Health O Meter 522KG Скачать руководство пользователя страница 5

P/N UM522KL_522KG Rev20190412                                     

 

CERTIFICATIONS / CONNECTIVITY / DISPOSAL 

 

Certification Descriptions 

 

 
 

Scale Connectivity Information 

For reliable transmission of weight data, this scale is designed to connect to a computer, 
monitor, or other electronic data device via Health o meter

®

 Professional Connectivity Solutions. 

This connectivity helps minimize transcription errors when recording patient data. For further 
information regarding how to connect this scale to other electronic devices, please contact 
Health o meter

®

 Professional Scales Technical Support at 800-638-3722 or visit 

www.homscales.com/innovations/connectivity.

 

 

 

Scale Disposal 

 

 

 

This Health o meter

®

 Professional scale must be disposed of properly as electronic waste.  

Follow the national, regional or local regulations which apply to you for disposal of electronic 
waste or batteries.  Do not dispose of this device in the domestic waste stream.  

 

 

 

 

 

 

 

 

 

 
 
 

 

Pelstar, LLC has been officially certified as the manufacturer 
of Health o meter

®

 Professional medical devices. The Pelstar, 

LLC quality assurance system covers the development, 
production, sales and service of medical scales and 
measuring systems. 

 

 

This product is tested to and meets the requirements of: 

1. UL60601-1 First Edition: Safety for Medical Electrical 
Equipment 

2. CSA C22.2 No. 601-1 M90: Medical Electrical Equipment 

Содержание 522KG

Страница 1: ...G Digital Pediatric Tray Scale User Instructions PELSTAR LLC 9500 West 55th St McCook IL 60525 7110 USA www homscales com Health o meter Professional 522KL Health o meter Professional 522KG Pelstar LL...

Страница 2: ...cations 4 Certifications Connectivity Disposal 5 Assembly Instructions 6 Powering the Scale 9 Operating Instructions 10 Maintenance and Cleaning 12 Calibration 13 Troubleshooting 14 Warranty 15 Note T...

Страница 3: ...vely with the AC adapter provided by Health o meter Professional Use of an unspecified adapter will void the warranty and can pose a serious safety hazard For use with AC adapter model ADPT31 USA or C...

Страница 4: ...ents Adapter Model No UE15WCP1 090050SPA Part No UE160714HKKK1 P Health o meter Professional Model ADPT30 Not Included Input 100 240V 50 60Hz 500mA Output 9 0V 0 5A Or 6 AA Batteries included Environm...

Страница 5: ...638 3722 or visit www homscales com innovations connectivity Scale Disposal This Health o meter Professional scale must be disposed of properly as electronic waste Follow the national regional or loca...

Страница 6: ...as you unpack the parts for assembly To prevent scratching any components carefully remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid dam...

Страница 7: ...s side and place the column on its side perpendicular to the platform The front of the display head on the column should be facing forward and above the scale platform 4 Locate the load cell connector...

Страница 8: ...scale platform screw holes Using a Phillips head screwdriver tighten the screws to secure the column to the base of the platform 6 Locate the 2 M6 x 16mm screws included in the clear plastic bag Align...

Страница 9: ...em is not corrected contact Health o meter Professional Scales Customer Service at 1 800 815 6615 Note If Lo appears on the display it indicates that the battery power is low It does NOT indicate a pr...

Страница 10: ...weight measuring unit follow the instructions below Locking the Weight Measuring Unit 522KL Only The weight measuring unit can be locked to only measure in KG or LB Follow the procedures below to lock...

Страница 11: ...ASE button To release press the HOLD RELEASE button again 5 After the weight measurement has been taken and is recorded remove the baby from the weighing tray After weight is removed from the tray the...

Страница 12: ...Disconnect the scale from the AC adapter power source prior to cleaning the unit 1 Health o meter Professional recommends using one of the following solutions on a soft cloth or disposable wipe mild s...

Страница 13: ...C 5 will flash on the display followed by 0 or 1 C 5 then 0 or 1 Place 5 kg on the scale Four numbers will appear When calibration numbers stabilize press the ZERO TARE button C 10 will appear on the...

Страница 14: ...weight value Weighing is performed but the weighing process takes too long and the weight does not lock on the display The patient is not laying still Try to have the patient lay still The display sh...

Страница 15: ...d hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jur...

Отзывы: