Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. B • 5/06
38
A. Mantel Projections
Figure 11.1 shows the minimum vertical and corresponding maxi-
mum horizontal dimensions of appliance mantels or other com-
bustible projections above the top front edge of the appliance.
Finishing
B. Facing Material
11
Figure 11.3 Noncombustible Facing
Fire Risk.
Finish all edges and fronts to clearances and
specifi cations listed in manual.
WARNING
• Black metal appliance front may be covered with
noncombustible material only.
• Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials only up to specifi ed clear-
ances on top, front and side.
• Seal joints between the fi nished wall and appliance top
and sides using only a 300
o
F minimum sealant.
Figure 11.2 Mantel Leg or Wall Projections
(Acceptable on both sides of opening.)
Figure 11.1 Clearances to Mantels or other Combustibles
above Appliance
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
•
Modifying or covering grilles could cause
temperature rise and fi re hazard.
WARNING
Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.
•
Operation of louvers or doors.
•
Access for service.
WARNING
Risk of Fire
• Non-combustible
clearances
MUST
be
maintained.
• Sheetrock, wood or other combustibles must
NOT
be used as sheathing or facing in the
non-combustible zone.
• See
Section 11
for proper clearances.
• See
Section 1
for combustible/non-
combustible defi nitions.
41 in.
39-3/8 in.
NON-COMBUSTIBLE ZONE (Shaded areas)
A
Top View
INTERIOR WALL
FIREPLACE
OPENING
B
MANTEL LEG OR WALL PROJECTIONS
Note:
All
measurements
in inches.
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters
62
87
113
138
164
189
B
Inches
1
2
3
4
5
∞
Millimeters
25
51
76
102
127
∞
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
NOTE:
Measurement is taken from top of the
opening, NOT the top of the fi replace.