Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTAL FIREPLACE OPERATION.
For Standing Pilot Ignition Wiring
Appliance Requirements
•
This appliance
DOES NOT
require 110-120 VAC to operate.
WARNING: DO NOT CONNECT 110-120 VAC TO
THE GAS CONTROL VALVE OR WALL SWITCH
OR THE APPLIANCE WILL MALFUNCTION
AND THE VALVE WILL BE DESTROYED
.
!
Figure 35. Standing Pilot Ignition Wiring Diagram
Figure 36. Fan Wiring Diagram
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the fireplace is permanently installed.
Wall Switch
Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
W
H
T
W
H
T
B
L
K
B
L
K
GRN WIRE
INSIDE BOX
COPPER
GROUND ATTACHED
TO GRN SCREW WITH
GRN WIRE
14/2WG
COVER PLATE
OUTSIDE FIREBOX
ROMEX
CONNECTOR
BLOWER
SENSOR
SWITCH
FAN
RECEPTACLE
SPEED
CONTROL
ON
OFF
ON/OFF
SWITCH
REMOTE SWITCH
PIGTAIL
OPTIONAL WALL SWITCH,
THERMOSTAT OR REMOTE
PILOT
STANDING
WHT
RED
VALVE