background image

7019-801C

July 10, 2019

4

SANTA FE PELLET INSERT

NOTE:

 Hearth & Home Technologies, manufacturer 

of this appliance, reserves the right to alter 

its products, their specifications and/or price 

without notice.

Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage.

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. 

Replace glass only with 5mm ceramic glass. Please 

contact your dealer for replacement glass.

D. Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

E. Mobile Home Approved

•  This appliance is approved for mobile home 

installations when not installed in a sleeping room and 

when an outside combustion air inlet is provided.

• 

The structural integrity of the mobile home floor, 

ceiling, and walls must be maintained.

•  The appliance must be properly grounded to the frame 

of the mobile home and use only Listed pellet vent 

Class “L” or “PL” connector pipe.

• 

Outside Air Kit, part OAK-ACC must be installed in a 

mobile home installation.

H. Sleeping Room

When installed in a sleeping room it is recommended that 

3ft of vertical be installed prior to horizontally exiting the 

room and a smoke/CO alarm be installed in the bedroom. 

The size of the room must be at least 50ft³ per 1,000 Btu/hr 

stove input, if the stove exceeds the room size, out air must 

be installed.

I. California - Prop65

WARNING

This product and the fuels used to operate this product (wood), and 

the products of combustion of such fuels, can expose you to 

chemicals including carbon black, which is known to the State of 

California to cause cancer, and carbon monoxide, which is known to 

the State of California to cause birth defects or other reproductive 

harm. For more information go to: WWW.P65Warnings.ca.gov

F. Non-Combustible Materials

Material which will not ignite and burn, composed of any 

combination of the following:

 - Steel

 - Plaster

 - Brick

 - Iron

 - Concrete

 - Tile

 - Glass

 - Slate

Materials reported as passing 

ASTM E 136, Standard 

Test Method for Behavior of Metals, in a Vertical Tube 

Furnace of 750° C. 

G. Combustible Materials

Material made of/or surfaced with any of the 

following materials:

 - Wood

 - Compressed Paper

 - Plant Fibers

 - Plastic

 -

Plywood/OSB

 - Sheet Rock (drywall)

Any material that can ignite and burn:

 flame proofed or not, 

plastered or non-plastered.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be 

voided by, the following actions: 

•  Installation and use of any damaged appliance. 

• 

Modification of the appliance.

•  Installation other than as instructed by Hearth & 

Home Technologies.

•  Installation and/or use of any component part not 

approved by Hearth & Home Technologies.

• 

Operating appliance without fully assembling 

all components.

• 

Operating appliance without legs attached (if 

supplied with appliance).

• 

Do NOT Over fire

 - If appliance or chimney connector 

glows, you are over firing.

Any such action that may cause a fire hazard.

Содержание Quadra-Fire SANTA FE SANTAFEI-C

Страница 1: ...iquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearance...

Страница 2: ...and Components 6 E Install Checklist 7 3 Dimensions and Clearances 8 A Appliance Dimensions 8 B Clearance To Combustibles UL and ULC 9 C Masonry Chimney and Fireplace Clearances 10 D Minimum Opening f...

Страница 3: ...800 to 22 400 hr BTU Input 9 300 to 30 600 hr Vent Size 3 4 L or PL or 6 inches Hopper Capacity 45 lbs Fuel Premium Wood Pellets Weighted average LHV Low Heating Value efficiency using data collected...

Страница 4: ...om size out air must be installed I California Prop65 WARNING This product and the fuels used to operate this product wood and the products of combustion of such fuels can expose you to chemicals incl...

Страница 5: ...ior to installation Installation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building inspector fire officials or authorities having jurisd...

Страница 6: ...ation to ensure maximum safety and benefit Follow pipe manufacturer instructions for installation and air clearance requirements C Tools And Supplies Needed Tools and building supplies normally requir...

Страница 7: ...ation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the a...

Страница 8: ...23 5 8 in 600mm 9 5 8 in 246mm 11 1 8 in 283mm 21 1 2 in 546mm 12 3 4 in 325mm 9 1 2 in 243mm 30 in 762mm 40 in 1016mm 14 5 8 in 373mm 9 7 8 in 250mm Figure 8 4 Front View with large basic panel set...

Страница 9: ...or protection The size of your floor protector choice must be added to this dimension 25 in 635mm 25 in 635mm 32 7 8 in 835mm 15 1 4 in 387mm NOTE Illustrations reflect typical installations and are F...

Страница 10: ...ng dimensions include a 1 4 6mm clearance around unit NOTE If trim measurement is over 3 4 in 19mm in depth use mantle or side clearances to combustibles Location Inches Millimeters A Height 23 1 4 59...

Страница 11: ...d 250 2061 WARNING THIS FIREPLACE MAY HAVE BEEN ALTERED TO ACCOMMODATE AN INSERT IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE 250 2061 Heath Home Technolo...

Страница 12: ...uilt zero clearance fireplace system must not be altered The flue liner top support attachment must not reduce the air flow for the existing air cooled chimney system No dilution air is allowed to ent...

Страница 13: ...and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in tabl...

Страница 14: ...and House demand may consume the air needed for the appliance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HVAC profe...

Страница 15: ...unted duct work and air handler joints and seams taped or sealed E Chimney and Exhaust Connection 1 Chimney Connector Use 3 or 4 inch 76 102mm diameter type L or PL venting system It can be vented ver...

Страница 16: ...his installation Figure 16 2 1 Locate the calculated equivalent feet of pipe on the vertical left side of the chart 2 Move to the right horizontally on the chart until you reach your altitude above se...

Страница 17: ...any edge to prevent future serviceability Fire Risk Inspection of Chimney Masonry chimney must be in good condition Meets minimum standard of NFPA 211 Factory built chimney must be a minimum 6 inch 15...

Страница 18: ...passage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES O...

Страница 19: ...N ULC S635 Standard for Lining Systems for Existing Masonry or Factory Built Chimneys and Vents or CAN ULC S640 Standard for Lining Systems for New Masonry Chimneys 12 305mm min below 12 305mm min abo...

Страница 20: ...ure 20 2 4 Slide trim ring over flex pipe and run pipe through wall 5 Attach hose to outside termination cap with second hose clamp 6 Secure termination cap to outside surface 7 Secure trim ring to in...

Страница 21: ...tape 6 Place cut edge of trim under top lip and into position on scissors Place side pieces on first and then front piece The front piece overlaps side pieces 7 Once you are satisfied with the positio...

Страница 22: ...each leg Figure 22 2 3 Open the hopper lid by pulling toward you This will make it easier to set the panels in place Secure the panels to the insert 2 screws per leg as shown in Figure 22 3 4 Connect...

Страница 23: ...wall anchors 4 Route the wires through the opening in the base plate and hold the base against the wall while aligning up to the holes Attach base plate using a Phillips head screwdriver and two screw...

Страница 24: ...firebox 4 Push the logs to the far left and far right against the sides of the firebox Figure 24 2 5 To clean the logs use a vacuum and a soft brush attachment or a paint brush Figure 24 2 Figure 24 1...

Страница 25: ...rd HUD CFR 3280 Part 24 PART NUMBER 811 0872 Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 25 1 CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HO...

Страница 26: ...7019 801C July 10 2019 26 SANTA FE PELLET INSERT 8 Reference Materials A Service Maintenance List Date of Service Performed By Description of Service...

Страница 27: ...7019 801C July 10 2019 27 SANTA FE PELLET INSERT Date of Service Performed By Description of Service...

Страница 28: ...7019 801C July 10 2019 28 SANTA FE PELLET INSERT Date of Service Performed By Description of Service...

Страница 29: ...7019 801C July 10 2019 29 SANTA FE PELLET INSERT Date of Service Performed By Description of Service...

Страница 30: ...kel SP SFI3040 NB Nickel SP SFI3040 NL Bracket L Trim 832 0840 Logo Quadra Fire Nickel 7000 649 10 Reset Button Assembly SRV7000 040 Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Programmab...

Страница 31: ...4 7000 157 24 Y Nut Wing 1 4 20 Pkg of 12 226 0110 12 Nut Wing 8 32 Pkg of 24 226 0160 24 Y Pin 3 16 X 1 2 7000 229 Rivet Iron 1 4 X 1 1 4 Pkg of 25 229 0090 25 Screw Flat Head 1 4 20 Pkg of 24 7000 1...

Страница 32: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...

Отзывы: