip after reinserting

chassis into outer case to prevent accidental chassis removal.

General Operating Instructions

While operation of all units is similar, controls vary slightly

from model to model.

Operating Controls

section shows

control panel of unit purchased and gives detailed information

about operation of controls.

Initial Start-Up and Cooling

Select the highest fan speed and set temperature control to

its  coldest  position.    When  the  desired  temperature  is

reached,  slowly  move  the  temperature  control  toward  a

warmer setting until the compressor shuts off.  The thermo-

stat will then cycle the compressor on and off to maintain this

selected temperature.  Adjust the fan speed for desired air

circulation.

Changing Airflow Direction Baffles

Airflow on unit may be diverted left or right from center by

baffles. Upward and downward air discharge is provided by

tilting louvers. Adjust baffles and tilt louvers for desired

airflow pattern.

Airflow Around Unit

Check the indoor grille and outdoor louvers for obstructions to

airflow.  Do not block the airflow to and from the unit.  If air is

obstructed  and/or  deflected  back  into  the  unit,  the  air

conditioner’s compressor may cycle on and off rapidly.  This

could damage your unit.

OUTDOOR
LOUVERS

INDOOR
GRILLE

BAFFLES

Drain Cup Installation and Us

e

(on some models)  

Your air conditioner uses a system where the water removed

from the indoor air (condensate) is channeled to the outdoor

side of the unit.  The outdoor fan blade has a “slinger” ring

attached to it that dips into the water and slings the water onto

the outdoor coil surface.  This is the sound of water you hear

during normal operation.  The water quickly evaporates on

this warm surface and improves the efficiency of your air

conditioner.  In normal conditions the unit can evaporate the

water as fast as it is removed from the indoor air.
However, in very humid conditions excess amounts of water

may drip off the unit chassis.  If this proves to be a problem,

install the condensate drain cup included with the unit to

route excess water where it would not be a problem (see

illustration below).

To install, remove the unit chassis from the outer case.  Insert

the condensate drain cup through the recessed ½” hole on

the right side bottom flange of the outer case.  Once inserted,

place a ½” diameter hose or tube on the drain cup bottom

spout.  The hose allows you to route where you want the

excess water to go.  Reinsert the unit chassis into the outer

case.  The unit basepan overflow hole will be positioned

directly above the drain cup and will catch any water that

might run out.

1/2" Diameter

Hose

Condensate

Drain Cup

Outer Case

Switchover Thermostat Control

Emergency heat switch overrides heat pump (compressor)

and starts auxiliary electrical heater.  When switch is ON,

heat pump is locked out.

Use emergency switch 

only

 when heat pump fails to

provide adequate heat.  Cause of heat pump malfunc-

tion should be determined by authorized servicer.  Cost

of operating unit will increase when emergency heat

switch is engaged.

To access and engage emergency switch:

1. Remove front grille, air filter, and plastic front, as de-

scribed in Installation Instructions.

2. Remove basepan clip.
3. Slide chassis out of case about two inches.
4. Locate access hole for emergency switch above label on

right front of control box.

5. To start emergency heat, insert flathead screwdriver into

slot and turn counterclockwise until switch-stop is reached.

6. Return chassis to case.
7. Replace basepan clip, plastic front, air filter, and front

grille.

Содержание RAH-183G

Страница 1: ...Heat Controller Inc 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com OWNER S MANUAL Room Air Heat Pump with R 410A RAH 183G...

Страница 2: ......

Страница 3: ...Y PRECAUTION After installing unit reread instructions to ensure each step is complete and that all parts are fastened in place For best results and to minimize installation time perform all proce dur...

Страница 4: ...nse current leakage and can open the electrical circuit to the unit In the HIGH TEMPERATURE STRESS HAZARD This room air conditioner is not meant to provide unattended cooling or life support for perso...

Страница 5: ...the outdoor side of the unit s basepan is suggested in humid areas where algae formation is common Heat Controller Inc Room Air Heat Pump with R 410A Owner s Manual 3 3 NEMA No 5 15P NEMA No 5 15R 12...

Страница 6: ...ting efficiency of unit Filter should be inspected at least once every week during opera tion Cleanfilterwithvacuumcleanerorwashinwarmwater and mild detergent Filter should be thoroughly dried before...

Страница 7: ...hatdipsintothewaterandslingsthewateronto the outdoor coil surface This is the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficie...

Страница 8: ...he 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly g...

Страница 9: ...A 6 V support 2 Window locking bracket 2 Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 4 Type C 7 Type E Bolt 2 nuts 2 PARTS INCLUDED App...

Страница 10: ...2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securel...

Страница 11: ...ing rail Bottom frame guides INSTALL THE CASE IN THE WINDOW Carefully slide the case into the window and center the case Lower the window behind the top mounting rail Pull the bottom of the case forwa...

Страница 12: ...the wall Extend the left and right accordion panels to the vertical window sashes Drill pilot holes and attach the top and bottom corners with 4 type D screws F E D 6 Type D screw Type D screw Type D...

Страница 13: ...Unhook it from its top hinges and set it aside Using the tab pull up slightly on the filter to release it and pull it down and out F E D C B A 8 Installation Instructions INSTALL THE AIR CONDITIONER...

Страница 14: ...ds on the unit or the Increase Decrease pads on the remote control will set the delay time when using the Delay1 24hrtimer The Set light will turn on while setting Fan Speed Pads Use to set the fan sp...

Страница 15: ...erature cannot be entered The room temperature will appear in the display TIMER OFF When the air conditioner is on it can be set to automatically turn off in 0 5 to 24 hours How to set Press the TIMER...

Страница 16: ...a cooler room temperature Vent Control Choose one of the following two settings by sliding the vent control under the appropriate marking Exhausts room air to the outdoors Also circulates and filters...

Страница 17: ...of storm window frame before installation FROST ON INDOOR COIL Dirty air filter Normal for low outdoor temperatures Clean air filter by vacuuming or washing with water and mild soap Turning Temperatu...

Страница 18: ...Owner s Manual Room Air Heat Pump with R 410A Heat Controller Inc 16 This Page was Left Intentionally Blank...

Страница 19: ...Heat Controller Inc Room Air Heat Pump with R 410A Owner s Manual 17 This Page was Left Intentionally Blank...

Страница 20: ...04 2009 07 2010 66129905195...

Отзывы: