VS0952_E
12/30/2009
10
E
XHAUST
S
YSTEM
PELLET
VENT
TYPE:
⇒
Must
be
an
approved
3”
or
4”
Diameter
Type
”PL”
vent,
vented
to
the
outside
or
connect
the
vent
to
a
factory
built
type
“A”
chimney
using
an
adaptor.
⇒
Exception:
A
single
wall
“All
Fuel”
Stainless
Steel
chimney
liner
may
be
used
inside
a
fireplace
or
fire
‐
place
installations.
⇒
Some
venting
manufactures
do
make
“PL”
vent
for
use
with
wood
pellet
fuel
only
and
another
type
of
“PL”
vent
for
corn
or
bio
mass
fuels.
If
in
doubt,
plan
for
the
future
and
use
the
corn
or
multi
‐
fuel.
⇒
Use
4”
diameter
vent
if
vent
or
liner
height
is
over
15’
or
if
installation
is
over
3.000’
above
sea
level.
NOTE:
4”
diameter
vent
may
be
used
in
all
installations.
If
in
doubt,
use
4”
diameter
vent.
(See
diagram
on
Page
11.
)
VENT
SAFETY
PRECAUTIONS:
A
“Clean
Out
Tee”
(
A
)
must
be
installed
at
the
bottom
of
all
vertical
runs.
These
“Tee’s”
are
to
assist
in
periodically
cleaning
the
vent.
Single
or
Double
clean
out
tees
may
be
used.
The
exhaust
system
must
be
installed
so
the
entire
system
can
be
cleaned
without
disassembly.
Termination
must
exhaust
above
the
fresh
air
inlet
elevation,
and
parallel
or
above
the
exhaust
output
of
the
pellet
fuel
appliance.
It
is
highly
recommended
that
at
least
3
feet
of
vertical
pipe
(
B
)
be
installed
to
create
some
natural
draft.
This
is
to
help
prevent
the
possibility
of
smoke
or
odor
dur
‐
Ing
the
appliance
shut
down.
Horizontal
sections
must
have
a
1/4”
rise
every
12”
of
travel
after
3’
long.
Use
(3)
fastening
screws
per
joint.
Pellet
vent
connections
must
be
sealed
gas
tight.
Use
High
Temp
(550°F)
RTV
Silicone
or
Hi
‐
temp
Aluminum
foil
tape.
Seal
each
vent
section
by
injecting
a
liberal
amount
of
sealant
into
the
gap
or
wrap
with
foil
tape.
It
is
strongly
recommended
that
the
exhaust
system
be
terminated
on
the
prevailing
wind
side
of
the
home.
Appliance
may
not
be
placed
in,
or
vented
through
•
THE
PELLET
VENT
MUST
MAINTAIN
A
MINIMUM
3”
CLEARANCE
TO
ANY
COMBUSTIBLE.
•
(INSTALL
VENT
AT
CLEARANCES
SPECIFIED
BY
THE
VENT
MANUFACTURER).
•
DO
NOT
INSTALL
A
FLUE
DAMPER
IN
THE
EXHAUST
VENTING
SYSTEM
OF
THIS
UNIT.
•
DO
NOT
CONNECT
THIS
UNIT
TO
A
CHIMNEY
FLUE
SERVING
ANOTHER
APPLIANCE.
IMPORTANT
Содержание Hiawatha
Страница 13: ...VS0952_E 12 30 2009 13 EXHAUST SYSTEM CONTINUED PELLET VENT TERMINATION...
Страница 41: ...VS0952_E 12 30 2009 41 REPLACEMENT PARTS LIST...
Страница 42: ...VS0952_E 12 30 2009 42 REPLACEMENT PARTS LIST CONTINUED...
Страница 43: ...VS0952_E 12 30 2009 43 REPLACEMENT PARTS LIST CONTINUED...
Страница 44: ...VS0952_E 12 30 2009 44 REPLACEMENT PARTS LIST CONTINUED...
Страница 45: ...VS0952_E 12 30 2009 45 REPLACEMENT PARTS LIST CONTINUED...
Страница 46: ...VS0952_E 12 30 2009 46 REPLACEMENT PARTS LIST CONTINUED...
Страница 47: ...VS0952_E 12 30 2009 47 REPLACEMENT PARTS LIST CONTINUED...
Страница 48: ...VS0952_E 12 30 2009 48 REPLACEMENT PARTS LIST CONTINUED...