Maximum Heat Output

  40,000 BTUs per 

hour of cordwood (based 
on independent laboratory 
test results) 

 

Size of Heated Area

  Up to 1,300 square feet. 

 

Firebox Capacity

 

1.5 cubic feet (.042 cubic 
meters) or 37.5 pounds of 
wood (The amount and 
weight of wood contained 
per cubic foot of firebox 
volume can vary from 15 
to 36 lbs. per cubic foot 
depending on type of 
wood, moisture content, 
packing density and other 
factors.  As a constant for 
comparison and test 
purposes, we are 
assuming 20 lbs. of 
seasoned hardwood per 
cubic foot of firebox 
volume).

 

 
 

 
 

Maximum Log Length

 17.5" 

(44.5 

cm) 

front door   

 

             Height

 26-1/8" 

(66.4 

cm) 

 
Width 

 

22-3/8” (56.8 cm) 

 

Depth

  

17-3/8" (44.1 cm) 

 

Front Door Size

  

19-3/4" wide x 
16-5/8" high (422 
x 349 mm) 

 

Stovepipe Size

 

6" (152 mm) 
diameter 

 

*Metal Chimney 

 

6" (152 mm) 
inside diameter 

 

*Masonry Chimney

 

8" x 8" (203 x 203 
mm) (square  flue) 

 

         Flue Exit

 Horizontal 

or 

Vertical  

 

Optional Equipment

 Outside 

Air 

Kit, 

Blower, 

    Rear 

Heat 

Shield

 

 

Содержание 8390

Страница 1: ...risk of fire follow the installation instructions Failure to follow these instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Craftsbury...

Страница 2: ...________________________________________________ Date of Purchase________________________________________________ Name of Dealer_________________________________________________ Address of Dealer_____...

Страница 3: ...em 12 Installing a Venting System 13 CONNECTING YOUR WOOD STOVE 13 Connecting to a Prefabricated Metal Chimney 13 Connection To A Masonry Chimney 16 INSTALLING IN A MOBILE HOME 17 OPERATING YOUR CRAFT...

Страница 4: ...other combustible surfaces This will help reduce the risk of fire Failure to follow these instructions can result in property damage bodily injury and even death Locate your stove in a safe convenient...

Страница 5: ...LC B 365 and the National Building Code for Canada If you are installing your Craftsbury in a mobile home follow the specific guidelines described in the Manufactured Home Construction and Safety Stan...

Страница 6: ...detector Keep a fire extinguisher handy We recommend the type rated A B C Dispose of ashes properly See page 23 Keep children and pets away from the stove they could be burned by touching a hot stove...

Страница 7: ...le inside the firebox is not packing and should not be removed from the stove prior to lighting see below HearthStone s Thermo Ceramic Baffle System To enhance the combustion efficiency and reduce the...

Страница 8: ...per cubic foot depending on type of wood moisture content packing density and other factors As a constant for comparison and test purposes we are assuming 20 lbs of seasoned hardwood per cubic foot of...

Страница 9: ...ctly in front of the stove need to be protected as described on page 10 Please use this section to plan how to locate your stove in your particular location Consider both the clearances of the stovepi...

Страница 10: ...sed by the stove for combustion is taken from outside of the residence rather than from within the room where the stove is located With outside air supplied directly to the stove drafts within the roo...

Страница 11: ...ORNER VIEW SIDE FRONT VIEW ALCOVE CLEARANCE TO COMBUSTIBLES WITH DOUBLE WALL PIPE AND REAR HEAT SHIELD Clearances Single wall connector Double walls connector With rear heat shield kit From unit Top c...

Страница 12: ...E SAFTY OF THE INSTALLATION VENTING CONFIGURATION COMPONENTS OF A VENTING SYSTEM The complete venting system will consist of several components chimney connector wall thimble wall pass through chimney...

Страница 13: ...eriodically inspection or clean the stovepipe connection and chimney Install the stove as close as practical to the chimney while maintaining all proper clearances Install stovepipe that is as short a...

Страница 14: ...stall with your stove be sure to also purchase from the same manufacturer all of the necessary components such as the wall pass through or ceiling support package T section package fire stops when nee...

Страница 15: ...ing ChimneySections ChaseEnclosure W allStrap SupportBox withbuilt in Starter AdjustableRoof Tee W allThimble Teeclean out Accessdoor TeeSupportBracket ChimneyissupportedbyTeeSupportBracket Chimneyiss...

Страница 16: ...te to the accumulation of creosote Use the following checklist to ensure that your masonry chimney meets these minimum requirements Chimney wall construction Brick or modular block at least 4 102 mm t...

Страница 17: ...ludes Stainless spark arrester cap storm collar Adjustable vented flashing 0 12 6 12 Two 24 Dura Plus chimney pipes 24 support box with built in starter section and trim UL or ULC approved equipment i...

Страница 18: ...ROL This feature is located on the lower left front of the stove under the ash lip The primary air control allows you to regulate the amount of air entering the firebox Generally speaking the more air...

Страница 19: ...Apple Black Birch Hickory Locust White Oak Black Beech Mesquite MEDIUM HIGH White Ash Beech Yellow Birch Sugar Maple Red Oak MEDIUM LOW Black Ash White Birch Grey Birch Elm Norway Pine Pitch Pine Blac...

Страница 20: ...bout ten pieces of very dry wood split to approximately 1 2 13 mm in diameter by roughly 10 254 mm long 2 Fully open the primary air control by pulling the lever fully out towards you 3 Light the pape...

Страница 21: ...s burning well use the primary air control to regulate the desired rate of burn Pulling the lever out away from the stove front opens the PRIMARY AIR CONTROL for a high rate of burn or pushing it unde...

Страница 22: ...ND DISPOSAL OF ASHES Ashes are best removed when the stove is cool In the morning before adding additional fuel is a good time for ash removal Use protective fireplace gloves when the pan is warm Exer...

Страница 23: ...ng system 2 After reloading with wood burn the stove with the primary air control fully open for 20 to 30 minutes This manner of operation ensures early engagement of the secondary combustion system w...

Страница 24: ...e to save hinge pins and washers for reuse Lay the door face down on a workbench or table Apply the cleaner to the glass and allow it to set for a few minutes By laying the door flat it will allow the...

Страница 25: ...st way to troubleshoot the problem is to monitor the temperature of the stack A 400 F 200 C stovepipe confirms the stove is supplying sufficient heat Keep in mind that your house itself will regulate...

Страница 26: ...ays This is a weather related phenomenon which generally is self correcting as the weather changes BRISKNESS OF FIRE The hotter the fire in your stove the hotter your chimney and therefore the stronge...

Страница 27: ...ently UNCONTROLLED OR SHORT BURN Unsealed or Open Door Close the front and ash doors tightly or replace the gaskets Excessive Draft Check the installation Operate at LOW BURN Install stovepipe damper...

Страница 28: ...0 PRIMARY AIR MANIFOLD 1 2310 970 FRONT 1 2310 975 DOOR 1 2310 980 SECONDARY AIR RISER 1 2310 985 SECONDARY AIR MANIFOLD BOTTOM ACCESSORIES 1 2310 987 SECONDARY AIR MANIFOLD TOP 93 68900 REAR HEAT SHI...

Страница 29: ...not connect this unit to a chimney flue serving another appliance NOTE Replace glass only with 4mm CERAMIC IR or NEOCERAM IR glass WARNING MOBILE HOME An outside air inlet must be provided for combust...

Страница 30: ...breakage and deterioration not resulting from physical damage or over loading of the Woodstove Firebox baffle the baffle above the secondary air tubes against breakage cracking or burn through Door h...

Страница 31: ...IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE GIVEN ONLY TO THE EXTENT REQUIRED BY FEDERAL OR STATE LAW EXCEPT AS OTHERWISE REQUIRED BY STATE...

Страница 32: ...e first ninety 90 days after the Purchase Date HearthStone will pay for the shipping of Woodstove parts covered by any of the foregoing warranties to and from HearthStone or a Dealer as the case may b...

Отзывы: