7. Installation Details
7.1 Wrench torque sheet for installation
Outside diameter
Torque
Additional tightening torque
mm
inch
N
.
m
N
.
m
Ф6.35
1/4
15(153kgf.cm)
16(163kgf.cm)
Ф9.52
3/8
25(255kgf.cm)
26(265kgf.cm)
Ф12.7
1/2
35(357kgf.cm)
36(367kgf.cm)
7.2 Connecting the cables
The power wiring should always follow NEC and local codes, with respect to the unit’s, rating plate. See
installation manual for additional information. Main power connection is 208/230V/1PH~60HZ.
The communicating cable, which connects between the indoor and outdoor units must meet all NEC and
local codes, with respect to the unit’s rating plate. We recommend using 14 AWG/4 conductor Stranded THHN
6
Ф
Ф
V cable.
Pipe length and elevation
Unit
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas inch
(mm)
Liquid inch
(mm)
9K
3/8’’ (Ф9.5
2)
1/4’’ (Ф6.35)
(5)
16.5ft
(10)
3
3
ft
(15)
50ft
(20)
0.2 oz/ft
12K/18K
1/2’’ (Ф12.7)
1/4’’ (Ф6.35)
Max. Total length for all rooms
Dual-zone
(m)
Tri-zone
(m)
Quad-zone
(m)
(30)100ft
(45)150ft
(60)200ft
NOTES:
Capacity test is based on standard length and maximum allowance length is based on reliability.
Oil trap should be installed per (3-5 meters)10-15ft.
Outdoor connections are ¼” (
Ф
6.35 mm) liquid and 3/8” (
Ф
9.52 mm) gas, therefore a reducer is
provided with all 12/18k indoor sections.
2LOWUDS
,QGRRUXQLW
2XWGRRUXQLW
$
%
Содержание A-VMH18DC-1 Service
Страница 6: ...6 Service Manual VMH Series Heat Controller Inc 4 Wiring Diagram 4 1 A VMH18DC 1 4 2 A VMH27TC 1 ...
Страница 7: ...7 Heat Controller Inc VMH Series Service Manual 4 3 A VMH36QC 1 ...
Страница 47: ...47 Heat Controller Inc VMH Series Service Manual Appendix 4 ...
Страница 50: ...04 2009 10 2012 ...