![Hearth and Home Technologies Simplifyre SFE-26 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/hearth-and-home-technologies/simplifyre-sfe-26/simplifyre-sfe-26_homeowners-installation-and-operating-manual_2114489004.webp)
4
4050-308 Rev A 9/13/2007
WARNING
Do not use this fireplace if any part of it has been
under water. Immediately call a qualified service
technician to inspect and replace any of the
electrical system if necessary.
Carefully remove packaging from the unit. The front
screen is held in place with four Phillips head
screws. To remove the screen, extract the screws.
Grasp the screen frame and pull out.
ELECTRICAL SPECIFICATIONS
Voltage:
120 V AC, 60 Hz
Total Amps:
11.25 AMP
Total
Watts:
1350
Watts
Heater Rating: 1300 Watts/4415 BTU
LOCATING YOUR ELECTRIC FIREPLACE
Your new electric fireplace may be installed virtually
anywhere in your home. However, when choosing a
location ensure that the general instructions are
followed. For best results, install out of direct
sunlight.
Power supply service must be either completed or
placed within the heater prior to finishing to avoid
reconstruction.
Protective cover may stay on during framing, but
must be removed before final finishing. Once final
finishing has been completed, the protective cover
can be used to protect the heater until final
WARNING
: Do NOT connect the optional low voltage switch
and/or thermostat to 120 volt branch circuit.
The Optional Wall Switch 4050-309 contains two single pole
switches. ( LEVITON 5634 Series or equal)
The Optional Wall Thermostat is a low voltage mechanical type.
( Columbus Electric RK120EAA or equal).
Maximum run distance is 30’ with 20 gauge solid copper low
voltage thermostat wire. Connect per the Electrical wiring
diagram on page 7.
WALL SWITCH AND THERMOSTAT CONNECTIONS
CLEARANCE TO COMBUSTIBLES
Sides……………………0 inches 0 mm
Floor……………...…….0
inches
0 mm
Top…………………......0 inches 0 mm
Back…………………….0 inches 0 mm
FRAMING
1. Choose a fireplace location and frame as shown in
fig. 1
2. Frame in the fireplace with a header across the top.
3. It is important to allow for finished face when setting
the depth of the frame.
4. If a hearth system or raised hearth is to be
installed, The unit
MUST
be raised to provide
service access and use of optional fronts.
5. The fireplace can now be positioned in the opening.
6. Level it with shims if necessary, and attach the unit
to the frame using the nailing flanges provided.
HARDWIRE ELECTRICAL CONNECTIONS
Electrical wiring must comply with local building codes and
other applicable regulations to reduce the risk of fire, electrical
shock and injury .
NOTE:
All wiring must be completed prior to finishing the unit.
For supply connections use No. 14 AWG or larger wires.
Use copper wire only. Connect only to a 15 AMP branch circuit.
A dedicated circuit is recommended as other appliances on the
circuit may cause the breaker to trip or fuse to blow when the
heater is operating.
1. Remove the screws securing the junction block cover.
2. Wire to a properly grounded, 120 volt, 60 Hz, 15 AMP circuit
3. Ensure all junction block connections are tight.
4. Replace the cover and retaining screws.
5. Plug in the IEC-320-C14 power plug to the IEC-320-C13
power inlet located on the upper right side of the unit.
6. All components and wiring may be inspected by removing
the top inter-panel through the fireplace front opening.
FINISHING
Combustible or non-combustible materials may be used to finish
up to the fireplace opening.
NOTE:
Ensure that you leave adequate room to remove and replace the
front screen or optional front.
UNPACKING THE UNIT
Содержание Simplifyre SFE-26
Страница 9: ...9 4050 308 Rev A 9 13 2007...