Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
62
About ON Mode
• All functions can be accessed when the remote control is
in the ON mode.
• Only active functions will be displayed when the remote
control is in the ON mode. For example: if the fan is the
only function that’s active, the fan icon and flame will be
the only icon shown in the display.
About OFF Mode
Only the following functions can be accessed in the OFF
mode:
• AUX1
• AUX2
Only active functions will be displayed when the remote
control is in the OFF mode.
Turning ON the Fireplace
• Press and hold the POWER button for 5 seconds to unlock
remote, back light will illuminate. Press the POWER button
again to turn the fireplace ON. The fireplace will first ignite
the pilot. The main burner will be lit, once the pilot flame has
been established. The remote will be locked again when
the fireplace is turned OFF.
NOTICE:
Whenever the fireplace is cycled from OFF to
ON, the main burner will light on high for 10 seconds before
returning to the previous user setting.
Adjusting Flame Height
• Press the
MENU
button to activate the menu.
• Using the
UP
and
DOWN
arrows highlight the
FLAME
icon and press
SELECT
.
• Use the
UP
and
DOWN
arrows to adjust the
FLAME
HEIGHT
, then press
SELECT
. The
FLAME HEIGHT
can
be adjusted to 5 different settings.
NOTICE:
FLAME HEIGHT will not be adjustable for first ten
seconds when fireplace is turned on.
NOTICE:
The system will remember the previous FLAME
HEIGHT setting and
will automatically adjust after 10
seconds.
Adjusting Fan Speed
• Press the
MENU
button to activate the menu.
• Using the
UP
and
DOWN
arrows highlight the
FAN
icon
and press
SELECT
.
• Use the
UP
and
DOWN
arrows to adjust the
FAN SPEED
,
then press
SELECT
. The
FAN SPEED
can be adjusted
to 3 different settings: HIGH, MEDIUM, LOW.
NOTICE:
The fan has a timer built into the control module.
After the fireplace is turned ON the timer will wait for 3 minutes
before turning on the fan. In addition, the fan will remain on
for 12 minutes after the fireplace has been turned OFF.
NOTICE:
Whenever the fan is turned ON, the FAN will start
up on the high setting for 10 seconds before adjusting to the
previous user setting.
AUx1 Function (Unit dependent Function)
• Press the
MENU
button to activate the menu.
• Using the
UP
and
DOWN
arrows highlight the
AUx1
icon
and press
SELECT
.
• Use the
UP
and
DOWN
arrows to adjust the
AUx1
output,
then press
SELECT
. The
AUx1
function
can be adjusted
to 4 different settings: HI, MED, LOW and OFF.
AUx2 Function (Unit dependent Function)
• Press the
MENU
button to activate the menu.
• Using the
UP
and
DOWN
arrows highlight the
AUx2
icon
and press
SELECT
.
• Use the
UP
and
DOWN
arrows to turn the
AUx2
ON
or
OFF
, then press
SELECT
. The
AUx2
function
can be
either be turned
ON
or
OFF
.
NOTICE:
When the fireplace is turned OFF both AUX1 and
AUX2 will be turned off. The AUX1 and AUX2 functions can
be activated from the remote’s OFF mode, when the flame
is off. When the fireplace is turned back ON, the AUX1 and
AUX2 settings will be restored to the previous setting.