Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
22
H
1
INSTALLED
HORIZONTALLY
H
2
V
1
Figure 4.25
Top Vent - Horizontal Termination
- (continued)
Top Vent - Horizontal Termination
Venting with 2 elbows
Note
: Use DVP Series
components only.
V
1
Minimum
V
1
+ H
1
+ H
2
Maximum
2 ft.
610 mm
50 ft.
15.2 m
3 ft.
914 mm
60 ft.
18.3 m
4 ft.
1.2 m
70 ft.
21.3 m
V
1
+ H
1
+ H
2
= 70 ft. (21.3 m) Maximum
Note:
Must have 24 inches minimum
vertical vent prior to attaching any
elbow to the appliance.
Note:
PVI-DVP can be located in any
position except V
1
.
WARNING!
Risk of
fi
re and burns!
DO NOT install PVI-DVP with the
access panel facing upward.
Over-
heating may occur.