Turn unit off using on/off switch in battery compartment. 

 

 Press and hold pairing button and switch unit ON at the same 
time. 

 

Red LED light comes on for approx. 3 sec. Once red light goes out 
release pairing button and press it once again quickly. 

 

EchoAlert® Sound Sensor is un-paired from master unit. 

 

 

Installation:

 

 

 

Place the product within 10cm of the chosen device for example 
alarm, siren, intercom etc. When the product detects the sound, 
the red indicator will flash once and will trigger EchoAlert® 
Vibrating Pager (master unit). 

 

Low battery indicator:

 

 

 

The EchoAlert® Vibrating Pager indicator 

4

 flashes white once 

every 5 sec. to indicate EchoAlert® Sound Sensor batteries are low 
and need changing. 
 

 

Switching unit off:

 

    

 

Turn switch to OFF position (Switch located in the battery 
compartment) 

Содержание 474-1006-01

Страница 1: ...EchoAlert Wireless Home Alert System www hear4you com Product code 474 1006 01...

Страница 2: ...ery cold To clean the EchoAlert and its accessories use only a soft cloth and an inorganic cleaner Please refer all servicing to qualified personnel only Do not attempt to open the units this will inv...

Страница 3: ...ided if bell push used in wet damp or dusty environment Fully functioning EchoAlert Vibrating Pager paired correctly must be kept within prescribed range at all the times to ensure operation of the wh...

Страница 4: ...660 1016 01 3 EchoAlert Sound sensor product no 660 1019 01 4 EchoAlert Bellpush product no 660 1018 01 5 Bell push cover product no 660 1021 01 6 AA Alkaline battery 4pcs product no 105 7 Battery for...

Страница 5: ...1 2 3 4 5 6 7 8 9 Manual 10...

Страница 6: ...unit is a portable vibrating flashing alarm which can be connected wirelessly to a number of accessories including EchoAlert Bell Push EchoAlert Smoke Alarm and EchoAlert Sound Sensor and alert the us...

Страница 7: ...Alarm indicator Red Light 3 Pairing indicator LED additional accessory Orange Light 4 Sound Sensor indicator White Light 5 Vibrating Pager battery indicator Green Yellow Light 6 Strobe Flash LED 7 TE...

Страница 8: ...eed changing Pairing Please note this set should already be paired and ready to use If for any reason set requires re pairing please follow instructions below Press the pager TEST RESET button 7 three...

Страница 9: ...moke Alarm Connection Test Please be aware that this test is to confirm if EchoAlert Smoke Alarm is successfully paired with EchoAlert Vibrating Pager master unit For regular smoke alarm testing pleas...

Страница 10: ...Model EchoAlert Vibrating Pager Power DC3V AA Alkaline battery x2 Standby current 110uA 3V Alarm current 500mA 3V RF frequency 868MHz 50KHz RF transmitting power 13dBm Transmission range up to 100mete...

Страница 11: ...sounds including alarms intercoms landline phones etc It is paired with EchoAlert Vibrating Pager master unit to notify user if sound is detected Please note we recommend testing EchoAlert Sound Sens...

Страница 12: ...or 3 ON OFF switch 4 Sensitivity switch Low Mid High Battery installation Open battery compartment and install 2x AA Alkaline batteries according to polarity label Please note batteries must be fully...

Страница 13: ...lert Vibrating Pager master device Activate pairing mode in EchoAlert Vibrating Pager as instructed on previous pages Press EchoAlert Sound Sensor pairing button 1 three times within 3 seconds and red...

Страница 14: ...er unit Installation Place the product within 10cm of the chosen device for example alarm siren intercom etc When the product detects the sound the red indicator will flash once and will trigger EchoA...

Страница 15: ...ttery compartment Technical specification Model EchoAlert Sound Sensor Power DC3V AA Alkaline battery x2 Standby current 80uA Max RF current 25mA RF frequency 868MHz 50KHz Standards ROHS CE UKCA Low b...

Страница 16: ...ed with EchoAlert Vibrating Pager master unit to alert user that someone is at the door It can be placed on the door frame using double sided tape or screws If bell push is installed in a humid enviro...

Страница 17: ...y compartment Pairing Please note this unit should already be paired and ready to use If for any reason set requires re pairing please follow instruction below Pairing with EchoAlert Vibrating Pager m...

Страница 18: ...d light goes out release button and press it once again quickly EchoAlert Bell Push is now un paired Low battery indicator The EchoAlert Vibrating Pager indicator 1 flashes blue once every 5 sec to in...

Страница 19: ...4 EchoAlert Smoke Alarm Product description EchoAlert Smoke Alarm is an optical wireless smoke alarm device connected to EchoAlert Vibrating Pager master device to alert user if smoke detected...

Страница 20: ...ape rooms In the middle of the ceiling of a room At least 50 cm away from the wall and other objects Maximum installation height of 6 meters If ceiling installation is not possible the smoke alarm can...

Страница 21: ...oke alarm In an environment with a high risk of draught e g close to air conditioning fans and ventilation outlets The movement of air can impair the penetration of fire smoke into the smoke alarm Are...

Страница 22: ...e by quickly pressing the test button three times 2 The orange LED will light up followed by red and white LEDs This indicates that EchoAlert Vibrating Pager is in pairing mode 3 Enter pairing mode on...

Страница 23: ...master unit Please follow instruction below Unpairing process 1 Disconnect the smoke alarm you want to unpair from the mounting plate or by turning the activation switch with a screwdriver 2 Press and...

Страница 24: ...ape to install it on the ceiling Test the correct operation of your smoke alarm by pressing the test on If sound is not generated the smoke alarm does not operate correctly and should be replaced Low...

Страница 25: ...Test all smoke alarms weekly for correct operation using test function If EchoAlert Smoke Alarm operates correctly it will generate a loud beep Due to the loudness of the alarm make sure that you alw...

Страница 26: ...moke alarm may not alert every household member The alarm horn is loud and pager s flash and vibration powerful However there may be some circumstances where a persons may not hear see or feel the ala...

Страница 27: ...ives or property from fire Smoke alarms are not an insurance substitute EchoAlert system including smoke alarm must be tested weekly If any faults found or it does not operate properly you must replac...

Страница 28: ...s exist for your nearest facility see www recycle more co uk or Hearing Products International Limited for full details at www hear4you com Hearing Products International Limited Echo House 26 27 Haig...

Отзывы: