10. Troubleshooting
10.1 Indoor Unit Error Codes
KEY:
☆
= Flashing Light X = Light is Off O= Solid Light is On
Operation
Timer
Display Error:
☆
1 time
X
E0
Indoor unit EEPROM parameter error
☆
2 times
X
E1
Communication Error between indoor and outdoor
unit
☆
3 times
X
E2
Zero-crossing signal detection error
☆
4 times
X
E3
Indoor fan speed is out of control
☆
5 times
X
E4
T1 Indoor room temperature sensor has an open
or short circuit
☆
6 times
X
E5
T2 Evaporator coil temperature sensor has an
open or short circuit
☆
7 times
X
EC
Refrigerant leakage detection error
☆
2 times
O
F1
T4 Outdoor temperature sensor has an open or
short circuit
☆
3 times
O
F2
T3 Condenser coil temperature sensor has an
open or short circuit
☆
4 times
O
F3
T5 Compressor discharge temperature sensor
has an open or short circuit
☆
5 times
O
F4
Outdoor unit EEPROM parameter error
☆
1 times
☆
P0
IPM malfunction or IGBT over-strong current
protection error
☆
2 times
☆
P1
Over voltage or over low voltage protection error
☆
3 times
☆
P2
High temperature protection of compressor top
☆
5 times
☆
P4
Inverter compressor drive error
Содержание A-DVC09SD-0
Страница 14: ...14 DVC DVH Inverter Mini Split Heat Controller B DVC24SD 1 B DVH24SD 1 ...
Страница 44: ...44 DVC DVH Inverter Mini Split Heat Controller P V P W ...
Страница 45: ...45 Heat Controller DVC DVH Inverter Mini Split P N ...
Страница 51: ...51 Heat Controller DVC DVH Inverter Mini Split This page is left intentionally blank ...