Placing the Ember Material

Ember material is shipped with this gas fireplace. The bag
labeled Glowing Ember (050-721) is standard glowing em-
ber material.

To place the ember material:

Remove the wing nuts and glass clips around the glass
door.

Remove the glass door from the unit.

Place dime size pieces of ember material about 1/2 inch
apart near port holes in burner top. Do 

NOT

 press em-

bers into burner ports. Cover the top of the burner with a
single layer of ember material. For best performance do
NOT place embers on the ports at the rear of the burner.

Save the remaining ember materials for use during fire-
place servicing. The bag of embers provided is sufficient
for 3 to 5 applications.

Replace the wing nut, glass clips, and screws.

Replace the glass door and a front trim door on the unit.

Hand tighten the wing nut.

Figure 14.   Placement of the Ember Material

Step 10.  Before Lighting  the Fireplace

Before

 lighting the fireplace, be sure to do the following:

Remove all paperwork from underneath the fireplace.

Review safety warnings and cautions

• Read the 

Safety and Warning Information

 section at

the beginning of this 

Installers Guide

.

Double-check for gas leaks

• Before lighting the fireplace, double-check the unit for

possible gas leaks.

Double-check vent terminations and front grilles for

obstructions.

• Before lighting the fireplace, double-check the unit for

possible obstructions that could be blocking the vent ter-
minations or the front grilles.

Double-check for faulty components

• Any component that is found to be faulty 

MUST BE

 re-

placed with an approved component. Tampering with the
fireplace components is 

DANGEROUS

 and voids all war-

ranties.

A small amount of air will be in the gas supply lines. When
first lighting the fireplace, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the fireplace will light and will operate normally.

Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines,

 unless

 

the gas

valve has been turned to the OFF position

, in which

case the air would have to be purged.

NOTE:

 The fireplace should be run 3 to 4 hours on the initial

start-up. Turn it off and let it cool completely. Remove and
clean the glass. Replace the glass and run the fireplace for
an additional 8 hours. This will help to cure the products
used in the paint and logs.

!

!

Glass Specifications:

Side

Type

Outdoor

CERAMIC

Indoor

TEMPERED

Heat-N-Glo Lifestyle Products fireplaces manufactured with
tempered glass may be installed in hazardous locations
such as bathtub enclosures as defined by the CPSC. The
tempered glass has been tested and certified to the require-
ments of ANSI Z97.1-1984 and CPSC 16 CFR 1202. (Safety
Glazing Certification Council SGCC # 1595 and 1597.  Ar-
chitectural Testing, Inc. Reports 02-31919.01 and 02-
31917.01.)

This statement is in compliance with SPCS 16 CFR Sec-
tion 1201.5 “Certification and labeling requirements” which
refers to 15 USC 2063 stating “…Such certificate shall ac-
company the product or shall otherwise be furnished to any
distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass
with permanent marking in such locations. Glass meeting
this requirement is available from the factory. Please con-
tact your dealer or distributor to order.

Step 11.   Lighting the Fireplace

You’ve reviewed all safety warnings, you’ve checked the
fireplace for gas leaks, you know the vent system is
unobstructed, and you’ve checked for faulty components.
Now you’re ready to light the fireplace.

WARNING: PLEASE REFER TO THE USER’S
MANUAL FOR ALL CAUTIONS, SAFETY,  AND

WARNING INFORMATION PERTAINING TO THE
LIGHTING AND OPERATION OF THE FIREPLACE.

After the Installation

LEAVE THIS INSTALLATION MANUAL WITH
THE APPLIANCE FOR FUTURE REFERENCE.

During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the fireplace’s initial burning.

Содержание TWILIGHT

Страница 1: ...ppliance may be installed in an af termarket permanently located manufac tured mobile home where not prohibited by local codes 2 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Please contact your Heat N Glo Lifestyle Products dealer with any questions or concerns For the num...

Страница 2: ...OLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control whic...

Страница 3: ...ing the Fireplace 10 Step 3 Positioning Leveling and Securing the Fireplace 12 Step 4 The Gas Control System 13 Step 5 The Gas Supply Line 13 Step 6 Gas Pressure Requirements 13 Step 7 Wiring the Fireplace 14 Step 8 Finishing 15 Step 9 Installing Trim Logs and Ember Material 15 Installing the Trim 15 Positioning the Logs 15 Shutter Settings 15 Glass Specifications 16 Placing the Ember Material 16 ...

Страница 4: ...es numéros de pièce se trouve à la page suivante NG LP Exploded Parts Diagram GN PL Vue éclatée des pièces Service Parts Twilight Beginning Manufacturing Date 8 01 Ending Manufacturing Date ______ 4 8 5 12 13 11 9 Log Set Assembly 2 1 7 6 3 3 14 10 ...

Страница 5: ...oor Glass Assembly Assemblée de verre d intérieur GLA INDOOR 7 Indoor Door Assembly Assemblée de Porte D intérieur DF 36H 8 Hood Hotte SRV674 174 9 Log Set Assembly Sold as a Set Only Jeu de Bûches PRE 002253964 POST 002253964 LOGS MS LOGS TWILIGHT 10 Glass Clip Indoor Agrafe de Verre D intérieur 674 138 11 Glass Clip Outdoor Agrafe de Verre Extérieure 674 137 12 Insulation Board Conseil d Isolati...

Страница 6: ...4 Wire Assembly Module de fil 593 590A 5 Pilot Assembly NG Module de veilleuse GN 385 510A 5 Pilot Assembly LP Module de veilleuse PL 385 511A 6 Pilot Bracket Parenthèse Pilote 674 164 7 Burner Orifice NG 31C Orifice de brûleur GN 31C 582 831 7 Burner Orifice LP 1 8mm Orifice de brûleur PL 1 8mm 582 818 8 Valve Bracket Parenthèse de Valve 674 167 9 Flex Ball Valve Assembly Fléchir l Assemblée de S...

Страница 7: ...da These models may be installed in a bedroom or bed sitting room in the U S A and Canada High Altitude Installations U L Listed gas appliances are tested and approved with out requiring changes for elevations from 0 to 2 000 feet in the U S A and in Canada When installing this appliance at an elevation above 2 000 feet it may be necessary to decrease the input rating by changing the existing burn...

Страница 8: ...oid the owner s warranty and may present a fire hazard The Heat N Glo Lifestyle Products Warranty will be voided by and Heat N Glo Lifestyle Products disclaims any responsibility for the following actions Installation of any damaged fireplace Modification of the fireplace vent system Installation other than as instructed by Heat N Glo Lifestyle Products Improper positioning of the gas logs or the ...

Страница 9: ...S TOP GRILLE GLASS DOOR BOTTOM GRILLE GAS CONTROLS AND LABELS ELECTRICAL ACCESS GAS LINE ACCESS INDOOR OUTDOOR 8 1 2 13 2 43 1093 3 77 3 77 42 1068 4 40 3 4 1034 42 1 2 1080 17 7 8 453 24 1 8 611 23 3 8 595 8 204 36 1 8 917 7 8 204 40 1 2 1030 36 3 8 924 ELECTRICAL ACCESS GAS LINE ACCESS ...

Страница 10: ... shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING The clearance to the ceiling is measured from the top of the unit excluding the standoffs see Figure 9 The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the com bustible construction NOT from the scre...

Страница 11: ...R POSSIBLE TO USE THE VINYL PROTECTOR KIT O N P R Q FP See Note 1 See Note 1 See Note 2 QMIN RMAX Twilight 10 feet 2 x Q ACTUAL 1 additional termination cap Q 3 feet 1 x Q ACTUAL 2 additional termination caps Q 6 feet 2 3 x Q ACTUAL 3 additional termination caps Q 9 feet 1 2 x Q ACTUAL RMAX 2 caps plus fireplace x QACTUAL D E L FP A H M X J or K I A G F FP FP FP FP FP B B B 60 minimum for vinyl cl...

Страница 12: ...from side to side and front to back Shim the fireplace with non combustible material such as sheet metal as necessary Secure the fireplace to the framing byusing nails or screws through the nailing tabs See Figure 7 for placement of combustible housewrap or building paper and non combustible sheathing for the outside wall Combustible housewrap or building paper may be brought over the fireplace fl...

Страница 13: ... are connected to the 1 2 inch 13mm inlet of the control valve NOTE If substi tuting for these components please consult local codes for compliance Locate the gas line access hole in the outer casing of the fireplace The gas line may be run from either side of the fireplace provided the hole in the outer wrap does not exceed 2 in diameter and it does not penetrate the actual firebox Open the firep...

Страница 14: ... switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC TION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING WALL SWITCH RED BLK IGNITION MODULE 3 VAC TRANSFORMER 3 VAC BRN...

Страница 15: ...ugh space so that the bottom grille can be lowered and the trim door removed FOR OUTSIDE Marble brick tile stone or other non combustible materials can be used to cover up the gap between the facing material and the fireplace DO NOT obstruct or modify the air intake or exhaust Positioning the Logs If the gas logs have been factory installed they should not need to be positioned If the logs have be...

Страница 16: ... of the fireplace will not require this purging of air from the gas supply lines unless the gas valve has been turned to the OFF position in which case the air would have to be purged NOTE The fireplace should be run 3 to 4 hours on the initial start up Turn it off and let it cool completely Remove and clean the glass Replace the glass and run the fireplace for an additional 8 hours This will help...

Страница 17: ...replace s flame patterns Make sure the flames are steady not lifting or floating See Figure 15 The thermopile thermocouple tips should be covered with flame Checking Vent System Frequency Before initial use and at least annually thereafter more frequently if possible By Qualified service technician Home owner Task Inspect the external vent on a regular basis to ensure that no debris is interfering...

Отзывы: