MHC36 AND MHR36 INSTALLATION INSTRUCTIONS

Note: 

Save and pass this instruction manual to subsequent home owners. The informa-

tion provided is intended to notify and warn them about making unsafe future modifica-
tions such as the addition of shelves or the use of unauthorized parts and repairs.

WARNING!

DO NOT operate this fireplace with the flue
damper in the closed position. Combustion
products must vent up the chimney system to
prevent carbon monoxide poisoning, and to
prevent hot combustion gases from contacting
and overheating combustible surfaces. Failure
to operate this fireplace with the damper in the
open position may result in asphyxiation or a
structure fire.

CAUTION:

Fireplace operation does require air. Do not take
air from other fuel burning appliances which can
result in improper venting (smoking) or air di-
lution. Always provide adequate makeup air.

G. OPERATING INSTRUCTIONS

1. General Information

This fireplace is intended to operate as a supplemental
heat source for a single room. It is not designed to
function as a primary heat source for a structure.

Fireplaces, as well as other woodburning appliances,
have been used safely for many years. It has been our
experience that most problems are caused by improper
installation and operation of the fireplace. Make certain
that installation and operation of the fireplace system
is in accordance with these instructions.

It is extremely important that the fire be supervised
whenever the fireplace is in use. It is also
recommended that an annual inspection be performed
on the fireplace system to determine if the flue system
needs to be cleaned, or as in the case of any appliance,
if minor repairs are required to maintain the system in
top operating condition.

This factory built fireplace is intended for use with either
solid fuel (firewood) or a decorative gas appliance that
has been tested and listed to the 

Standard for

Decorative Gas Appliances for Installation in
Vented Fireplaces, ANSI Z21.60

. When operating

your fireplace, the flue damper must be in the open
position.

This fireplace was not tested and listed for use with an
unvented gas log heater. Do not install an unvented
gas log heater in this fireplace and operate it with the
flue damper in the closed position unless the unvented
gas log heater has been specifically tested and listed
for use in this fireplace by Underwriters Laboratories
Inc.

Use of an unvented gas log heater in this factory
built fireplace may create a fire hazard that can
result in a structure fire.

2. Outside Air

A source of air (oxygen) is required in order for
combustion to take place. Whatever air is consumed
by the fire must be replaced through cracks around
windows, under doors, etc. Most newly constructed
houses or existing homes fitted with tightly sealed doors
and windows are relatively air tight. In this case, an
outside air source must be made available to feed
combustion air from outside the home.

A damper control handle allows the individual control
of the outside air inlet if your fireplace is equipped with
this option. Use of outside air for combustion is highly
recommended to conserve heated air within the
structure and to provide make up air to keep the
fireplace venting properly.

This fireplace will operate correctly only if adequate
ventilation is provided to allow proper draft to the
fireplace system. Hearth & Home Technologies
assumes no responsibility for the improper
performance of the fireplace system caused by
inadequate draft due to environmental conditions, down
drafts, tight sealing construction of the structure, or
mechanical exhausting devices which create a
negative air pressure within the structure where the
fireplace is located.

3. Flue Damper

The flue damper must be in a full open position.  Before
lighting the fire, verify this by looking up from the inside
of the fireplace. Always operate this fireplace with the
damper fully open.  Pull the handle down to open and
push the handle up to close.  Please note: down drafts,
obstructions, damaged or poor (wet) fuels can cause
smoke spillage.

Содержание MHC36

Страница 1: ...njury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier INSTALLATION OPERATING INSTRUCTIONS MHC36 MHR36...

Страница 2: ...tside air kit is highly recommended In the event the home is unusually tightly sealed the optional combustion air kit may not provide all the air required to support combustion Hearth Home Technologie...

Страница 3: ...e of the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the fir...

Страница 4: ...inimum and maximum clearances must be maintained at all times The illustrations and diagrams used throughout these installation instructions are not drawn to scale Figure 1 Typical Fireplace System B...

Страница 5: ...egral Grate Catalog Description MHR36 Radiant Fireplace with Integral Grate Hearth Protection Strips and Outside Air Kit MHC36 Circulating Fireplace with Integral Grate Hearth Protection Strips Fan Ki...

Страница 6: ...y Section 24 in long SL336 Chimney Section 36 in long SL348 Chimney Section 48 in long SL315 Chimney Offset Return 15 deg SL330 Chimney Offset Return 30 deg JB877 Chimney Joint Band CB876 Chimney Brac...

Страница 7: ...S8 Attic Insulation Shield RF371 Roof Flashing Flat to 6 12 Pitch Firestop Spacer A Actual Length B Effective length length of chimney part after it has been snapped to another RF370 Roof Flashing 6 1...

Страница 8: ...hould be given to these factors before deciding on a location CLEARANCES A minimum 1 in air clearance must be maintained at the back and sides of the fire place assembly except at the nailing flange w...

Страница 9: ...e the possibility of fireplace smoking or air flow reversal WARNING To prevent contact with sagging or loose insulation the fireplace must not be installed against vapor barriers or exposed insulation...

Страница 10: ...opening of 39 5 8 in wide x 33 5 8 in tall The finished cavity depth must be no less than 19 3 4 in Figure 5 shows a typical framing using 2 x 4 lumber of the fireplace assuming combustible materials...

Страница 11: ...your fireplace location the chimney construction and necessary clearances must be considered The fireplace system and chimney components have been tested to provide flexibility in construction The fol...

Страница 12: ...e the offset and return 4 Read across the chart and find the number of chimney sections required and the model number of those particular chimney parts 5 Whenever the chimney penetrates a floor ceilin...

Страница 13: ...Rule This rule states If the horizontal distance from the side of the chimney to the peak of the roof is 10 ft or less the top of the chimney must be at least 2 ftabove the peak of the roof but never...

Страница 14: ...nstructions for framing on pages 9 11 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Place the Protective Metal Hearth...

Страница 15: ...stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney section below it See Figure 10 5 I...

Страница 16: ...eld An insulation shield should be installed when there is a possibility of insulation coming into contact with the factory built chimney system The insulation shield is installed by positioning it ov...

Страница 17: ...the extension to the thimble drill 1 8 in holes through the outer shield of the thimble using the predrilled holes in the extension as guides Attach the extension to the thimble using the screws provi...

Страница 18: ...s installed on the left hand side of the fireplace Remove the cover plate from the side of the fireplace assembly where the air kit is to be installed See Figure 16 for handle location operation WARNI...

Страница 19: ...e fire 13 Gas Log Lighter Provisions Knockouts are provided on both sides of the fireplace to allow for connection of a certified gas log lighter or a decorative gas appliance with a maximum input of...

Страница 20: ...ust be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are show...

Страница 21: ...those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn General Electr...

Страница 22: ...s Appliances for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unven...

Страница 23: ...ave a greater density than soft woods A piece of hardwood will contain about 60 more BTU s than an equal size piece of soft wood Firewood is commonly sold by the cord 128 cu ft A cord of seasoned oak...

Страница 24: ...k the wood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying pro...

Страница 25: ...imney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of s...

Страница 26: ...rred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yours...

Страница 27: ...22 Gas Knockout Location 6 Gas Log Lighter Provisions 19 General Information 22 Glass Doors 5 21 23 Grate 5 23 H Hearth Extension 20 Positioning 21 I Installation Along a Wall 9 In a Corner 9 Insulat...

Страница 28: ...haust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any oth...

Отзывы: