This gas fireplace and vent assembly 

MUST 

be

vented directly to the outside and 

MUST NEVER 

be

attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance 

MUST USE

a separate vent system. Common vent systems are

PROHIBITED

.

INSPECT 

the external exhaust vent on a regular

basis to make sure that no debris is interfering with
the air flow.

The glass door assembly 

MUST 

be in place and

sealed, and the trim door assembly 

MUST 

be in

place on the fireplace before the unit can be placed
into safe operation.

DO NOT OPERATE 

this appliance with the glass

door removed, cracked, or broken. Replacement of
the glass door should be performed by a licensed
or qualified service person. 

DO NOT 

strike or slam

the glass door.

The glass door assembly 

SHALL ONLY 

be

replaced as a complete unit, as supplied by the gas
fireplace manufacturer. 

NO SUBSTITUTE 

material

may be used.

DO NOT USE 

abrasive cleaners on the glass door

assembly. 

DO NOT ATTEMPT 

to clean the glass

door when it is hot.

Turn off the gas before servicing this appliance. It is
recommended that a qualified service technician
perform an appliance check-up at the beginning of
each heating season.

Any safety screen or guard removed for servicing
must be replaced before operating this appliance.

DO NOT 

place furniture or any other combustible

household objects within 36 inches of the fireplace
front.

READ 

and 

UNDERSTAND 

all instructions carefully

before starting the installation. 

FAILURE TO

FOLLOW 

these installation instructions may result

in a possible fire hazard and will void the warranty.

Prior to the first firing of the fireplace, 

READ 

the

Using Your Fireplace section of the 

Owners Guide

.

DO NOT USE 

this appliance if any part has been

under water. Immediately 

CALL 

a qualified service

technician to inspect the unit and to replace any part
of the control system and any gas control which has
been under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED 

by a

qualified service person. The appliance and venting
system should be 

INSPECTED 

before initial use

and at least annually by a professional service
person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
material, etc. It is 

IMPERATIVE 

that the unit’s

control compartment, burners, and circulating air
passageways 

BE KEPT CLEAN 

to provide for

adequate combustion and ventilation air.

Always 

KEEP 

the appliance clear and free from

combustible materials, gasoline, and other
flammable vapors and liquids.

NEVER OBSTRUCT 

the flow of combustion and

ventilation air. Keep the front of the appliance

CLEAR 

of all obstacles and materials for servicing

and proper operations.

Due to the high temperature, the appliance should
be 

LOCATED 

out of traffic areas and away from

furniture and draperies. Clothing or flammable
material 

SHOULD NOT BE PLACED 

on or near the

appliance.

Children and adults should be 

ALERTED 

to the

hazards of high surface temperature and should

STAY AWAY 

to avoid burns or clothing ignition.

Young children should be 

CAREFULLY SUPERVISED

when they are in the same room as the appliance.

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

SAFETY AND WARNING INFORMATION

!

Содержание TWILIGHT

Страница 1: ...ppliance may be installed in an af termarket permanently located manufac tured mobile home where not prohibited by local codes 2 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Please contact your Heat N Glo Lifestyle Products dealer with any questions or concerns For the num...

Страница 2: ...OLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control whic...

Страница 3: ...ing the Fireplace 10 Step 3 Positioning Leveling and Securing the Fireplace 12 Step 4 The Gas Control System 13 Step 5 The Gas Supply Line 13 Step 6 Gas Pressure Requirements 13 Step 7 Wiring the Fireplace 14 Step 8 Finishing 15 Step 9 Installing Trim Logs and Ember Material 15 Installing the Trim 15 Positioning the Logs 15 Shutter Settings 15 Glass Specifications 16 Placing the Ember Material 16 ...

Страница 4: ...es numéros de pièce se trouve à la page suivante NG LP Exploded Parts Diagram GN PL Vue éclatée des pièces Service Parts Twilight Beginning Manufacturing Date 8 01 Ending Manufacturing Date ______ 4 8 5 12 13 11 9 Log Set Assembly 2 1 7 6 3 3 14 10 ...

Страница 5: ...oor Glass Assembly Assemblée de verre d intérieur GLA INDOOR 7 Indoor Door Assembly Assemblée de Porte D intérieur DF 36H 8 Hood Hotte SRV674 174 9 Log Set Assembly Sold as a Set Only Jeu de Bûches PRE 002253964 POST 002253964 LOGS MS LOGS TWILIGHT 10 Glass Clip Indoor Agrafe de Verre D intérieur 674 138 11 Glass Clip Outdoor Agrafe de Verre Extérieure 674 137 12 Insulation Board Conseil d Isolati...

Страница 6: ...4 Wire Assembly Module de fil 593 590A 5 Pilot Assembly NG Module de veilleuse GN 385 510A 5 Pilot Assembly LP Module de veilleuse PL 385 511A 6 Pilot Bracket Parenthèse Pilote 674 164 7 Burner Orifice NG 31C Orifice de brûleur GN 31C 582 831 7 Burner Orifice LP 1 8mm Orifice de brûleur PL 1 8mm 582 818 8 Valve Bracket Parenthèse de Valve 674 167 9 Flex Ball Valve Assembly Fléchir l Assemblée de S...

Страница 7: ...da These models may be installed in a bedroom or bed sitting room in the U S A and Canada High Altitude Installations U L Listed gas appliances are tested and approved with out requiring changes for elevations from 0 to 2 000 feet in the U S A and in Canada When installing this appliance at an elevation above 2 000 feet it may be necessary to decrease the input rating by changing the existing burn...

Страница 8: ...oid the owner s warranty and may present a fire hazard The Heat N Glo Lifestyle Products Warranty will be voided by and Heat N Glo Lifestyle Products disclaims any responsibility for the following actions Installation of any damaged fireplace Modification of the fireplace vent system Installation other than as instructed by Heat N Glo Lifestyle Products Improper positioning of the gas logs or the ...

Страница 9: ...S TOP GRILLE GLASS DOOR BOTTOM GRILLE GAS CONTROLS AND LABELS ELECTRICAL ACCESS GAS LINE ACCESS INDOOR OUTDOOR 8 1 2 13 2 43 1093 3 77 3 77 42 1068 4 40 3 4 1034 42 1 2 1080 17 7 8 453 24 1 8 611 23 3 8 595 8 204 36 1 8 917 7 8 204 40 1 2 1030 36 3 8 924 ELECTRICAL ACCESS GAS LINE ACCESS ...

Страница 10: ... shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING The clearance to the ceiling is measured from the top of the unit excluding the standoffs see Figure 9 The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the com bustible construction NOT from the scre...

Страница 11: ...R POSSIBLE TO USE THE VINYL PROTECTOR KIT O N P R Q FP See Note 1 See Note 1 See Note 2 QMIN RMAX Twilight 10 feet 2 x Q ACTUAL 1 additional termination cap Q 3 feet 1 x Q ACTUAL 2 additional termination caps Q 6 feet 2 3 x Q ACTUAL 3 additional termination caps Q 9 feet 1 2 x Q ACTUAL RMAX 2 caps plus fireplace x QACTUAL D E L FP A H M X J or K I A G F FP FP FP FP FP B B B 60 minimum for vinyl cl...

Страница 12: ...from side to side and front to back Shim the fireplace with non combustible material such as sheet metal as necessary Secure the fireplace to the framing byusing nails or screws through the nailing tabs See Figure 7 for placement of combustible housewrap or building paper and non combustible sheathing for the outside wall Combustible housewrap or building paper may be brought over the fireplace fl...

Страница 13: ... are connected to the 1 2 inch 13mm inlet of the control valve NOTE If substi tuting for these components please consult local codes for compliance Locate the gas line access hole in the outer casing of the fireplace The gas line may be run from either side of the fireplace provided the hole in the outer wrap does not exceed 2 in diameter and it does not penetrate the actual firebox Open the firep...

Страница 14: ... switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC TION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING WALL SWITCH RED BLK IGNITION MODULE 3 VAC TRANSFORMER 3 VAC BRN...

Страница 15: ...ugh space so that the bottom grille can be lowered and the trim door removed FOR OUTSIDE Marble brick tile stone or other non combustible materials can be used to cover up the gap between the facing material and the fireplace DO NOT obstruct or modify the air intake or exhaust Positioning the Logs If the gas logs have been factory installed they should not need to be positioned If the logs have be...

Страница 16: ... of the fireplace will not require this purging of air from the gas supply lines unless the gas valve has been turned to the OFF position in which case the air would have to be purged NOTE The fireplace should be run 3 to 4 hours on the initial start up Turn it off and let it cool completely Remove and clean the glass Replace the glass and run the fireplace for an additional 8 hours This will help...

Страница 17: ...replace s flame patterns Make sure the flames are steady not lifting or floating See Figure 15 The thermopile thermocouple tips should be covered with flame Checking Vent System Frequency Before initial use and at least annually thereafter more frequently if possible By Qualified service technician Home owner Task Inspect the external vent on a regular basis to ensure that no debris is interfering...

Отзывы: