10.5 Six Month Inspection
The TRUBLUE iQ Auto Belay requires an in-depth six (6) month inspection by the
Owner/operator. For the six month inspections the unit must be dismounted and
removed to a sturdy work table.
10.5.1 INSPECTION PROCEDURE
1. Dismount the Auto Belay (refer to Installation Instructions).
2. Clean Auto Belay using a clean cloth.
3. Carry out Steps 1 through 6 of the ‘Weekly Inspection’.
4. Remove the Nozzle – Refer to
“To remove the Nozzle assembly”
section below.
5. Inspect Nozzle Assembly for the following:
Excessive wear to slot, which could affect retraction of the webbing.
Splitting, cracking and deformation.
Correct fit in housing.
Nozzle Wear
Check Nozzle for excessive
wear around slot
10.5.2 WEBBING INSPECTION
1. With Nozzle assembly removed, pull out the complete webbing line,
including approx. 100 mm (4 in) of the short webbing loop.
Twist the webbing 90 degrees, then place a suitable pin through the
loop in the short webbing loop, above the joining link to prevent it
retracting back into the unit.
2. Inspect the webbing line by passing the webbing slowly through your hands
under a good light. Inspect the webbing for:
Damage to stitching (cuts or abrasion).
Cuts to webbing, especially to edges.
Abrasion across the surface of the webbing, wear and fraying, especially
to the edges.