background image

28

35035 Rev D

07/03

WARRANTY

FOR HEAT-N-GLO FIREPLACES

The limited warranty will not become effective until you have mailed the completed warranty card to:

Hearth & Home Technologies Inc., A DIVISION OF HON Industries

20802 Kensington Blvd., Lakeville, MN 55044.

This card must be mailed within 60 days of the fireplace installation.

Subject to the conditions set forth herein, HEARTH & HOME TECHNOLOGIES INC. (HHT) extends the following limited

warranty with respect to your Heat-N-Glo fireplace, excluding accessories, chimney components and glass doors.
If HHT is satisfied that any part or portion of the fireplace covered by this warranty is defective in material or workmanship

under normal use and service as described in the operating instructions, HHT will take the following actions:

1.

Within the first five (5) years from the date of installation, HHT shall, at its option, replace or repair any

such defect in material or workmanship, at HHT’s expense.  HHT  SHALL NOT BE RESPONSIBLE

FOR ANY OTHER LABOR COSTS, OR EXPENSES, INCLUDING INDIRECT, INCIDENTAL OR

CONSEQUENTIAL DAMAGES.

2.

During the sixth (6th) through the (10th) years after the date of installation, HHT shall supply replace-

ment parts or parts at no charge, but SHALL NOT BE RESPONSIBLE FOR ANY LABOR, TRANSPOR-

TATION, OR OTHER INDIRECT DAMAGES.

3.

During the eleventh (11th) through the fifteenth (15th) years after date of installation, HHT  will send to

you, FOB its factory, replacement parts (if available) at the current minimum wholesale price, but HHT

SHALL NOT BE RESPONSIBLE FOR ANY LABOR, TRANSPORTATION OR OTHER INDIRECT DAM-

AGES.

4.

During the first six (6) months after installation, HHT shall, at its option, replace or repair the glass

doors and  any electrical components, if operation is faulty.  (This does not include glass panels bro-

ken during shipment, misuse or careless handling.)  After the first six (6) months, HHT will sell to you,

FOB its factory, replacement parts at the current list price, but HHT SHALL NOT BE RESPONSIBLE

FOR ANY LABOR, TRANSPORTATION OR OTHER INDIRECT DAMAGES.  IF GLASS DOORS

OTHER THAN FACTORY DOORS ARE USED ALL WARRANTY AND LIABILITY ON THE FIREPLACE

IS VOIDED.

HHT may discharge its entire warranty liability by refunding the price of the product.
Products made by other manufacturers, sold with the fireplace or thereafter are not covered by this limited warranty.
This limited warranty will be void if the fireplace is not installed according to the installation instructions.  The limited warranty

also is void if the fireplace is not operated, at all times, according to the operating instructions furnished.  The limited warranty

will also be void if the fireplace is removed from the place originally installed.
EXCEPT TO THE EXTENT PROVIDED BY LAW, NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE, AND NO IMPLIED WARRANTIES SHALL APPLY TO THE FIREPLACE AFTER THE ABOVE LIMITED

WARRANTY HAS EXPIRED.
In states that do not allow limitations on how long implied warranty lasts, or do not allow exclusion of indirect damages, those

limitations or exclusions may not apply to you.  You may also have additional rights not covered in this limited warranty.
HHT reserves the right to make changes at anytime, without notice, in design, material, specifications and prices and the right

to discontinue styles and products.

• UNDERWRITERS LABORATORIES FILE NO. MH5850

Jan 2003

Содержание STS-42

Страница 1: ...ge Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier INSTALLATION OPERATING INSTRUCTIONS STS 42 OUTDOOR WOODBURNING FIREPLA...

Страница 2: ...ended In the event the home is unusually tightly sealed the optional combustion air kit may not provide all the air required to support combustion Hearth Home Technologies is not responsible for any s...

Страница 3: ...he illustrations and diagrams used throughout these installations instructions are not drawn to scale B DESCRIPTION OF THE FIREPLACE SYSTEM Figure 1 Typical Fireplace System A LISTINGS AND CODE APPROV...

Страница 4: ...a l B w e i V r a e l C s r o o D s s a l G d l o f i B B 2 4 8 1 M D s s a r B d e h s i l o P w e i V r a e l C s r o o D s s a l G d l o f i B S 2 4 8 1 M D l e e t S s s e l n i a t S w e i V r a...

Страница 5: ...z i l i b a t S y e n m i h C 0 3 1 1 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 5 S F t h g i a r t S p o t s e r i F 0 4 5 S F 0 3 p o t s e r i F 0 1 S A 4 2 d l e i h S n o i t a l u s n I...

Страница 6: ...n e l h t g n e l e v i t c e f f E s a h t i r e t f a t r a p y e n m i h c r e h t o n a o t d e p p a n s n e e b SL11 Chimney Stabilizer SL1130 Offset Return RF570 Roof Flashing Flat to 6 12 Pit...

Страница 7: ...v D 7 STS 42 INSTALLATION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR11 Round Termination Cap TR11T Round Telescoping Termination Cap ST1175 Square Termination Cap CT56 Chase Top CAK5A C...

Страница 8: ...lt if it is installed inside of the structure Figure 2 shows two typical installations Figures 3 and 4 show two typical installations assuming an outside air kit is being used Therefore an allowance m...

Страница 9: ...x 423 8 tall The finished cavity depth must be no less than 241 8 Figure 5 shows a typical framing using 2 x 4 lumber of the fireplace assuming combustible materials are used All required clearances...

Страница 10: ...far the chimney needs to be shifted to enable it to avoid the overhead obstacle See Figure 7 dimension A to determine chimney sections required to achieve the needed shift 2 After determining the offs...

Страница 11: ...e installation d Determine the number of firestop spacers stabi lizers roof flashing etc required to complete the fireplace installation 2 Chimney Height Requirements above roof line a Major building...

Страница 12: ...instructions for framing on pages 8 and 9 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Placing the Protective Metal...

Страница 13: ...ntil the top section meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney sec...

Страница 14: ...ulation shield should be installed when there is a possibility of insulation coming into contact with the factory built chimney system The insulation shield is installed by positioning it over the ver...

Страница 15: ...ppermost top section of pipe must extend 6 above the top of the chase collar to allow installation of the storm collar and termination cap See Figure 14 Figure 14 Installing a TR11 Round Termination C...

Страница 16: ...a standard feature with this fireplace and is required for safe operation Installation must be done at the time of initial construction The cooling air inlet tubes must be a minimum of 72 above the ba...

Страница 17: ...in this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure fire 13 Ga...

Страница 18: ...st be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are shown...

Страница 19: ...te slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn General Electric RTV103 Black or equivalent Rutland Inc Fireplace Mortar...

Страница 20: ...fire WARNING Detailed instructions for installation of the chase top storm collar and termination cap are packaged with these parts To avoid danger of fire all instructions must be strictly followed i...

Страница 21: ...n Fireplaces as well as other woodburning appliances have been used safely for many years It has been our experience that most problems are caused by improper installation and operation of the firepla...

Страница 22: ...ogies glass doors may be used See Figure 24 for proper glass door operation 4 Grate The factory installed integral grate must be used to hold the logs from falling out of an open fireplace and to allo...

Страница 23: ...s on the quality of the firewood you use All seasoned wood regardless of species contains about 8 000 BTU s per pound and hardwoods have a greater density than soft woods A piece of hardwood will cont...

Страница 24: ...e fireplace expansion and contraction will cause minor cracking of the refractory This is normal unavoidable and will not affect the perfor mance of the fireplace If the cracks become large enough tha...

Страница 25: ...If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yourself...

Страница 26: ...26 35035 Rev D 07 03 STS 42 INSTALLATION INSTRUCTIONS Homeowner s Notes...

Страница 27: ...3 Flue 21 Framing 9 Freestanding Installation 8 Fuel 23 G Gas Codes 17 21 Gas Log Lighter Provisions 17 General Information 21 Glass Doors 19 Grate 22 H Hearth Extension 18 Positioning 19 I Installati...

Страница 28: ...4 During the first six 6 months after installation HHT shall at its option replace or repair the glass doors and any electrical components if operation is faulty This does not include glass panels bro...

Отзывы: