Clearance Requirements
The top, back, and sides of the heater are defi ned by standoffs.
The minimum clearance to a perpendicular wall extending past the face of the heater is
one inch (25 mm).
For 6000 Series Models, the back of the heater may be recessed 21-1/2 inches (546 mm)
into combustible construction.
For minimum clearances, see the direct fl ue termination clearance diagrams on page 7.
Minimum Clearances from the Heater to Combustible Materials
Glass
Front
Floor
Back of
Heater
Sides of
Heater
Top of
Heater
Ceiling
36 inches
914 mm
0
1/2 inch
13 mm
1/2 inch
13 mm
3-1/2 inches
89 mm
31 inches
787 mm
Minimum Clearances from the Flue Pipe to Combustible Materials
For Horizontal Sections
For Vertical
Sections
At Wall Firestops
Top
Bottom
Sides
Top
Bottom
Sides
3 inches
75 mm
1 inch
25 mm
1 inch
25 mm
1 inch
25 mm
2-1/2 inches
63.7 mm
1/2 inch
13 mm
1 inch
25 mm
REAR FLUE,
HORIZONTAL TERMINATION
TWO 90º ELBOWS
REAR FLUE
NO ELBOWS
REAR FLUE
ONE 90º ELBOW
ALCOVE
INSTALLATION
TOP FLUE
ONE 90º ELBOW
A
B
C
B
E
B
B
B
D
D
F
G
H
D
A
NOTE: THE REAR STANDOFF MAY NEED
TO BE REMOVED WHEN VENTING AT 45º
1,3 cm
I
C
L
A
B
C
D
E
F
G
H
I
6000
in.
51
42
72
56-5/8
See Section F.
Mantel Projections
22
17-3/4
8
28-3/4
mm
1295
1067
1829
1438
559
451
203
730
A. Locating the Heater
Figure 1.2