5
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. B • 3/11
1.1 Locating the Heater
The diagram below shows space and clearance re-
quirements for locating a heater within a room.
Minimum Clearances
from the Heater to Combustible Materials
Figure 2. Heater Dimensions and Locations
For minimum clearances, see the direct fl ue termination
clearance diagrams on pages 6 and 7 in this manual.
Minimum Clearances
from the Flue Pipe to Combustible Materials
* The clearance to the ceiling is measured from
the top of the unit, excluding the standoffs (see
Figures 1 and 2).
The distance from the unit to combustible construction
is to be measured from the unit outer wrap surface to
the combustible construction,
NOT
from the screw
heads that secure the unit together.
mm inches
Glass Sides or Ends ..........914 ................... 36
Floor ....................................0 ......................0
Rear Flue ............................13 ................... 1/2
Metal Sides or Ends ...........13 ................... 1/2
Top ......................................64 ..................2-1/2
Ceiling* ..............................787 ...................31
mm
Inches
Vertical Sections
. ............. 25 ................. 1
Horizontal Sections
Top ..................................... 75 ................. 3
Bottom ............................... 25 ................. 1
Sides.................................. 25 ................. 1
At Wall Firestops
Top ..................................... 64 ..............2-1/2
Bottom ............................... 13 ............... 1/2
Sides.................................. 25 ................. 1
Clearance Requirements
The top, back, and sides of the heater are defi ned by
stand-offs. The minimum clearance to a perpendicular
wall extending past the face of the heater is 25 mm
(1 in.). The metal ends of the heater may
NOT
be
recessed into combustible construction.
914 mm
GLASS
GLASS
914 mm