Heat & Glo • Soho-CE • 2111-900 Rev. i • 10/10
23
11
11
Finishing
A. Facing Material
Figure 11.1 Noncombustible Facing Diagram
Fire Risk.
Finish all edges and fronts to clearances and
specifi cations listed in manual.
• Black metal appliance front may be covered with
noncombustible material only.
• Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials up to specifi ed clearances
on top, front and side.
• Seal joints between the fi nished wall and appliance top
and sides using only a 150º C minimum sealant.
SEALANT MATERIAL
NON-COMBUSTIBLE ZONE
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
20.3 cm
74 cm
0 cm
0 cm
0 cm
B. Mantel Projections
No mantels are allowed when using Studio-CE fronts.
Risk of Fire
• Non-combustible clearances
MUST
be
maintained.
• Sheetrock, wood or other combustibles must
NOT
be used as sheathing or facing in the
non-combustible zone.
• See
Section 11
for proper clearances.
• See
Section 1
for combustible/non-combustible
defi nitions.
WARNING
WARNING
Figure 11.2 Minimum vertical and maximum horizontal
dimensions of combustibles above appliance
when using the DF-SOHOCE-BK dress guard.
12.7
17.8
10.2
OPENING OF FIREPLACE
7.6
12.7
20.3
30.5
5.1
22.9
25.4
27.9
15.2
2.6
40.7
15.2
17.8
20.3
22.9
25.4
27.9
30.5
33.0
35.6
38.1
Note: All dimensions are shown in centimeters