Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
19
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due
to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY. Illustrations/diagrams are not
drawn to scale. Actual installation may vary due to individual
design preference.
Figure 5.1 Appliance Locations
D
H
Alcove
G
A
A
E
F
B
I
“A” measurement is from gas stove top, not side.
A
A
B
C
D
E
F
G
H
I
J
Inches
6
10
12
54
36
31
13
10-1/2
15-1/2
5
Millimeters
152
257
308
1372
914
781
337
267
394
127
Note: Mantel must maintain
1 in. (25 mm) clearance from
vertical flue.
C
C
J
I
J