![Heat Controller MGD-B Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/heat-controller/mgd-b-series/mgd-b-series_owners-manual_2115735007.webp)
Heat Controller, Inc.
MGD-B SERIES GAS FURNACE
Owner’s Manual
PRE-TROUB
LESHOOTING CHECK LI
ST
YOU MUST HAVE THE FOLLOWI
NG TOOLS TO PREFORM THE
TROUBLESHOOTING
DESCRIBED
B
ELOW
:
1 - VOLT, AMP, OHM METER
VOLTAGE RANGE 0 - 300 VOLTS
VI
SE
GRI
P PLI
ERS
CURRENT RANGE 0.0 AMPS TO 1 MI
CROAMPS (
0.000001
AMPS)
. IF Y
OU CURRENT METER DOES NOT
HAVE A MI
CROAMP
(µa) READING;
mA.
YOU CAN USE THE MI
LLI
AMP
(mA)
PROVIDING
THE SCALE READS
0.000
G18D SERIES CONTROL
BOARD
TROUBLE SHOOTING GUIDE
8
G
1
8
D
S
e
ri
e
s
G
a
s
F
u
rn
a
ce
O
W
N
E
R
’S
M
A
N
U
A
L
M
or
te
x
P
ro
du
ct
s
In
c.
/
F
or
t W
or
th
, T
X
7
61
06
G
18
D
O
w
ne
r’s
M
an
ua
l
CO
N
DI
TI
O
N
FU
RN
A
CE
O
PE
RA
TI
O
N
DI
A
G
O
N
SI
C
LE
D
ST
EP
PR
O
BA
BL
E
CA
U
SE
O
F
PR
O
BL
EM
TR
O
U
BL
ES
HO
O
TI
N
G
SO
LU
TI
O
N
CA
LL
F
O
R
HE
A
T
FU
RN
A
CE
R
U
N
S
N
O
RM
A
LL
Y
ST
EA
DY
O
N
N
/A
N
/A
N
/A
BU
RN
ER
F
LA
M
E
CA
LL
F
O
R
HE
A
T
W
IL
L
N
O
T
ST
A
Y
LI
T
O
N
E
FL
A
SH
1
SE
N
SO
R
WI
RE
D
EFE
CT
IV
E
O
R
SE
N
SO
R
IS
BR
O
KE
N
.
U
SE
M
IC
RO
A
M
P
M
ET
ER
T
O
D
ET
ER
M
IN
E
IF
FLA
M
E
SE
N
SO
R
CU
RR
EN
T
RE
AD
IN
G
IS
BE
TWE
EN
1
.0
M
IC
RO
A
M
P
(0
.0
00
00
1
A
M
P)
A
N
D
3
.7
M
IC
RO
A
M
PS
(0
.0
00
00
37
AM
PS)
O
N
T
H
E
YE
LLO
W
WI
RE
. T
H
E
M
ET
ER
M
U
ST
B
E
CO
N
N
EC
TE
D
IN
S
ER
IE
S
BE
TWE
EN
T
H
E
FLA
M
E
SE
N
SO
R
A
N
D
T
H
E
CO
N
TR
O
L
BO
AR
D
. A
C
U
RR
EN
T
FLO
W
O
F
A
PP
RO
XI
M
A
TE
LY
3
.7
M
IC
RO
A
M
PS
WI
LL
BE
P
RE
SE
N
T
O
N
T
H
E
YE
LLO
W
SE
N
SO
R
WI
RE
WH
EN
TH
E
BU
RN
ER
FLAM
E
IS
PR
ESE
N
T
AT
T
H
E
FLA
M
E
SE
N
SO
R.
IF
T
HE
YE
LL
O
W
F
LA
M
E
SE
N
SO
R
W
IR
E
Q
U
ICK
CO
N
N
ECT
T
ER
M
IN
A
L
IS
CO
N
N
ECT
ED
A
N
D
THE
BU
RN
ER
F
LA
M
E
SE
N
SO
R
CU
RR
EN
T
RE
A
DI
N
G
IS
B
ET
W
EE
N
1
.0
-
3.
7
M
ICR
O
A
M
PS
(0
.0
00
00
1
- 0
.0
00
00
37
A
M
PS
) G
O
TO
S
TE
P
4;
IF
T
H
E
BU
RN
ER
FLA
M
E
SE
N
SO
R
CU
RR
EN
T
IS
N
O
T
RE
AD
IN
G
IS
BE
TWE
EN
1
.0
A
N
D
3
.7
M
IC
RO
A
M
PS;
T
H
EN
D
ISC
O
N
N
EC
T
TH
E
Q
U
IC
K
CO
N
N
EC
T
TE
RM
IN
AL
A
N
D
C
H
EC
K
TH
E
FLAM
E
SE
N
SO
R
CU
RR
EN
T
TO
GR
O
U
N
D
. I
F
TH
E
RE
A
D
IN
G
IS
N
O
T
BE
TWE
EN
1
.0
-
3.
7
M
IC
RO
A
M
PS
(0
.0
00
00
1
- 0
.0
00
00
37
A
M
PS)
T
H
EN
RE
PLA
CE
T
H
E
FLAM
E
SE
N
SO
R.
IF
TH
E
RE
A
D
IN
G
IS
BE
TWE
EN
1
.0
A
N
D
3
.7
M
IC
RO
AM
PS
TH
EN
GO
TO
ST
EP
2
.
2
SE
N
SO
R
WI
RE
D
IS
CO
N
N
EC
TE
D
O
R
SE
N
SO
R
WI
RE
IS
BR
O
KE
N
.
U
SE
M
IC
RO
A
M
P
M
ET
ER
T
O
D
ET
ER
M
IN
E
IF
FLA
M
E
SE
N
SO
R
CU
RR
EN
T
RE
AD
IN
G
IS
BE
TWE
EN
0
M
IC
RO
A
M
P
(0
.0
00
00
0
AM
P)
A
N
D
3.7
M
IC
RO
A
M
PS
(0
.0
00
00
37
A
M
PS)
O
N
T
H
E
YE
LLO
W
WI
RE
. I
F
YO
U
R
CU
RR
EN
T
M
ET
ER
D
O
ES
N
O
T
H
A
VE
A
M
IC
RO
A
M
P
RE
A
D
IN
G
YO
U
C
A
N
U
SE
TH
E
M
ILLIAM
P
PR
O
VI
D
IN
G
TH
E
SC
A
LE
R
EA
D
S
0.
00
00
00
A
M
PS.
T
H
E
M
ET
ER
M
U
ST
B
E
CO
N
N
EC
TE
D
IN
SE
RI
ES
BE
TWE
EN
T
H
E
FLA
M
E
SE
N
SO
R
AN
D
T
H
E
CO
N
TR
O
L
BO
A
RD
. A
C
U
RR
EN
T
FLO
W
O
F
A
PP
RO
XI
M
A
TE
LY
3
.7
M
IC
ROA
M
PS
WI
LL
BE
P
RE
SE
N
T
O
N
T
H
E
YE
LLO
W
SE
N
SO
R
WI
RE
WH
EN
TH
E
BU
RN
ER
FLAM
E
IS
PR
ESE
N
T
AT
T
H
E
FLA
M
E
SE
N
SO
R.
IF
TH
E
YE
LLO
W
FLA
M
E
SE
N
SO
R
WI
RE
Q
U
IC
K
CO
N
N
EC
T
TE
RM
IN
A
L
IS
CO
N
N
EC
TE
D
A
N
D
TH
E
BU
RN
ER
FLAM
E
SE
N
SO
R
CU
RR
EN
T
IS
N
O
T
RE
A
D
IN
G
IS
BE
TWE
EN
1
.0
A
N
D
3
.7
M
IC
RO
AM
PS
(0
.0
00
00
1
- 0
.0
00
00
37
A
M
PS)
WI
TH
T
H
E
CU
RR
EN
T
M
ET
ER
C
O
N
N
EC
TE
D
IN
SE
RI
ES
BE
TWE
EN
T
H
E
FLAM
E
SE
N
SO
R
A
N
D
T
H
E
CO
N
TR
O
L
BO
A
RD
; T
H
EN
U
N
PLU
G
TH
E
9
PI
N
P
LU
G
A
T
TH
E
CO
N
TR
O
L
BO
A
RD
A
N
D
P
ER
FO
RM
A
R
ESI
ST
A
N
CE
T
EST
(O
H
M
(
Ω
) T
EST
)
O
N
T
H
E
YE
LLO
W
FLA
M
E
SE
N
SO
R
WI
RE
. I
F
TH
E
O
H
M
S
(
Ω
) M
ET
ER
D
O
ES
N
O
T
IN
D
IC
A
TE
A
RE
A
D
IN
G
O
R
SH
O
WS
TH
E
∞
SY
M
BO
L
(SH
O
WS
A
O
PE
N
WI
RE
);
TH
EN
R
EP
LA
CE
T
H
E
FLA
M
E
SE
N
SO
R
WI
RE
O
R
TH
E
WI
RE
H
A
RN
ESS.
IF
TH
E
O
H
M
S
RE
A
D
IN
G
O
F
TH
E
SE
N
SO
R
WI
RE
IS
CLO
SE
T
O
Z
ER
O
O
H
M
S
TH
EN
GO
TO
ST
EP
3
.
3
TO
O
M
U
CH
D
RAF
T
CAU
SI
N
G
BU
RN
ER
F
LA
M
E
TO
LI
FT
A
WAY
FR
O
M
T
H
E
FL
AM
E
SE
N
SO
R
U
SE
A
M
P
M
ET
ER
T
O
D
ET
ER
M
IN
E
IF
FLA
M
E
SE
N
SO
R
CU
RR
EN
T
RE
A
D
IN
G
IS
BE
TWE
EN
1
.0
M
IC
RO
A
M
P
(0
.0
00
00
1
A
M
P)
A
N
D
3
.7
M
IC
RO
A
M
PS
(0
.0
00
00
37
A
M
PS)
O
N
T
H
E
YE
LLO
W
WI
RE
B
ET
WE
EN
T
H
E
SE
N
SO
R
AN
D
TH
E
CO
N
TR
O
L
BO
A
RD
WH
EN
T
H
E
BU
RN
ER
FLA
M
E
IS
PR
ESE
N
T
A
T
TH
E
FLA
M
E
SE
N
SO
R.
IF
TH
E
BU
RN
ER
FLA
M
E
SE
N
SO
R
CU
RR
EN
T
RE
A
D
IN
G
IS
N
O
T
BE
TWE
EN
1
.0
-
3.
7
M
IC
RO
AM
PS
(0
.0
00
00
1
- 0
.0
00
00
37
A
M
PS
) A
N
D
T
H
E
BU
RN
ER
WI
LL
N
O
T
ST
A
Y
LI
T
TH
EN
CA
FE
FU
LLY
B
EN
D
SE
N
SO
R
U
P
U
N
TI
L
TH
E
SE
N
SO
R
IS
IN
T
H
E
BU
RN
ER
FLAM
E
O
R
U
N
TI
L
FLA
M
E
SE
N
SO
R
M
IC
RO
A
M
PS
A
RE
B
ET
WE
EN
1
.0
-
3.
7
M
IC
RO
AM
PS
(0
.0
00
00
1
-
0.
00
00
03
7
A
M
PS)
.
U
SE
V
IS
E
G
RI
P
PL
IE
RS
T
O
HO
LD
SE
N
SO
R
RO
D
W
HE
N
BE
N
DI
N
G
FL
A
M
E
SE
N
SO
R
SO
T
HE
CE
RE
M
IC
DO
ES
N
O
T
BR
EA
K
O
R
CR
A
CK
.
IF
N
O
M
IC
RO
A
M
P
RE
A
D
IN
G
IS
PR
ESE
N
T
EV
EN
A
FT
ER
B
EN
D
IN
G
TH
E
SE
N
SO
R
U
P
TO
A
9
0
D
EG
RE
E
A
N
GLE
IN
FR
O
N
T
O
F
TH
E
BU
RN
ER
T
H
EN
R
EP
LA
CE
T
H
E
SE
N
SO
R.
IF
A
R
EA
D
IN
G
A
BO
VE
1
.0
M
IC
RO
AM
PS
IS
PR
ESE
N
T
BU
T
BU
RN
ER
WO
N
'T
ST
A
Y
LI
T
GO
T
O
ST
EP
4
.
4
TH
ER
E
IS
A
B
RO
KE
N
WI
RE
T
O
T
H
E
GAS
VAL
VE
O
R
O
N
E
O
F
TH
E
GAS
VA
LV
E
WI
RE
S
H
A
S
A
BAD
CO
N
N
EC
TI
O
N
.
U
SE
O
H
M
(
Ω
)
M
ET
ER
T
O
D
ET
ER
M
IN
E
WH
IC
H
WI
RE
T
O
T
H
E
GAS
VA
LV
E
IS
D
EFE
CT
IV
E AN
D REPLACE THE WIRES.
RE
M
O
VE
T
H
E
9
PI
N
P
LU
G
FR
O
M
T
H
E
CO
N
TR
O
L
BO
A
RD
A
N
D
T
H
E
WI
RE
S
FR
O
M
T
H
E
GAS
VALV
E.
U
SE
A
O
H
M
(
Ω
) M
ET
ER
T
O
D
O
A
R
ESI
ST
A
N
CE
T
EST
O
N
B
O
TH
O
F
TH
E
BR
O
WN
WI
RE
S
FR
O
M
T
H
E
PI
N
O
N
T
H
E
9
PI
N
P
LU
G
TO
T
H
E
GAS
VA
LV
E.
WH
EN
P
RE
FO
RM
IN
G
TH
IS
TE
ST
M
O
VE
T
H
E
WI
RE
H
A
RN
ESS
TO
C
H
EC
K
FO
R
A
B
AD
C
O
N
N
EC
TI
O
N
. I
F
A
C
O
N
N
EC
TI
O
N
IS
BA
D
T
H
E
M
ET
ER
R
EA
D
IN
G
WI
LL
CH
A
N
GE
FR
O
M
Z
ER
O
O
H
M
S
TO
SH
O
WI
N
G
O
PE
N
O
R
TH
E
IN
FI
N
IT
Y
(
∞
) SY
M
BO
L.
IF
A
WI
RE
IS
FO
U
N
D
T
O
B
E
D
EFE
CT
IV
E
O
R
H
A
S
A
B
AD
CO
N
N
EC
TI
O
N
; T
H
EN
R
EP
LA
CE
T
H
E
WI
RE
O
R
WI
RE
H
A
RN
ESS
. I
F
TH
E
BO
TH
W
IR
ES
A
RE
SH
O
WI
N
G
CLO
SE
T
O
Z
ER
O
O
H
M
S
(
Ω
) T
H
EN
GO
TO
ST
EP
5
.
5
CO
N
TR
O
L
BO
AR
D
IS
D
EFE
CT
IV
E
U
SE
A
M
IC
RO
AM
P
M
ET
ER
T
O
M
EA
SU
RE
T
H
E
FLA
M
E
SE
N
SO
R
CU
RR
EN
T
RE
AD
IN
G.
T
H
E
RE
AD
IN
G
M
U
ST
B
E
BE
TWE
EN
1
.0
M
IC
RO
A
M
P
(0
.0
00
00
1
AM
P)
A
N
D
3
.7
M
IC
RO
AM
PS
(0
.0
00
00
37
A
M
PS)
WI
TH
T
H
E
BU
RN
ER
FLA
M
E
PR
ESE
N
T
A
T
TH
E
SE
N
SO
R.
IF
TH
E
BU
RN
ER
FLA
M
E
SE
N
SO
R
CU
RR
EN
T
RE
A
D
IN
G
IS
BE
TWE
EN
1
.0
-
3.
7
M
IC
RO
A
M
PS
(0
.0
00
00
1
- 0
.0
00
00
37
A
M
PS)
A
N
D
T
H
E
BU
RN
ER
W
ILL
N
O
T
ST
A
Y
LI
T
TH
EN
R
EP
LA
CE
T
H
E
CO
N
TR
O
L
BO
A
RD
O
N
LY
IF
TH
E
CH
EC
KS
IN
ST
EP
S
1,
2,
3,
A
N
D
4
H
A
VE
B
EE
N
P
RE
FO
RM
ED
.
MGD-B SERIES CONTROL
BOARD
6
Содержание MGD-B Series
Страница 2: ...Owner s Manual MGD B SERIES GAS FURNACE Heat Controller Inc 1 ...
Страница 10: ...04 2009 07 2009 ...