VS0952_E
12/30/2009
27
COMBUSTION
FAN
SPEED
ADJUSTMENT
(F1)
The
speed
of
the
combustion
fan
can
be
increased
or
decreased
by
adjusting
the
F1
Trimmer.
This
adjustment
allows
for
fine
tuning
of
the
combustion
fan
for
elevation
&
venting
during
initial
set
‐
up.
This
along
with
the
fresh
air
damper
(
See
Section
#4.11
“Adjusting
Air
Intake
Damper”
)
allows
you
to
fine
tune
the
amount
of
combustion
air
to
match
your
particular
installation.
Dur
‐
ing
normal
use
you
will
not
need
to
adjust
this
trimmer
as
the
damper
provides
sufficient
adjustability.
Turn
Clockwise
to
decrease.
Turn
counterclockwise
to
increase.
To
lower
the
fan
speed
turn
trimmer
clockwise
and
vice
versa
to
in
‐
crease
fan
speed
NOTE:
Trimmer
adjustment
affects
lowest
three
combustion
settings
only.
ITC
TEMPERATURE
ADJUSTMENT
(T1)
T1
is
the
ITC
temperature
trim.
This
allows
for
heat
setting
temperature
to
be
raised
or
lowered
to
meet
your
heating
needs.
Counter
clockwise
de
‐
creases
the
ITC
temperature
setting
and
clockwise
ITC
increases
the
tem
‐
perature
setting.
NOTE:
The
trim
pot
slot
is
made
of
plastic
and
can
be
damaged
or
stripped.
When
adjusting,
use
a
small
precision
screwdriver
with
non
‐
metallic
blade.
NOTE:
Trim
Pots
do
not
make
a
full
rotation.
Do
not
apply
extra
force,
damage
may
occur.
ADJUSTING
INTAKE
DAMPER
FOR
BEST
PERFORMANCE
A
HIGH
QUALITY
FIRE
should
burn
with
a
brisk,
vibrant,
yellow
to
white
color
flame.
When
watching
the
fuel
burn
in
the
grate,
you
should
see
a
slight
movement
of
the
embers.
However,
you
should
not
see
embers
whisked
out
of
the
burn
grate
from
high
velocity
intake
air.
A
flame
exhibit
‐
ing
a
lazy,
orange
or
sooty
characteristic
is
an
inefficient
flame.
This
type
of
flame
produces
less
heat,
increases
soot
and
smoky
exhaust.
Before
making
combustion
adjustments,
let
the
appliance
go
through
the
entire
START
‐
UP
procedure.
When
the
HEAT
LEVEL
LED
stays
solid,
turn
the
HEAT
LEVEL
to
the
#
2
setting
and
FAN
LEVEL
to
setting
#3.
Allow
the
appliance
to
run
on
this
setting
for
10
minutes
before
making
fine
adjustments.
Adjust
the
air
intake
damper
and
watch
the
burn
grate
and
flame
for
characteristics
as
described
above.
O
PERATING
I
NSTRUCTIONS
(C
(C
ONTINUED
ONTINUED
)
)
INCREASE
DECREASE
INCREASE
DECREASE
Damper
Rod
Содержание Hiawatha
Страница 13: ...VS0952_E 12 30 2009 13 EXHAUST SYSTEM CONTINUED PELLET VENT TERMINATION...
Страница 41: ...VS0952_E 12 30 2009 41 REPLACEMENT PARTS LIST...
Страница 42: ...VS0952_E 12 30 2009 42 REPLACEMENT PARTS LIST CONTINUED...
Страница 43: ...VS0952_E 12 30 2009 43 REPLACEMENT PARTS LIST CONTINUED...
Страница 44: ...VS0952_E 12 30 2009 44 REPLACEMENT PARTS LIST CONTINUED...
Страница 45: ...VS0952_E 12 30 2009 45 REPLACEMENT PARTS LIST CONTINUED...
Страница 46: ...VS0952_E 12 30 2009 46 REPLACEMENT PARTS LIST CONTINUED...
Страница 47: ...VS0952_E 12 30 2009 47 REPLACEMENT PARTS LIST CONTINUED...
Страница 48: ...VS0952_E 12 30 2009 48 REPLACEMENT PARTS LIST CONTINUED...