background image

39

Quadra-fire  •  QV32B-A, QV36B-A  •  2014-900  Rev. F  •  9/06

Step 12.   Lighting the Appliance

STANDING PILOT IGNITION

A. This appliance (standing pilot version) has a pilot

that must be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appli-

ance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle to the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neigh-

bor’s phone. Follow the gas supplier’s instruc-
tions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it, call
a qualified service technician. Force or attempt-
ed repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system and any gas con-
trol which has been under water.

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE
INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR
LOSS OF LIFE.

1.

To access controls, open the lower grille.

2.

Turn the gas control valve knob to the OFF position.  To do this, you
must turn the knob clockwise  

 to the PILOT position, and then

press in and continue turning clockwise  

  to the OFF position.

NOTE:  

Knob cannot be turned from “PILOT” to “OFF” unless knob is

pushed in slightly. Do not force.

3.

WAIT AT LEAST FIVE (5)  MINUTES TO CLEAR OUT ANY GAS.  If
you have unsuccessfully tried to light the fireplace, wait longer, espe-
cially if you are using LP gas.  Then smell for gas, including near the
floor. If you then smell gas, 

STOP!

  Follow "B" in the safety informa-

tion on  previous page. If you don't smell gas, go to the next step.

4.

The pilot should not require accessing for lighting
purposes. The pilot is located inside the combustion
chamber. If it is necessary to access the pilot, re-
move the trim door and glass door.

              THERMOCOUPLE PILOT THERMOPILE

5.

To put the control in the PILOT position, turn the control knob counter-
clockwise  

  to the  PILOT position.

6.

To light the pilot press the control knob and then press the red or black
piezo button once every second.  The piezo makes a clicking sound.  It
may be necessary to repeat this step. If the pilot does not light after
10 seconds, go back to step 2.  The control knob should be held down
for a MINUTE after pilot ignition.

• If the control knob does not pop out when released, 

STOP! 

Shut off

the gas supply to the fireplace control valve, and 

IMMEDIATELY 

call

your service technician or gas supplier.

• If the pilot will not stay lit after two tries, turn the control knob to the

“OFF” position and call your service technician or gas supplier.

7.

After the pilot has been lit, the burner can be turned on by turning the
knob counter-clockwise 

 to the “ON” position.

8.

Set the ON/OFF switch to the “ON” position.

9.

Close the lower grille.

LIGHTING INSTRUCTIONS

STANDING PILOT CONTROLS

TO TURN OFF

GAS APPLIANCE

1.

Open the lower grille.

2.

Set ON/OFF switch to “OFF”.

3.

Turn the valve control knob clockwise 

 to the “Pilot” position,

then depress knob and continue turning to “OFF” position.

4.

Close the lower grille.

When you light your fireplace, you may notice:

This gas appliance produces heat which does have an associ-
ated odor or smell. If you feel this odor is excessive it may
require the initial 3-4 hour continuous burn on high followed by
a second burn up to 12 hours to fully drive off any odor from
paint and lubricants used in the manufacturing process.

You’ve reviewed all safety warnings, you’ve checked the
appliance for gas leaks, you know the vent system is

unobstructed, and you’ve checked for faulty components.
Now you’re ready to light the appliance.

!

After the Installation

LEAVE THIS INSTALLATION MANUAL WITH THE
APPLIANCE FOR FUTURE REFERENCE.

Noise caused by metal expanding and contracting as it heats
up and cools down, similar to the sound produced by a furnace
or heating duct. This noise does not affect the operation or
longevity of your fireplace.

During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the fireplace’s initial burning.

 Additionally, for the first few minutes after each lighting, vapor
may condense and fog the glass and flames may be blue.
After a few minutes this moisture will disappear and within
15-30 minutes the flames should become yellow.

Содержание QV32B-A

Страница 1: ...is appliance is not convertible for use with other gases unless a certified kit is used Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer pleasevisit www quadrafire com Printed in U S A Copyright 2006 WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUS ING PROPERTY DAMAGE ...

Страница 2: ...replace front READ and UNDERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL a qualified ser...

Страница 3: ... Step 2 Framing the Fireplace 15 Step 3 Installing the Vent System 18 A Vent System Approvals 18 B Installing Vent Components 28 C Vent Termination 31 Step 4 Positioning Leveling and Securing the Fireplace 34 Step 5 The Gas Control Systems 34 Step 6 The Gas Supply Line 35 Step 7 Gas Pressure Requirements 35 Step 8 Wiring the Fireplace 36 Step 9 Finishing 37 Step 10 Installing Trim Logs and Ember M...

Страница 4: ...6B A 2014 900 Rev F 9 06 Part number list on following page 4 3 5 2 7 1 6 NG LP Exploded Parts Diagram Service Parts QV32B A Beginning Manufacturing Date 6 03 Ending Manufacturing Date ______ 8 Log Set Assembly 12 11 10 9 13 Î ...

Страница 5: ...0 721 Exhaust Restrictor 530 299 Glass Latch Assembly 386 122A Y Regulator NG Pre 10 06 Post 10 06 060 518 230 1570 Y Y Regulator LP Pre 10 06 Post 10 06 060 519 230 1520 Y Y ACCESSORIES Fan Kit GFK 160A Wall Switch Kit Off white WSK 21 HTI Wall Switch Kit White WSK 21 W HTI Conversion Kit NG Pre 10 06 Post 10 06 NGK 2014 NGKS 2014 Y Conversion Kit LP Pre 10 06 Post 10 06 LPK 2014 LPKS 2014 Y Door...

Страница 6: ...a fire QV32B A QV36B A 2014 900 Rev F 9 06 9 11 12 13 1 2 3 4 5 7 6 8 Log Set Assembly 10 NG LP Exploded Parts Diagram Service Parts QV36B A Beginning Manufacturing Date 6 03 Ending Manufacturing Date ______ Î ...

Страница 7: ...46 505 2103 116 Y Pilot Orifice LP Pre 10 06 Post 10 06 446 517 2103 117 Y Thermocouple Pre 10 06 Post 10 06 446 511 2103 511 Y Thermopile Pre 10 06 Post 10 06 060 512 2103 512 Y Lava Rock 060 721 Mineral Wool 050 721 Exhaust Restrictor 530 299 Glass Latch Assembly 386 122A Y Regulator NG Pre 10 06 Post 10 06 060 518 230 1570 Y Y Regulator LP Pre 10 06 Post 10 06 060 519 230 1520 Y Y ACCESSORIES F...

Страница 8: ...r Neck Gasket 2046 407 6 Pilot Assembly NG PRE 10 06 POST 10 06 530 510A 2103 010 Y 6 Pilot Assembly LP PRE 10 06 POST 10 06 530 511A 2103 011 Y 7 Wire Assembly 049 552a 8 Valve Bracket PRE 10 06 POST 10 06 2025 101 2025 101 2044 155 9 Flex Ball Valve Assembly 302 320A Y 10 Piezo Ignitor 291 513 Y 11 Pilot Control Knob PRE 10 06 POST 10 06 291 530 571 531 12 Flame Control Knob PRE 10 06 POST 10 06...

Страница 9: ...m or bed sitting room in the U S A and Canada Appliance Certification The Village Collection fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories Certification MODELS QV32B A QV36B A LABORATORY Underwriters Laboratories TYPE Vented Gas Fireplace Heater STANDARD ANSI Z21 88 CSA2 33 UL307B High Altitude Installation...

Страница 10: ...ead in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installa tion unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5 08 2 a 1...

Страница 11: ...safety and benefit Failure to follow these instructions will void the owner s warranty and may present a fire hazard The Quadra Fire Warranty will be voided by and Hearth Home Technologies disclaims any responsibility for the following actions Installation of any damaged fireplace or vent system component Modification of the fireplace or direct vent system Installation other than as instructed by ...

Страница 12: ... 15 5 16 389mm 16 3 8 414mm 8 3 4 223mm Ø 6 5 8 168mm 15 7 8 402mm 37 3 4 960mm ELECTRICAL ACCESS 3 9 16 90mm 6 7 8 174mm 40 15 16 1040mm 36 1 8 917mm 35 5 8 905mm 25 635mm 40 1016mm GAS LINE ACCESS 2 1 8 55mm 5 1 16 129mm Ø 8 203mm TOP STANDOFFS GAS CONTROLS ELECTRICAL ACCESS GAS ACCESS RATING PLATE LABELS ...

Страница 13: ...LS ELECTRICAL ACCESS GAS ACCESS RATING PLATE LABELS Ø6 5 8 168mm 25 11 16 653mm 12 7 8 326mm 1 2 13mm 16 3 8 414mm 8 13 16 223mm 15 7 8 402mm 3 1 3 90mm 32 9 16 828mm Ø8 203mm 21 7 16 545mm 6 7 8 174mm ELECTRICAL ACCESS 32 1 8 815mm 31 1 8 790mm 36 913mm 2 1 8 55mm 35 7 16 901mm GAS LINE ACCESS 5 1 16 129mm ...

Страница 14: ...ments Constructing the Fireplace Chase A chase is a vertical box like structure built to enclose the gas fireplace and or its vent system Vertical vents that run on the outside of a building may be but are not required to be installed inside a chase CAUTION TREATMENT OF FIRESTOP SPACERS AND CONSTRUCTION OF THE CHASE MAY VARY WITH THE TYPE OF BUILDING THESE INSTRUCTIONS ARE NOT SUBSTITUTES FOR THE ...

Страница 15: ...4 36 1 2 24 3 8 A B C Step 2 Framing the Fireplace Fireplace framing can be built before or after the fireplace is set in place Framing should be positioned to accommo date wall coverings and fireplace facing material The dia gram below shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING The center of the frami...

Страница 16: ...CHES 34 93mm AT EACH JOINT Figure 6 DVP Series Direct Vent Component Specifications 5 inch inner pipe 8 inch outer pipe DVP90ST 12 9 16 11 1 4 7 1 4 1 1 4 TYP 1 2 TYP 8 9 16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN DVP12A 12 3 16 MAX DVP24 9 7 8 45 0O 10 1 4 DVP45 14 1 4 ...

Страница 17: ...t Specifications 4 inch inner pipe 6 5 8 inch outer pipe 120 3048mm 24 610mm 36 914mm 60 1524mm 9 1 4 6 5 8 6 1 2 6 3 8 6 1 2 9 5 8 9 5 8 6 5 8 6 3 8 8 3 4 SL 09D 12 17 SL 12 17D SL12 17D SL 24D SL 36D SL 48D 47 3 4 35 3 4 23 3 4 SL 45D SL 90D SL 17 24D SL17 24D 17 24 SL 06D SL 12D 5 3 4 6 5 8 6 1 2 11 3 4 SL FLEX 2 SL FLEX 10 SL FLEX 5 SL FLEX 3 ...

Страница 18: ...omponents are labeled for identifi cation NO OTHER VENTING SYSTEMS OR COMPO NENTS MAY BE USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this Installers Guide Figure 8 shows vent system components and terminations The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tio...

Страница 19: ...two 900 elbows in a corner installa tion will affect space requirements see Fig 4 Figure 9 Flex Vent The flex vent must be supported with the spacing between support intervals not exceeding 4 feet with no more than inch sag between supports A support is required at each change in venting direction and in any location where it is necessary to maintain the necessary clearance to combustibles Asimple...

Страница 20: ...ion in total H when using flex vent except when using the simple up and out installa tion see Figure 9 V MIN 90o Elbow on Top 1 FT 305mm 2 FT 610mm 3 FT 914mm 4 FT 1 22m 5 FT 1 52m VENTING WITH ONE 1 90o ELBOW NATURAL GAS H MAX 16 FT 4 8m V H MAX 40 FT 12 2m H MAX 2 FT 610mm 3 FT 914mm 4 FT 1 22m 6 FT 1 86m 8 FT 2 48m 16 FT 4 8m VENTING WITH ONE 1 90o ELBOW PROPANE V MIN H MAX 90o Elbow on Top NOT...

Страница 21: ... MAX 1 86 m 12 MAX 3 6m 4 MIN 1 22 m 8 MAX 2 48 m 16 MAX 4 8m V H H1 40 MAX 12 4 m H 8 MAX 2 48 m H H1 16 MAX 4 8m Figure 14 Venting with Two 90 Elbows V FT H H1 FT 1 MIN 305 mm 2 MAX 610 mm 2 MIN 610 mm 4 MAX 1 22 m 3 MIN 914 mm 6 MAX 1 86 m 4 MIN 1 22 m 8 MAX 2 48 m H H1 8 MAX 2 48 m V H H1 40 12 2m MAX Use DVP Series components only V H H1 H1 V H ...

Страница 22: ...NG WITH TWO 2 90o ELBOWS NATURAL GAS H H1 MAX 16 FT 4 8m V H H1 MAX 40 FT 12 2m H H1 MAX 2 FT 610mm 3 FT 914mm 4 FT 1 22m 6 FT 1 86m 8 FT 2 48m 16 FT 4 8m VENTING WITH TWO 2 90o ELBOWS PROPANE H H1 MAX 16 FT 4 8m V H H1 MAX 40 FT 12 2m V MIN H H1 MAX 90o Elbow on Top NOTALLOWED 1 FT 305mm 2 FT 610mm 2 FT 610mm 4 FT 1 22m 3 FT 914mm 6 FT 1 86m 4 FT 1 22m 8 FT 2 48m 5 FT 1 52m 16 FT 4 8m V MIN 90o E...

Страница 23: ... VENTING WITH TWO 2 90o ELBOWS NATURAL GAS H MAX 16 FT 4 8m V V1 H MAX 40 FT 12 2m H MAX 2 FT 610mm 3 FT 914mm 4 FT 1 22m 6 FT 1 86m 8 FT 2 48m 16 FT 4 8m VENTING WITH TWO 2 90o ELBOWS PROPANE H MAX 16 FT 4 8m V V1 H MAX 40 FT 12 2m V MIN H MAX 90o Elbow on Top NOTALLOWED 1 FT 305mm 2 FT 610mm 2 FT 610mm 4 FT 1 22m 3 FT 914mm 6 FT 1 86m 4 FT 1 22m 8 FT 2 48m 5 FT 1 52m 16 FT 4 8m V MIN 90o Elbow o...

Страница 24: ... 12 MAX 3 72m 4 MIN 1 22m 8 MAX 2 48m 16 MAX 4 8m V1 V H H1 40 MAX 12 4m H 8 MAX 2 48m H H1 16 MAX 4 8m V H H H1 1 MIN 305 mm 2 MAX 610 mm 4 MAX 1 22m 2 MIN 610 mm 4 MAX 1 22 m 8 MAX 2 48m 3 MIN 914 mm 6 MAX 1 86 m 12 MAX 3 72m 4 MIN 1 22 m 8 MAX 2 48 m 16 MAX 4 8m V H H1 H2 40 MAX 12 4 m H 8 MAX 2 48m H H1 H2 16 MAX 4 8m V H H H1 H2 Use DVP Series components only H H1 H2 V H V H1 V1 ...

Страница 25: ...E 3 90o ELBOWS PROPANE V H V1 H1 MAX 40 FT 12 2m V H V1 H1 MAX 40 FT 12 2m V MIN H MAX H H1 MAX 90o Elbow on Top 2 FT 610mm 4 FT 1 22m 1 FT 305mm 3 FT 914mm 6 FT 1 86m 2 FT 610mm 4 FT 1 22m 8 FT 2 48m 3 FT 914mm 6 FT 1 86m 12 FT 3 72m 4 FT 1 22m 8 FT 2 48m 16 FT 4 8m 5 FT 1 52m 16 FT 4 8m 16 FT 4 8m V MIN H MAX H H1 MAX 90o Elbow on Top NOTALLOWED NOTALLOWED 1 FT 305mm 2 FT 610mm 4 FT 1 22m 2 FT 6...

Страница 26: ...4 8m V V1 H H1 MAX 40 FT 12 2m Model QV36B A H H1 MAX 2 FT 610mm 3 FT 914mm 4 FT 1 22m 6 FT 1 86m 8 FT 2 48m 16 FT 4 8m VENTING WITH THREE 3 90o ELBOWS PROPANE H H1 MAX 16 FT 4 8m V V1 H H1 MAX 40 FT 12 2m V MIN H H1 MAX 90o Elbow on Top NOTALLOWED 1 FT 305mm 2 FT 610mm 2 FT 610mm 4 FT 1 22m 3 FT 914mm 6 FT 1 86m 4 FT 1 22m 8 FT 2 48m 5 FT 1 52m 16 FT 4 8m Model QV32B A V MIN H H1 MAX 90o Elbow on...

Страница 27: ...90 ELBOWS NATURAL ANDPROPANEGAS V MIN H MAX 2 609mm 5 1 52m V1 MIN H1 MAX V2 MIN 5 1 52m 5 1 52m 4 5 1 37m V V1 V2 H H1 MAX 40 12 2m V H V2 V1 H1 NOTE There MUST be a 25 reduction in total H when using flex vent except when using the simple up and out installa tion see Figure 9 Use SL D Series components only ...

Страница 28: ...vent component is secure ly fitted and locked into the preceding component in the vent system 90 elbows may be installed and rotated to any point around the preceding component s vertical axis If an el bow does not end up in a locked position with the pre ceding component attach with a minimum of two 2 sheet metal screws 3 Install Support Brackets Refer to Cinch Pipe and Termination Cap installati...

Страница 29: ...ontalpipesupport To install support brackets for horizontal runs Place the pipe supports around the vent pipe Nail the pipe supports to the framing members WALL BRACKET WALL STUD 1 INCH MIN 25 4mm 8 FT 2 4m FLUE OUTLET If the installation is for a termination cap attached directly to the fireplace skip to the sections Install Firestops and Vent Termination SL D and SL Flex Series Venting Only 1 At...

Страница 30: ...LE 10 254mm 10 254mm Position the firestops on both sides of the hole previ ously cut and secure the firestops with nails or screws The heat shields of the firestops MUST BE placed to wards the top of the hole Continue the vent run through the firestops Figure 24 Hole and Vent Pipe Figure 25 Heat Shield Interior Exterior Firestops TRIM HEAT SHIELD IF TOO LONG ADD TO SHIELD IF TOO SHORT EXTERIOR FI...

Страница 31: ...n structions Figure 29 Trapezoid Termination Cap 7 1 4 184mm WARNING THE TERMINATION CAPMUST BE POSITIONED SO THAT THEARROW IS POINT ING UP WARNING VENTING TERMINALS SHALL NOT BE RECESSED INTO A WALL OR SID ING VENT TERMINATION CLEARANCES MUST BE FOLLOWED TO AVOID FIRE DANGER SEE VENT TERMINATION MINIMUM CLEARANCES DI AGRAM ON FOLLOWING PAGE For All Venting Figure 27 Ceiling Firestop Ceiling Side ...

Страница 32: ...ce spaces open only on one side and with an overhang are permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 fo...

Страница 33: ...IAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMI NATION CAP IS AT LEAST TWO 2 FEET 20 INCH ES FOR DVP PIPE FROM AVERTICAL WALLAND 2 FEET BELOW AHORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems in stalled on the outside of the building Roof Pitch H min ft flat to 6 12 1 0 6 12 to 7 12 1 25 over 7 12 to 8 12 1 5 over 8 12 to 9 12 2 0 over 9 12 to 10 12 2 5 over 10 12 to 11 12 3 25 o...

Страница 34: ...igure 32 Proper Positioning Leveling and Securing of a Fireplace Figure 33 Gas Control System STANDINGPILOT Step 5 The Gas Control System WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The type of gas control system used with this model is Standing Pilot Ignition Standing Pilot Ignition System This system includes millivolt control valve standing pilot thermopile thermocouple flame sensor and pi...

Страница 35: ...the outer wrap does not exceed 2 in diameter and it does not penetrate the actual firebox Open the fireplace lower grille insert the gas supply line throughthegaslinehole andconnectittotheshut offvalve When attaching the pipe support the control so that the lines are not bent or torn After the gas line installation is complete use a soap solution to carefully check all gas connections for leaks WA...

Страница 36: ...ional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the fireplace is permanently installed Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC TION WHE...

Страница 37: ...P SEAL JOINT SIDE SEAL JOINT 0 0 FINISH MATERIAL MAY BE COMBUSTIBLE TOP AND SIDES OF UNIT Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace but MUST NEVER overlap onto the front face The joints between the finished wall and the fireplace top and sides can only be sealed with a 300 F 149 C minimum sealant WARNING...

Страница 38: ...ace Review safety warnings and cautions Read the Safety and Warning Information section at the beginning of this Installers Guide Double check for gas leaks Before lighting the fireplace double check the unit for possible gas leaks Double check vent terminations and front grilles for obstructions Before lighting the fireplace double check the unit for possible obstructions that could be blocking t...

Страница 39: ...he PILOT position turn the control knob counter clockwise to the PILOT position 6 To light the pilot press the control knob and then press the red or black piezo button once every second The piezo makes a clicking sound It may be necessary to repeat this step If the pilot does not light after 10 seconds go back to step 2 The control knob should be held down for a MINUTE after pilot ignition If the...

Страница 40: ...ontrol compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Make sure the flames are steady not lifting or floating See Figure 46 The thermopile thermocouple tips should be covered with flame See Figure 33 Figure 46 Burner Fl...

Страница 41: ...uple copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocouple is producing more than 15 millivolts replace faulty valve 3 The pilot is burning there is no gas burner the valve knob is in the ON position and the ON OFF switch is in the ON position a ON OFF switch or wires defective Check the ON O...

Страница 42: ...ing the unit The maximum downwards lope is 1 4 inch d Glass too loose and air tight packet leaks in corners after usage Tighten the corner e Bad thermopile or thermocouple Replace if necessary f Improper vent cap installation Check for proper installation and freedom from debris or blockage 6 Glass soots a Flame impingement Adjust the log set so that the flame does not excessively impinge on it b ...

Страница 43: ... Home Technologies discontinues the model and two 2 years for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation of upgraded component parts do not quality for a service call fee and will not be covered This limited Lifetime Warranty does not...