![Heat & Glo 6000PLUS Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/heat-and-glo/6000plus/6000plus_owners-manual_2115118010.webp)
Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05
13
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS TO PREVENT
ACCIDENTAL FIREPLACE OPERATION.
Wall Switch
Position the wall switch in the desired position on the wall.
An assembly of 18 ft of 20 AWG is provided with the fire-
place to connect the wall switch to the appliance. Instead of
the supplied assembly, wire with a length of 25 ft or less and
a gauge of 20 AWG through 14 AWG is acceptable. The
wire needs a jacket with a temperature rating of 140
o
F (60
o
C)
or higher. At the appliance connect the wire to the ON/OFF
switch pigtails.
!
Figure 7. Fan Wiring Diagram
WARNING: DO NOT CONNECT 110-120 VAC
TO THE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.
CAUTION: LABEL ALL WIRES PRIOR TO DISCON-
NECTION WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. VERIFY PROPER OPERATION AFTER
SERVICING.
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 C RATED WIRE.
O
JUNCTION BOX
VARIABLE SPEED CONTROL
TEMPERATURE
SENSOR SWITCH
WHT
GRN
BLK
BLK
110-120 VAC
BLOWER
BLOWER RECEPTACLE
BLK
BLK
BLK
BLK
WHT
GROUND
WHT
BLK
BLK
BLK
BLOWER
SENSOR
SWITCH
“FAN”
RECEPTACLE
SPEED
CONTROL