49
Heat & Glo • SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT Installation Manual • 2472-980 Rev. Q • 3/20
Electrical Service and Repair
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors could
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Component Tray
The electrical components are installed on the component
tray. If it becomes necessary to remove the components,
use the information in Figure 8.2 to remove them and
reinstall them correctly on the component tray.
The IFT-ECM is held in position by two placement tabs
(front and rear) and one plastic pin on the component
tray. To remove the IFT-ECM, bend the rear placement
tab back slightly and tip the IFT-ECM to disengage it
from the pin and the shorter placement tab. To reinstall
the IFT-ECM on the component tray, engage the front
placement tab first.
The LED controller is held in position by two placement
tabs and the four corner guides on the component tray. To
disengage the LED Controller, bend either placement tab
back slightly. Tip and lift the LED Controller out.
Note the orientation of the LED controller in Figure 8.2.
The LED controller must be positioned as shown with the
green, white and black wires toward the center of the tray.
The LED controller has a rounded profile on the top side
and a flat profile on the bottom side. Ensure it is positioned
correctly on the component tray.
IFT-ECM FRONT
PLACEMENT TAB
LED CONTROLLER
PLACEMENT TABS
PIN
GREEN/WHITE/BLACK WIRES
IFT-ECM REAR
PLACEMENT TAB
GUIDES
GUIDE
Figure 8.2. Electrical Component Tray