Page 23
HCSTEAM−16/−35 SERIES
Table 5. Replacement parts
Item
Part No.
Description
1
2
3
8
5b
5a
10
11
6
9
7
12
13
1
STEAM CYLINDER
Y3481
CYLINDER STD. CONDUCTIVITY 110−120/1 5.5 LBS/HR MODELS
Y3482
CYLINDER STD. CONDUCTIVITY 220−240/1 12 LBS/HR MODELS
Y3484
CYLINDER LOW CONDUCTIVITY 220−240/1 12 LBS/HR MODELS
2
Y3773
CONTROL MODULE 5.4 kg/h 220−240 VAC
Y3774
CONTROL MODULE 2.5 kg/h 110−120 VAC
3
ON/OFF SWITCH (special order)
5a,b
Y3775
FILL (
5a
) & DRAIN TEMPERING VALVE (
5b
) 110−120 VAC
Y3776
FILL (
5a
) & DRAIN TEMPERING VALVE (
5b
) 220−240 VAC
6
Y3777
DRAIN PUMP 110−120 VAC
Y3778
DRAIN PUMP 220−240 VAC
7
Y3779
90 DEGREE DRAIN ELBOW
8
FILL CUP + PLUG
9
FILL CUP HOSE
DRAIN HOSE
10
Y3780
COVER HOLDING SCREWS (4 USED)
11
DRAIN PAN
12
DRAIN TANK + PLUG
13
Y3801
STEAM CYLINDER HOSE ADAPTER
Other replacement parts and accessories:
S
Steam Hose (10’ Y3782)
S
Steam Condensate hose 10’ (Y3783)
S
Fill Hose (Y3784)
S
Air proving switch (Y3786)
S
HC Digital Automatic Humidistat (Y3760)
S
ComfortSense
®
7000 thermostat (Y2081)
S
icomfort Touch
®
thermostat (49W95)
S
Steam Nozzle (Y3781)
Table 6. Technical Specifications
Steam flows, VAC, kW
5.5 lbs/hr (2.5 kg/h): 110−120 VAC 1−phase 50−60 Hz, 1.86 kW
12 lbs/hr (5.4 kg/h): 220−240 VAC 1−phase 50−60 Hz, 4.05 kW
Notes
Steam pressure
3.81 in w.c. / 950 Pa
For duct only.
Dimensions (mm )
24" x 14" x 8" (600 x 341 x 204 mm)
(Height x Width x Depth)
Weight empty / packaged / installed with
water
18 / 22 / 26 lbs. (8 / 10 / 12 kg)
Electrode power cables
12 AWG
Power relays
2 x 30 Amp
On board.
Ground connection
Screw
Input water type
Potable water
No demineralized or softened water.
Conductivity range
125−1250
μ
S/cm
Special cylinder for low conductivity
<350 (for 220−240 volt model only).
Water fill connection
3/4" female water hose connection
Adapter to
¾
" FPS..
Water fill − instant flow
0.09 – 0.16 gpm (0.35 – 0.60 l/min)
Drain connection
1.25" O.D. (32 mm)
Adjustable from horizontal to
downward. May be from back or
bottom of unit.
Drain water temp
< 140
°
F (< 60
°
C)
Drain tempering device.
Drain flow
Max 7.1 gpm (max 26.8 l/min)
Ambient indoor operating and storage
temperatures and humidity (outdoor
installation not valid)
Operating temperature:
34
°
F to 104
°
F (1
°
C to 40
°
C)
Operating relative humidity: 10 to 60% RH
Storage temperature:
14
°
F to 158
°
F (−10
°
C to 70
°
C)
Storage relative humidity:
5 to 95% rH