Heat & Glo  •  Escape-I35FB, Escape-I30FB  •  2201-900 Rev. K  •  5/11 

18

5

Fireplace Size Requirements 

 

Figure 5.1  Fireplace Opening

In addition to these dimensions, also reference 

Clearances and Mantel Projections (Section 5.B).

E

FRONT VIEW

D

C

F

A

TOP VIEW

B

G**

H

A.  Minimum Fireplace Opening

Minimum fi replace  opening  requirements  are  shown  in 

Figure 5.1. 

WARNING!  Risk  of  Fire  or  Burns! 

Provide adequate 

clearance around air openings and for service access. 

Due to high temperatures, the appliance should be locat-

ed out of traf

fi c and away from furniture and draperies.

•  The fi rebrick (refractory), glass doors, screen rails, screen 

mesh  and  log  grates  can  be  removed  from  a  factory 

built fi rebox in order to gain minimum gas insert opening 

requirements.

•  Any smoke shelves, shields and baffl es may be removed 

from the factory built fi rebox if attached with mechanical 

fasteners.

•  The metal fl oor of the solid fuel fi rebox may be removed to 

facilitate the installation of the insert.  The appliance may 

not be placed directly on the base of the outer wrap, a 1/4 

inch airspace must be provided between the insert and 

the fl oor of the outer wrap.  Use the levelling legs to raise 

the insert a minimum of 1/4 inch.  The original fi replace 

may  never  be  returned  to  solid  fuel  in  this  condition. 

The sidewalls and top structure of the fi rebox may not 

be altered with the exception of removable baffl es and 

dampers.

•  Cutting of any sheet metal parts of the fi replace in which 

the gas fi replace insert is to be installed is prohibited, 

except the fl oor as tested for and as noted above.

MINIMUM FIREPLACE SIZE

Location

ESCAPE-I35FB

ESCAPE-I30FB

Inches

Millimeters

Inches

Millimeters

A

Rear Width 

25-1/4

641

21-1/4

540

B

Front Width 

34-3/4

883

30

781

C

Glass Opening Width

31-1/2

800

26-3/4

679

D

Glass Opening Height

20

508

18

457

E

Height-Front

24-5/8

626

22-5/8

575

F

Height-Rear

22

559

20-3/8

517

G**

Unit Depth

18-1/4

464

16-7/8

429

H

Venting Depth

13-3/8

340

12-1/8

308

* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum 

fi replace height for bends in vent pipe. 

**Unit depth is measured to the back of the surround to give the depth needed for installation.

Содержание Escape-I30FB

Страница 1: ...use with the type s of gas indicated on the rating plate Installation and service of this appliance should be performed by quali ed personnel Hearth Home Technologies suggests NFI certi ed or factory...

Страница 2: ...c avec un un combustible combustible solide solide This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes codes if if any any if if n...

Страница 3: ...B Design and Installation Considerations 17 C Tools and Supplies Needed 17 D Inspect Appliance and Components 17 5 Fireplace Size Requirements A Minimum Fireplace Opening 18 B Mantel and Wall Projecti...

Страница 4: ...ginal purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT...

Страница 5: ...W RI QRUPDO XVH V D KHDWLQJ DSSOLDQFH VRPH FKDQJHV LQ FRORU RI LQWHULRU DQG H WHULRU VXUIDFH ILQLVKHV PD RFFXU 7KLV LV QRW D IODZ DQG LV QRW FRYHUHG XQGHU ZDUUDQW DPDJH WR SULQWHG SODWHG RU HQDPHOHG V...

Страница 6: ...ility or authorities having jurisdiction When installing above 2000 feet elevation In the USA Reduce input rate 4 for each 1000 feet above 2000 feet In CANADA Reduce input rate 10 for elevations betwe...

Страница 7: ...the xed glass panel DO NOT operate the appliance with the barrier removed Contact your dealer or Hearth Home Technologies if the barrier is not present or help is needed to properly install one HOT S...

Страница 8: ...or fronts may cause appliance to over heat This appliance has been supplied with an integral barrier to prevent direct contact with the xed glass panel DO NOT operate the appliance with the barrier r...

Страница 9: ...ion and in the event that the control goes into LOCK OUT mode as a result of an error code ON Position Appliance will ignite and run continuously in the HI ame setting with no adjustment in ame output...

Страница 10: ...Figure 2 7 Module Reset Switch MODULE RESET SWITCH 5 Module Reset Switch This module may lock out under certain conditions When this occurs the appliance will not ignite or respond to commands The mo...

Страница 11: ...ll settle on the oor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 22...

Страница 12: ...ed to burn for 20 to 40 minutes Odor from appliance When rst operated this appliance may release an odor for the rst several hours This is caused by the curing of the paint and the burning off of any...

Страница 13: ...equent cleaning may be required due to lint from carpeting or other factors The control compartment burner and circulating air passageway of the appliance must be kept clean CAUTION Risk of Burns The...

Страница 14: ...nician Tools needed Protective gloves vacuum cleaner dust cloths Vacuum and wipe out dust cobwebs debris or pet hair Use caution when cleaning these areas Screw tips that have penetrated the sheet met...

Страница 15: ...degradation due to long term heat exposure Check for smooth lighting and ignition carryover to all ports Verify that there is no ignition delay Inspect for lifting or other ame problems Verify air shu...

Страница 16: ...e not drawn to scale Actual product may vary from pictures in manual VERTICAL TERMINATION CAP SECTION 8 E VENT PIPE SECTION 8 GAS LINE SECTION 9 ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLAC...

Страница 17: ...in separate packages If packaged separately the log set and appliance grate must be installed Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of t...

Страница 18: ...laced directly on the base of the outer wrap a 1 4 inch airspace must be provided between the insert and the oor of the outer wrap Use the levelling legs to raise the insert a minimum of 1 4 inch The...

Страница 19: ...concrete board etc Clearance to combustible material under the insert is 1 4 inch 6 mm Clearance from top of replace opening for combustibles extending 12 inches max is 12 inches Use leveling legs to...

Страница 20: ...T MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 6 Termination Locations Fire Risk Maintain vent clearance to combustibles as speci ed DO NOT pack air space with insulati...

Страница 21: ...25 mm diameter or less may be drilled through the lower sides or bottom of the rebox in a proper workmanship like manner This access hole must be plugged with non combustible insulation after the gas...

Страница 22: ...ng is NOT allowed Vertical terminations are measured to top of chimney This appliance is listed for use with LINK DV systems and components only It is permissible to extend venting above existing chim...

Страница 23: ...ide plate to appliance by placing locking handle into position with locking tabs see Figure 8 1 and secure with 8 screw Level the appliance from side to side and front to back If necessary use the lev...

Страница 24: ...the LINK ZC ADPB with the self tapping screws provided OPTIONAL LINK ZC ADPB FOR USE WITH CLASS A WOODBURNING PIPE HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS...

Страница 25: ...lable leak check solution DO NOT use open ame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at...

Страница 26: ...fuel masonry or factory built replace to plug in the cord assembly or the supplied cord assembly may be rerouted out onto the hearth to a nearby outlet for proper operation of the appliance WARNING Ri...

Страница 27: ...ol module operation instructions F Installation for Fan Optional On appliances already installed removal of decorative front surround and gas insert is required 1 Remove appliance from wall 2 Disconne...

Страница 28: ...OWERS BLOWER RECEPTACLE BLK GRN BLK BLK GRN BLK WHT GRN BLK BLK GRN WHT BLK BLK PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTACLE Note use zip ties to restrain the loose wires underneath the appl...

Страница 29: ...te board etc Clearance to combustible material under the insert is 1 4 inch 6 mm Clearance from top of replace opening for combustibles extending 12 inches max is 12 inches Use leveling legs to raise...

Страница 30: ...nspection for cracking should be run when the appliance is cool Cracks tend to close as the appliance heats up D Clean the Appliance Clean vacuum any sawdust that may have accumulated inside the rebox...

Страница 31: ...cover the lighting trail of ports from back to front Place dime size pieces of Glowing Embers just in front of the port trail but not on or in between the ports See Figure 12 2 Escape I30FB or Figure...

Страница 32: ...rear burner ledge steps located on the bottom of the log on the burner ledge Slide the log forward until the burner ledge steps contact the vertical wall of the burner top Ensure the right side of th...

Страница 33: ...otate the left end of the log counterclockwise until it touches the grate tine Figure 8 Place Log 4 LOG TOUCHES SIDE OF FIREBOX GRATE TINE TOUCHES LOG GRATE TINE TOUCHES LOG Figure 11 Place Log 6 FLAT...

Страница 34: ...NER LEDGE BURNER LEDGE LIGHT HOLES SRV2202 705 SRV2202 706 SRV2202 702 SRV2202 703 SRV2202 701 SRV2202 704 LOG PINS Log 1 SRV2202 702 See Figure 2 for additional references Position Log 1 as shown in...

Страница 35: ...s the grate tine Figure 7 Log 3 Figure 8 Log 4 3 4 Figure 6 Log 2 Log 2 SRV2202 701 See Figure 2 and Figure 6 for additional references Position Log 2 as shown in Figure 5 Rest the rear step located o...

Страница 36: ...with the grate bar as shown above Swing the front end of the log to the left until it contacts log 3 5 6 PLACE LOG ON FLAT SPOT LOG 3 AND LOG 5 TOUCH FLAT SPOT FOR LOG 6 PLACE LOG ON FLAT SPOT PLACE L...

Страница 37: ...oken or scratched Replace as a complete assembly Removing Fixed Glass Assembly The glass assembly fastens to the replace in four places The fastening mechanisms are spring loaded glass latches An exam...

Страница 38: ...or 1 8 in 3 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly or depleted batteries Verify that transformer is installed and plugged into module Check vol...

Страница 39: ...e of pilot hood Flame sensing rod should glow shortly after ignition With a multi meter verify that cur rent in series between module and sense lead is at least 0 14 mi croamps Verify correct pilot or...

Страница 40: ...679 D 20 508 18 457 E 24 5 8 626 22 9 16 573 F 22 559 20 3 8 518 G 17 432 15 5 8 397 H 10 11 16 271 8 11 16 221 I 21 11 16 551 19 15 16 506 J 1 9 16 40 1 9 16 40 MODEL DIMENSIONS Location ESCAPE I35F...

Страница 41: ...Figure 14 3 Direct Vent Flex Liner Accessory Kits Direct Vent Flex Liner Accessory Kits see Figure 14 3 Flash Damp Zero clearance damper ashing kit for use with LINK DV 30B or LINK DV4 30B liner kits...

Страница 42: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Отзывы: