![Healthrider 831.297820 S Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/healthrider/831-297820-s/831-297820-s_user-manual_2113618013.webp)
13
PROBLEM: The walking belt is off-center when walked on
SOLUTION:
a. If the walking belt has shifted to the left, first remove
the key and
UNPLUG THE POWER CORD
. Using
the allen wrench, turn the left rear roller adjustment
bolt clockwise, and the right bolt counterclockwise,
1/4 of a turn each. Be careful not to overtighten the
walking belt. Plug in the power cord, insert the key
and run the treadmill for a few minutes. Repeat until
the walking belt is centered.
b. If the walking belt has shifted to the right, first remove
the key and
UNPLUG THE POWER CORD
. Using
the allen wrench, turn the left rear roller adjustment
bolt counterclockwise, and the right bolt clockwise,
1/4 of a turn each. Be careful not to overtighten the
walking belt. Plug in the power cord, insert the key
and run the treadmill for a few minutes. Repeat until
the walking belt is centered.
PROBLEM: The walking belt slips when walked on
SOLUTION:
a. If the walking belt slips when walked on, first remove
the key and
UNPLUG THE POWER CORD
. Using
the allen wrench, turn both rear roller adjustment
bolts clockwise, 1/4 of a turn. When the walking belt
is correctly tightened, you should be able to lift each
side of the walking belt 3 to 4 inches off the walking
platform. Be careful to keep the walking belt centered.
Plug in the power cord, insert the key and carefully
walk on the treadmill for a few minutes. Repeat until
the walking belt is properly tightened.
PROBLEM: THE WALKING BELT NEEDS TO BE CLEANED
SOLUTION:
a. Use a color-fast upholstery cleaner to clean the walking belt. Test the cleaner on a small area be-
fore cleaning the entire belt.
b
a
a