Heat & Glo  •  SL-5/5LP-IFT, SL-7/7LP-IFT, SL-9/9LP-IFT Owner’s Manual  •  2632-981 Rev. D  •  1/21

3.5   Battery Pack Located in Control Cavity

NOTICE:  

Some functionality will be lost when using battery 

backup including fan, lights, or any other auxiliary functions 

that require household 110-120 VAC power.

J.  Operation During A Power Outage - IntelliFire Touch

®

The IntelliFire Touch intermittent pilot ignition system 

comes  with  a  battery  backup  system  that  enables  the 

system to operate in a power outage.  The system offers 

seamless transition from household AC power to battery 

backup. A factory-installed battery pack is located in the 

control cavity of the appliance. See Figure 3.5.  Battery 

longevity and performance will be affected by long term 

exposure to the service temperatures of this appliance.

NOTICE: 

Batteries should only be used as a power source 

in  the  event  of  an  emergency  power  outage.  Batteries 

should not be used as a primary long-term power source. 

Batteries tend to corrode over time.  

To Operate Fireplace Using Battery Power (DC):

1.  Access the control cavity of the appliance.  See Figure 

3.5 for location.  The decorative barrier front and front 

refractory may need to be removed. 

2.  Locate the battery tray and insert four AA cell batteries.  

Battery polarity must be correct or module damage 

will occur.  See Figure 3.5. A complete wiring diagram 

is included in the Electrical section of the appliance 

Installation Manual.

3.  Turn the appliance on according to the instructions 

below for the appropriate type of control:

Standard Wall Switch or Factory-Installed ON/OFF 

Switch: 

•   Toggle the switch as you would under normal 

circumstances.

Wireless Remote: 
•    Remote receiver is integrated into the ignition module
•    Use the remote to turn the appliance on.

•    To preserve battery life, do not use the HI/LO flame or 

THERMOSTAT options.  

Ignition Module:
•  Locate the ignition module in the control cavity.
•    Slide the ON/REMOTE/OFF switch to the ON position.

To Return to Operation Using Electrical (AC) Power

Standard Wall Switch or Factory-Installed ON/OFF 

Switch: 
•   Toggle the switch to OFF and remove the batteries 

from the battery tray.  Replace door or decorative 

barrier front on appliance.

Wireless Remote:
•   Slide the ON/REMOTE/OFF switch to the REMOTE 

position.  Remove the batteries from the battery tray.  

Replace door or decorative barrier front on appliance.

Ignition Module:
•   Slide the ON/REMOTE/OFF switch to the REMOTE 

position. 

  Remove the batteries from the battery tray.  Replace 

door or decorative barrier front on appliance.

BATTERY PACK

Содержание SL-5-IFT

Страница 1: ...rtible for use with other gases unless a certified kit is used DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at risk individuals DO NOT store or use gasoline or other flam mab...

Страница 2: ...n xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on control valve Total Electrical Requirements 120Vac 60Hz less than 12 Amperes MADE IN USA USA CANADA ALTITUDE 0 2000 FT 0 4500 FT MAX INPUT BTU h xx xxxx xx xxx MIN INPUT BTU h xx xxx xx xxx ORIFICE SIZE xx DMS xx DM...

Страница 3: ...ication 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall and Mantel Temperatures 8 E Good Faith Wall Surface TV Guidelines 8 F Before Lighting Appliance 10 G Lighting Instructions IPI 11 H Appliance Break In 12 I Heat Management 12 J Operation During A Power Outage IntelliF...

Страница 4: ...ent authorized HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances and 10 years from the beginning date of warr...

Страница 5: ...air supply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the applicable Product or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writin...

Страница 6: ...requirement is available from the factory Please contact your dealer or distributor to order This product is listed to ANSI standards for Vented Gas Fireplace Heaters and applicable sections of Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes Also Certified for Installation in a Bedroom or a Bedsitting Room NOT INTEN...

Страница 7: ...eplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire place for an extended period of time summer months vacations trips etc Remove batteries from remote controls Turn off wall controls Unplug 6 volt adapter plug IPI and remove batteries Set...

Страница 8: ...installed according to the installation instructions Non combustible surfaces and mantels do not have a maximum temperature limit however the installation instructions must still be followed for any restrictions on placement of non combustible materials on or around the fireplace Example The mantel above a fireplace in a room that is 70 F is allowed to reach but not exceed 187 F 70 F 117 F 187 F F...

Страница 9: ...d at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers maximum allowable operating temperatures identified in the TV s technical specifications Contact the TV s manufacturer directly if you cannot locate this information or have questions regarding the information 3 Mantel height and depth must conform to mantle requirements ...

Страница 10: ...ing materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NOT op erate firepl...

Страница 11: ...11 Heat Glo SL 5 5LP IFT SL 7 7LP IFT SL 9 9LP IFT Owner s Manual 2632 981 Rev D 1 21 G Lighting Instructions IPI ...

Страница 12: ...ed as desired may be installed with this appliance It may be either a Heat Zone Gas which diverts heat into an adjacent room and or a HEAT OUT GAS which will divert heat outside the home building Refer to Section 6 of the appliance installation manual to confirm which of the heat management systems may be installed together All heat management systems must be installed by a qualified service techn...

Страница 13: ... may need to be removed 2 Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 5 A complete wiring diagram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below for the appropriate type of control Standard Wall Switch or Factory Installed O...

Страница 14: ...N Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a wired wall switch IFT RC400 or IFT RC150 remote controls The IFT ECM switch must be in this position to pair the IFT ECM with the IFT ACM if installed and or IFT RC400 and IFT RC150 remote controls S...

Страница 15: ...FT RC400 IFT RC150 or wired wall switch to start the appliance appliance will ignite normally if the error condition was corrected If the IFT ECM re enters the lock out condition after these steps call your dealer for service Optional Fan Kit If desired a fan kit may be added Contact your dealer to order the correct fan kit Appliance ON OFF A wall control thermostat or remote control may be used t...

Страница 16: ...ming any of the listed tasks please call your dealer for a service ap pointment More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Any safety screen guard or barrier removed for servicing the appli ance must be replaced prior to operating t...

Страница 17: ...e remote control transmitter and receiver Verify operation of remote Refer to remote control operation instructions for proper calibration and setup procedure Replace batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your fireplace for an extended period of time summer months vacations trips etc to prevent unin tende...

Страница 18: ...voided Remove all foreign objects Verify unobstructed air circulation Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk broom flashlight voltmeter indexed drill bit set and a manometer Inspect orifice for soot dirt and corrosion Verify orifice size is correct See Service Parts List for proper orifice sizin...

Страница 19: ...Risk of Shock Label all wires prior to dis connection when servicing controls Wiring errors could cause improper and dangerous operation Verify proper operation after servicing WARNING Risk of Shock Replace damaged wire with type 105º C rated wire Wire must have high temperature insulation Figure 4 2 IPI Pilot Flame Patterns ...

Страница 20: ...eased from finishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing pro cess A non abrasive cleaner suc...

Страница 21: ...rmostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the remote the flame intensity will automatically decrease Au tomatic flame modulation will result in more control of the tem perature and will cause the appliance to cycle OFF ON less The appliance turns OFF the flame after extended periods of operation 9 hour safety sh...

Страница 22: ... ECM slider switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor out put voltage is between 5 7 6 3 Vdc If battery pack is used check battery pack voltage is 4 2 V if not replace batteries Shorted or loose connection in system wiring or wiring harness Verify system wiring configuration Remove and re...

Страница 23: ...o green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black wire i...

Страница 24: ...nal IntelliFire Wi Fi module with IntelliFire App After a qualified service technician has installed the In telliFire Wi Fi module with the IntelliFire app follow the instructions supplied to operate your appliance Contact your dealer if you have questions Remote Controls Wall Controls and Wall Switches After a qualified service technician has installed the remote control wall control or wall swit...

Страница 25: ...ributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Log Set Assembly Hearth Sold Separately LOGS SL5 Y 1 Rear Left Log SRV2391 707 2 Rear Right Log SRV2391 708 3 Burner Log SRV2391 709 4 Top Left Log SRV2392 711 5 Top Right Log SRV2391 710 6 Hearth Assembly Left Middle Right SRVHEARTH SL5 7 Drywall Support 2391 119 8 Burner Assembly 2391 007 Y 9 Valve Assembly See following page 10 Glas...

Страница 26: ... or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Log Set Assembly Hearth Sold Separately LOGS SL7 Y 1 Rear Left Log SRV2392 707 2 Rear Right Log SRV2392 708 3 Burner Log SRV2392 709 4 Top Left Log SRV2392 711 5 Top Right Log SRV2392 710 6 Hearth Assembly Left Middle Right SRVHEARTH SL7 7 Drywall Support 2392 119 8 Burner Assembly 2392 007 Y 9 Valve Assembly See following page...

Страница 27: ...r or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Log Set Assembly Hearth Sold Separately LOGS SL9 Y 1 Rear Left Log SRV2393 707 2 Rear Right Log SRV2393 708 3 Burner Log SRV2393 709 4 Top Left Log SRV2393 711 5 Top Right Log SRV2392 710 6 Hearth Assembly Left Middle Right SRVHEARTH SL9 7 Drywall Support 2393 119 8 Burner Assembly 2393 007 Y 9 Valve Assembly See following pag...

Страница 28: ...03 315 5 9 7 Jumper Wire SRV2187 198 Y 9 8 Thermostat Wire Assembly SRV2118 170 Y 9 9 Battery Pack SRV2326 134 Y 9 10 Module IFT Control SRV2326 130 Y 9 11 Wire Harness IFT 6 Pin SRV2326 132 Y 9 12 Component Tray 2279 185 9 13 6 Volt Transformer SRV2326 131 Y 9 14 Bulkhead w Flex Tube SRV7000 156 Y 9 15 Shutter Bracket Assembly 2118 121 Orifice NG 44C SL 5 IFT 582 844 Y Orifice Propane 55C 582 855...

Страница 29: ... your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Exhaust Baffle 550 155 Exhaust Restrictor 530 299 Finishing Template SL 5 IFT SRVFS 5 SL 7 IFT SRVFS 6 SL 9 IFT SRVFS 8 Gasket Assembly Contains Burner neck shutter bracket vent seal cap valve plate and air passage gaskets 2118 080 Mineral Wool 050 721 Touch Up Paint TUP GBK 12 CONVERSION KITS Conversion Kit NG SL 5...

Страница 30: ...__________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ DO NOT DI...

Отзывы: