6
.
CALIBRATION PROCEDURE
.
This scale has been calibrated at the factory and does not require re-calibration prior to use.
The calibration procedure may be performed using a known weight in either kilograms or pounds. Simply set the scale for the desired unit of
measure using the KG/LB key and start the calibration procedure. The following instructions assume the scale is set to measure lbs. The
calibration is performed using kg or lb, according to the unit of measure used upon entering into the calibration path. Note: The calibration
weight must be no less than 60 lb (28 kg) and no more than 300 lb (135 kg).
The calibration is performed using kg or lb, according to the unit of measure used upon entering into the calibration path.
OPERATOR ACTION
DISPLAY
While display module is turned on and “START’ is displayed on the LCD
(for 3 seconds); Press ZERO-KG/LB-KG/LB-ZERO
“CAL” will appear on the LCD
Press ENTER
Enter load weight “Load/300.0”
Press ENTER to calibrate with 300lb
Press BMI to change the weight and then the arrows to change the
flashing digit, BMI to move to the next digit, until you reach the
required weight (no less than 60lb and no more than 300lb)
“CLEAR”
Clear the platform and press ENTER
Zero Calibration
“-----------”
Wait without touching or shaking the scale until the zero calibration
process is finished
Weight calibration
“Put XXX.X”
Load the platform with the required weight and press ENTER
Weight calibration
“Put XXX.X”
Press ENTER
“DONE”/“CLEAR”/XXX
Remove weight from the platform
Rebooting, please wait
Wait until the scale resumes normal operation
“0.0”
.
EXPLODED VIEW OF SCALE
.