Hearthland Hiawatha Скачать руководство пользователя страница 1

VS0952_E

 

12/30/2009

 

   

 

 
 
 
 
 

 

 
 
 
 
 
 

 
 
 
 
 

 
 

 
 

SAFETY NOTICE 

PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF 

THIS PELLET FUEL-BURNING ROOM HEATER.  FAILURE TO FOLLOW THESE 

INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY 

OR EVEN DEATH.   

 

SAVE THESE INSTRUCTIONS.   

 

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS 

AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. 

WARNINGS 

• 

Hot! Do not touch! The glass and surfaces of this ap-
pliance will be hot during operation and will retain 

heat for a while after shutting off the appliance.  Se-

vere burns may result! 

• 

Hearthland pellet burning appliances are designed for 
use as a supplemental heater.  They are not intended 

for continuous use as a primary heat source. 

 

PELLET STOVE  

INSTALLATION AND OPERATION MANUAL

 

Hearthland Itasca 

Pellet Stove 

Hearthland Hiawatha 

Pellet Stove 

Hearthland Nokomis 

Pellet Stove 

Содержание Hiawatha

Страница 1: ...LATION INSPECTION REQUIREMENTS IN YOUR AREA WARNINGS Hot Do not touch The glass and surfaces of this ap pliance will be hot during operation and will retain heat for a while after shutting off the app...

Страница 2: ...it difficult to maintain proper combustion contributing to poor perform ance and increased fuel usage See Section 6 Maintenance Required Clean ing 4 Keep your stove s heat exchanger clean A dirty heat...

Страница 3: ...S 10 2 4 DETERMING VENTING SIZE DISTANCE 11 2 5 PELLET VENT TERMINATION 12 2 6 OUTSIDE AIR INTAKE 14 2 7 HEARTH PROTECTION CLEARANCES 15 2 9 REQUIREMENTS FOR FLOOR PROTECTION 15 2 10 MINIMUM CLEARANCE...

Страница 4: ...soline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use The...

Страница 5: ...om your stove before performing any maintenance Power Cord must be unplugged Pushing OFF Touch Pad does not disconnect all power to the stove To avoid accidental fire DO NOT place any flammable item o...

Страница 6: ...sted using the Fan Speed touch pad to run faster or slower to corre spond to the amount of heat being produced To turn off the stove simply pressing OFF on the touchpad and the unit will enter shutdow...

Страница 7: ...han one minute the unit will enter shut down mode This feature ensures that the stove will not operate with the door ajar or the ash pan tightened incompletely If this happens find and correct the cau...

Страница 8: ...tector Heating capacity will vary depending on such factors as the layout of your home air circulation degree of insulation and the outside temperature Pellet BTU content will affect the actual rate o...

Страница 9: ...n and measurements needed to install the stove in your chosen location _____ Pre fit all items before you install fasten or install the stove permanently _____ Make sure ALL joints of PL vent and sing...

Страница 10: ...e installed so the entire system can be cleaned without disassembly Termination must exhaust above the fresh air inlet elevation and parallel or above the exhaust output of the pellet fuel appliance I...

Страница 11: ...valent 90 Degree or Tee X 5 45 Degree X 3 Horizontal Pipe X 1 Vertical Pipe X 5 Total Equivalent Step 1 Complete table above Step 2 Ensure the Total Equivalent is or is less than 30 Step 3 Use the Siz...

Страница 12: ...ating on the side of the house Must not be located where snow or other mate rials such as leafs snow or grass could block it Must have a Metal Seal Plate or Wall Thim ble at point C Horizontal termina...

Страница 13: ...VS0952_E 12 30 2009 13 EXHAUST SYSTEM CONTINUED PELLET VENT TERMINATION...

Страница 14: ...de of a building Keep the outside air pipe termination at least 1 foot away from the exhaust system termination Keep the pipe termination clear of debris ice snow In spect the termination on a routine...

Страница 15: ...be made to en able sliding the appliance out MINIMUM CLEARANCE TO WALLS COMBUSTIBLES 2 From Back Of Stove 6 From Side of Stove 8 in Canada 6 From Front Of Stove 18 in Canada 16 From Top Of Stove 8 in...

Страница 16: ...VS0952_E 12 30 2009 16 HEARTH PROTECTION CLEARANCES CLEARANCES STRAIGHT THROUGH WALL INSTALLATION CLEARANCES INTERIOR VERTICAL INSTALLATION...

Страница 17: ...VS0952_E 12 30 2009 17 HEARTH PROTECTION CLEARANCES CONTINUED CLEARANCES 45 CORNER INSTALLATION CLEARANCES ALCOVE INSTALLATION...

Страница 18: ...bits Flashlight Hand Truck or cart for transporting stove to installation location Hammer Level Utility knife Adjustable pliers 6 to 8 inches Small hand broom and dustpan Furniture and Floor Protectio...

Страница 19: ...6 Place a bead of High Temp 550 F RTV silicone around the end collar of the Quick Connect of your stove s exhaust 3 Firmly push the PL vent pipe adaptor 4 into the bead of High Temp 550 F RTV silicon...

Страница 20: ...same basic steps in locating your appliance attaching the exhaust system and outside air intake to your stove as the previous examples INSTALLATION CONTINUED HEARTH STOVE EXISTING RELINE RAIN CAP STO...

Страница 21: ...ASS A ADAPTER 6 CEILING SUPPORT FIRESTOP SPACER 7 FLASHING STORM COLLAR 8 RAIN CAP 1 2 3 4 5 6 7 8 9 10 11 MAIN FLOOR TIE IN CLAYTILE FLUE 1 PL PIPE ADAPTER 2 PL CLEAN OUT TEE CAP 3 PL LENGTH OF PIPE...

Страница 22: ...ave a permanent outside air source with a inch screen over the inlet For transportation all chimney vent above the mobile home must be removed Chimney PL Vent must be 3 or 4 PL Vent and must extend a...

Страница 23: ...WARNING Make sure the stove has totally cooled down before touching the burn grate The Fuel Burn Grate comes in two pieces the burn grate A the burn pot top plate B To remove the Burn Grate grab the...

Страница 24: ...TC can be operated in one of three modes Manual Mode Factory default Thermostat ON OFF Mode Thermostat Modulated Mode High Low The touchpad has three functional but tons START HEAT LEVEL begins your s...

Страница 25: ...mode and enter burn mode The Igniter light will go out and the heat setting LED will stop flashing and stay on steady SHUTTING OFF STOVE 1 Press OFF on the touch pad and the following will happen The...

Страница 26: ...dicated in red on the HEAT LEVEL table Please note that the Enclosure Fan used to maintain internal component temperatures receives power only on HEAT LEVEL 4 SETTING FAN SPEED Room Heat Press FAN SPE...

Страница 27: ...tem perature setting NOTE The trim pot slot is made of plastic and can be damaged or stripped When adjusting use a small precision screwdriver with non metallic blade NOTE Trim Pots do not make a full...

Страница 28: ...s and hold the OFF button 2 While you are holding the OFF button the following cycle will occur 3 All four feed rate lights light solid 4 2 of the feed rate lights will flash indicating current operat...

Страница 29: ...FF touch pad per section 4 7 Starting Stove Shutting Off Stove Note If in THERMOSTAT ON OFF MODE the stove turns off and on frequently we suggest you turn the HEAT LEVEL to a lower setting so that it...

Страница 30: ...ncline of 1 8 mesh screen into a container or hopper This process will allow the good pellets to flow into the container while the fines fall through the mesh to be discarded PELLET CONSUMPTION With I...

Страница 31: ...mass of silica formed in the burning process Clinkering is a function of the fuel and not the stove however it adversely affects the performance of the stove by blocking off the air passages of the b...

Страница 32: ...d remove ash pan from stove Dispose ashes into a metal container with a tight fitting lid Before replacing ash pan inspect gasketing to ensure it is not damaged and will provide an air tight fit when...

Страница 33: ...ect in the exhaust venting system and restrict the flow of flue gases Incomplete combustion such as during startup shutdown or incorrect operation of the room heater will lead to some soot formation w...

Страница 34: ...nto the firebox will decrease the appliance s performance greatly leading to excessive soot and ineffi cient combustion If gasketing needs replacing use an OEM gasket This specifically designed gasket...

Страница 35: ...te burn box ash drawer and ash traps The exhaust system should be thoroughly cleaned Remove the Exhaust Manifold access panel and clean the exhaust manifold and the Combustion Blower blades and housin...

Страница 36: ...re goes out press STOP on the touch pad and add more fire starter re light the fire Press START and slowly close and latch the main door 8 The COMBUSTION FAN exhaust will start and operate at full spe...

Страница 37: ...SS PANELS REMOVED DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT WARNING HOT PARTS DO NOT OPERATE WITH SIDE OR REAR ACCESS PANELS REMOVED WIRING DIAGRAM Auger Motor 120 V 45 A 60...

Страница 38: ...RT touch pad Do any LED s light up Check the 9 pin wire connection to the board Inspect the board for any blown circuitry Before replacing check for the cause of the blown circuit It could be a shorte...

Страница 39: ...niter is not glowing Remove burn grate close door and re start the appliance If the igniter does not glow red inside the tube it is defective Remove back panel and confirm wire connec tions and condit...

Страница 40: ...e Protect venting from extreme weather elements Smoke or smoke smell spill age 1 Exhaust System Hi Heat RTV silicone all joints even manufactured Ensure venting is gas tight Inspect exhaust fan and ga...

Страница 41: ...VS0952_E 12 30 2009 41 REPLACEMENT PARTS LIST...

Страница 42: ...VS0952_E 12 30 2009 42 REPLACEMENT PARTS LIST CONTINUED...

Страница 43: ...VS0952_E 12 30 2009 43 REPLACEMENT PARTS LIST CONTINUED...

Страница 44: ...VS0952_E 12 30 2009 44 REPLACEMENT PARTS LIST CONTINUED...

Страница 45: ...VS0952_E 12 30 2009 45 REPLACEMENT PARTS LIST CONTINUED...