7019-801C
July 10, 2019
23
SANTA FE PELLET INSERT
G. Thermostat Installation
The kit comes with a programmable wall thermostat and
25’ of thermostat wire. If you need to run more than 25’
make sure you use a continuous strand of 18 to 22 gauge
thermostat wire. For optimum performance your thermostat
should be:
• Mounted on an inside wall, approximately 5’ above
the floor
• Do not locate where there is poor air circulation such
as in a corner, alcove, behind doors, bookcase or
other objects
• Located away from drafts, direct sunlight, above a
lamp, television, radiator, a wall next to a window, or
direct heat from the appliance
• Avoid damp environments as this can lead to corrosion
that may shorten thermostat life
• If painting or construction work around, cover the
thermostat completely or wait until work is complete
before installation.
Figure 23.1
1. Separate the body of the thermostat from the
mounting plate by gently pulling the two pieces apart
(Figure 23.1)
.
2. Use a drill with either a 3/16 drill bit for drywall or a 7/32
drill bit for plaster drill holes.
3. Using a hammer tap in wall anchors.
4. Route the wires through the opening in the base plate,
and hold the base against the wall while aligning up
to the holes. Attach base plate using a Phillips head
screwdriver and two screws.
5. Connect your thermostat wire to the W and R terminals
(Figure 23.2)
.
W
R
W
R
Appliance
BATTERY
BATTERY
NOTE:
Ensure bare wire ends are held ALL the way
into the terminal block while the screws are
being tightened.
6.
There are two AA ALKALINE ONLY batteries already
installed into the thermostat; to activate, remove
black plastic tab that is located inside the battery
compartment.
7. Snap the thermostat to the base plate.
Figure 23.2
Figure 23.3
Figure 23.3
Junction Box
Cut Away
LEFT SIDE
Junction Box, Front
Power
Cord
Recepticle
Terminal Block
Center 2 Screws
for Thermostat wires or remote
110 Outlet for
Remote
Control Only
(unfused)
Fuse
Red Call
Light
Connect thermostat wires to appliance:
There is a 4 screw terminal block located on the back
lower left corner of the stove directly above the power cord
inlet. The center 2 screws are for the thermostat wires
(Figure 23.3)
.
Shock hazard.
•
Do NOT remove grounding prong
from plug.
• Plug directly into properly grounded 3
prong receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front of
appliance.