55
Heat & Glo • SOHO-B-CEB, SOHO-N-CEB, SOHO-P-CEB • 2111-980 Rev. i • 3/13
13
Finishing
Figure 13.3 Noncombustible Facing Diagram
SEALANT MATERIAL
NON-COMBUSTIBLE ZONE
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
20,3 cm
80 cm
0 cm
0 cm
0 cm
Figure 13.1 Minimum vertical and maximum horizontal
dimensions of combustibles above appliance
when using the DF-SOHOCE-BK front.
12,7
17,8
10,2
OPENING OF FIREPLACE
7,6
12,7
20,3
30,5
5,1
22,9
25,4
27,9
15,2
2,6
40,7
15,2
17,8
20,3
22,9
25,4
27,9
30,5
33,0
35,6
38,1
Note: All dimensions are shown in centimeters
B. Facing Material
• Facing and/or finishing materials must not interfere with
air flow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or finishing materials must never overhang
into the glass opening.
Combustible Mantels
No mantels are allowed when using Studio-CE fronts.
Combustible Mantel Legs or Wall Projections
Figure 13.2 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
UNLIMITED
TOP VIEW
7,3 cm
MINIMUM
1,3 cm
MINIMUM
• Observe all clearances when applying combustible
materials.
• Seal joints between the finished wall and appliance top
and sides using a 300 ºF (149 ºC) minimum sealant.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
A. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified. Framing or finishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).