55
Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. J • 3/13
BLUE
BROWN
GREEN/
YELLOW
BROWN
GREEN/YELLOW
BLUE
OPTIONAL FAN AND AUXILIARY BOX
Figure 12.2: Optional Fan Wiring Diagram
D. Blower
These fireplaces can use an optional Fan.
Use of the fan requires that the Junction Cord (factory
installed) be connected to 230 VAC service before per-
manently enclosing the fireplace. The access hole for
connecting the service wires is found on the right exterior
side of the unit. See Figure 12.3 for wire connection de-
tail.
Note:
if any of the original wire as
supplied with the appliance must be
replaced, it must be replaced with
type 105º C rated wire. Wires must
have high temperature insulations.
E. Control Module Operation
See Section 2.I for control module operation instructions.