62
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
SL-7X and SL-9X Models:
The rear left log will be
positioned to maintain about a
1/4 inch
rear gap be-
tween the rear left log and the back wall refractory.
There will be about a 1 inch side gap between the left
end of the log and left panel. See Figure 4.
SL-5X Models:
Locate the small notch on the back
left log pin and rotate the log back onto the back center
log pin. The rear left log will be positioned to maintain
about a
1/4 inch
rear gap between the rear left log and
the back wall refractory. There will be about a
1 inch
side gap between the left end of the log and the left
panel.
SL-3X Models:
The rear left log will be positioned to
maintain about a
1/4 inch
rear gap between the rear
left log and the back wall refractory. The rear left log
will contact the left refractory panel (no side gap). See
Figure 4.
Figure 4. Rear Left Log Installed
Install Glowing Embers
®
3. Remove the
Glowing Embers
®
from packaging and in
-
stall the ember material as shown in Figure 1. Care
should be taken to avoid placing ember material di
-
rectly over ports and to avoid using excessive amounts
of ember material.
Figure 5. Rear Right Log Installed
Install Rear Logs
1. Remove large rear left log from the packaging and install
the log by locating it on the back left log pin(s). The left
side of the log will reside within the indentation in the
left hearth component. See Figure 4.
Note:
SL-3X models do not utilize hearth indentations.
See Figure 4.
INDENTATIONS
INDENTATIONS
REAR GAP
REAR GAP
SIDE GAP
SIDE GAP
2. Remove the large rear right log from packaging and
install it by locating it on the back right log pin. On
some models, it may be necessary to lift the rear left
log slightly to install the rear right log. The right side
of the log will reside within the indentation in the right
hearth component. See Figure 5.
Note:
SL-3X models do not utilize hearth indenta
-
tions.
SL-7X and SL-9X Models:
The rear right log will be
positioned to contact the back wall refractory (no rear
gap). There will be about a 3/4 inch
side gap be-
tween the right end of the log and the right refractory
panel See Figure 5.
REAR GAP
REAR GAP
SIDE GAP
SIDE GAP
WARNING! Risk of Explosion!
Follow ember placement
instructions. DO NOT place embers directly over burner
ports. Replace ember material annually. Improperly
placed embers interfere with proper burner operation.
• Embers CANNOT be placed directly over ports. Care
should be taken not to cover the lighting trail of ports
(from back to front).
• When placing Glowing Embers
®
onto the burner care
should be taken so that the ports are not covered. Place
the dime-size ember pieces near the port holes in the
burner top. Failure to follow this procedure will likely cause
lighting and sooting problems.
SL-3X Models:
The rear right log will be positioned
to maintain about a 1 inch rear gap between the rear
right log and the back wall refractory. The rear right
log will contact the right refractory panel (no side
gap). See Figure 5. Slide the rear left log rightward
as close to the rear right log as the locating pin will
allow. There should be no more than a 1/4 inch
gap
between the rear logs.
SL-5X Models:
The rear right log will be positioned
to maintain about a
1/4 inch
rear gap between the
rear right log and the back wall refractory. The rear
right log will contact the right refractory panel (no side
gap). See Figure 5.