Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. B • 3/11
Figure 18
B. Installing Flue Components
After determining which direction the 45º elbow will be
used follow fl ueing instructions accordingly.
• This heater requires the attachment of supplied 45º
elbow to unit before connection of fl ue components.
• To attach the elbow fl ue, the elbow cover plate must
fi rst be removed from the unit (see Figure 16).
• The elbow can be removed from the unit by aligning
the seams of the elbow to the arrows on the
surrounding heat shield (see Figure 17).
• Position the elbow in the horizontal or the vertical
position. Snap in place with the starting collar.
• Replace the elbow cover plate aligning it with the
elbow and secure in place with the 8 screws.
• Place the rope ring around the fi rst section of pipe
and slide it up against the cover plate.
Figure 16
ELBOW COVER PLATE
Figure 17
HEAT
SHIELD
ARROWS
ELBOW
ELBOW
SEAM
TOP VIEW
FRONT VIEW
NOTE
: The rope ring is needed for the heat manage-
ment and to prevent cold air infi ltration.
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
• Overlap pipe slip sections at least 1-1/2
inches (38 mm).
• Use pilot holes for screws.
• Screws must not exceed one inch
long.
• Pipe may separate if not properly
joined.