LIMITED  WARRANTY

HD FIRE PROTECT PVT. LTD. hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person 
to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two (2) years from the date of 
shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturer’s warranty. 
No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained. 
HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyer’s representatives.
HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is 
found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly 
or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufactured 
by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any 
damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire’s product liability exceed an amount equal to the sale price.
The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited 
to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled.

NOTICE :

The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the 
provision of government codes or ordinances wherever applicable.
The information provided by us is to the best of our knowledge and belief, and consist of general guidelines only. Site handling and installation control is not in our scope. 
Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or 
damages due to our product.
Product development is a continuous programme of HD FIRE PROTECT PVT. LTD. and hence the right to modify any specification without prior notice is reserved with 
the company.

D-6/2, ROAD NO. 34, WAGLE INDUSTRIAL ESTATE, THANE 400 604, INDIA.
• TEL: + (91) 22 2158 2600 

• FAX: +(91) 22 2158 2602

• EMAIL: [email protected] 

• WEB: www.hdfire.com

HD FIRE PROTECT PVT. LTD.

Protecting What Matters Most to You

HD FIRE PROTECT

PVT. LTD.

DELUGE VALVE MODEL H3

0.1

0.2

0.3

0.4

0.5

0.6

0.8

1.0

2

3

4

5

6

8

10

20

30

40

100

1000

800

600

400

300

200

2000

10000

20000

7000

5000

3000

50

 

NB

 

(

 

2

 

IN

CH

 

)

80

 

NB

 

(

 

3IN

CH

 

)

10

0

 

NB

 

(

 

4

 

IN

CH

 

)

15

0

 

NB

 

(

 

6

 

IN

CH

 

)

20

0

 

NB

 

(

 

8

 

IN

CH

 

)

*

*

*

*

*

* 2.3 psi Pressure loss @ 15 feet per second (4.57 m/s) velocity having flow of 594 lpm through 50NB DV
* 4.7 psi Pressure loss @ 15 feet per second (4.57 m/s) velocity having flow of 1308 lpm through 80NB DV
* 4.7 psi Pressure loss @ 15 feet per second (4.57 m/s) velocity having flow of 2255 lpm through 100NB DV
* 7.5 psi Pressure loss @ 15 feet per second (4.57 m/s) velocity having flow of 5117 lpm through 150NB DV
* 8.4 psi Pressure loss @ 15 feet per second (4.57 m/s) velocity having flow of 8854 lpm through 200NB DV

Nominal Pressure Loss vs Flow

(* Flow at 15 feet per second [4.57 meter per second]) velocity

Nominal Pressure Loss in Pounds per Square Inch  (psi)

Flow Rate in Liters Per Minute (lpm)

Содержание H3

Страница 1: ... 165 1mm REQUIREMENT SPECIFY IN ORDER DESCRIPTION Deluge Valve is known as a system control valve in a deluge system used for fast application of water in a spray system Deluge valve protects areas such as power transformer installation storage tank conveyor protection and other industrial application etc With the addition of foaming agent deluge valve can be used to protect aircraft hanger and in...

Страница 2: ...lve drops and the Deluge valve opens c ELECTRIC RELEASE TRIM To actuate a Deluge valve electrically a solenoid valve is provided to drain the water from the top chamber of the Deluge valve A pressure switch is provided to activate an electric alarm to shut down the desired equipment or to give Tripped indication of the Deluge valve In addition to this a pressure switch can also monitor Low air pre...

Страница 3: ...g connection is from the inlet of Deluge Valve Auto resetting i The deluge valve will reset automatically when releasing devices which were responsible for deluge valve opening are closed or restored back to their original status i e closing of ERS or replacing the damaged Sprinkler if release was through Sprinkler QB Detector or closing of Solenoid valve The reset time may be long or cause vibrat...

Страница 4: ... valve knob Significant accumulation indicates a possible seat leakage d Conduct the water flow test as per the system testing procedure at least once a month iv PERIODIC CHECK Conduct the water flow test by actuating few of the release devices provided in the system Clean all strainer s and line restriction nipple This test is to be carried out at least once in three months ABNORMAL CONDITION i A...

Страница 5: ...MARCH 2022 HD 235 PAGE 5 OF 16 HD FIRE PROTECT PVT LTD DELUGE VALVE MODEL H3 SIZE 200 150 100 80 50 NB 2 4 5 6 7 8 9 10 12 13 14 15 16 17 19 11 18 20 21 3 1 Groove x Groove Flange x Flange ...

Страница 6: ...1 STAINLESS STEEL 4 9151 9112 9112 BOLT 8 4 4 STAINLESS STEEL 5 3546 3545 3544 3543 3543 RUBBER CLAMP 1 1 1 1 DUCTILE IRON 6 117466 117465 117464 117463 117463 RUBBER SEAT 1 1 1 1 EPDM 7 4034 3990 4011 4041 4041 CLAPPER 1 1 1 1 DUCTILE IRON 8 117462 117461 117460 117459 117459 DIAPHRAGM 1 1 1 1 EPDM 9 3542 3541 3540 3539 3539 CLAMP RING 1 1 1 1 DUCTILE IRON 10 8806 9151 9151 9151 9151 BOLT 12 8 8 ...

Страница 7: ...E GAUGE VALVE RN RESTRICTIOIN NOZZLE AIR LINE OD OPEN DRAIN STRAINER SV SOLENOID VALVE DPA DRY PILOT ACTUATOR BY USER PS1 LOW AIR ALARM PRESSURE SWITCH NRV NON RETURN VALVE PS2 WATER FLOW PRESSURE ALARM SWITCH OPTIONAL FLANGE X FLANGE GROOVE X GROOVE FLANGE X FLANGE GROOVE X GROOVE PG M OD INLET OUTLET OD DV PS2 PG DPA RN LINE TO DETECTION OD AIR SUPPLY PS1 PG NRV SV PG M OD INLET OUTLET OD DV PS2...

Страница 8: ...NIPPLE M EMERGENCY RELEASE STATION PG PRESSURE GAUGE VALVE RN RESTRICTIOIN NOZZLE AIR LINE OD OPEN DRAIN STRAINER SV SOLENOID VALVE DPA DRY PILOT ACTUATOR BY USER PS1 LOW AIR ALARM PRESSURE SWITCH NRV NON RETURN VALVE PS2 WATER FLOW PRESSURE ALARM SWITCH OPTIONAL PG M OD INLET OUTLET OD DV G OD TO DETECTION LINE PG NRV PS2 SV PG M OD INLET OUTLET OD DV G OD TO DETECTION LINE PG NRV PS2 SV PG M OD ...

Страница 9: ...SE STATION PG PRESSURE GAUGE VALVE RN RESTRICTIOIN NOZZLE AIR LINE OD OPEN DRAIN STRAINER SV SOLENOID VALVE DPA DRY PILOT ACTUATOR ANGLE VALVE PS1 LOW AIR ALARM PRESSURE SWITCH DR V DRIP VALVE BY USER PS2 WATER FLOW PRESSURE ALARM SWITCH NRV NON RETURN VALVE OPTIONAL PG M OD INLET PG OUTLET OD DV DR V OD OD OD TO DETECTION LINE PS2 SV PG M OD INLET PG OUTLET OD DV DR V OD OD OD TO DETECTION LINE P...

Страница 10: ...D NRV TO DETECTION LINE PS2 SV PG M OD INLET PG OUTLET OD DV SV G OD PS2 PG DR V DPA RN LINE TO DETECTION OD OD OD OD AIR SUPPLY NRV PS1 NRV PG M OD INLET PG OUTLET OD DV G OD PG DR V DPA RN LINE TO DETECTION OD OD OD OD AIR SUPPLY NRV NRV SV PS2 PS1 ABBREVIATION SYMBOLS DV DELUGE VALVE G SPRINKLER ALARM WMG NRV WITH RESTRICTION HEX NIPPLE M EMERGENCY RELEASE STATION PG PRESSURE GAUGE VALVE RN RES...

Страница 11: ... WITH RESTRICTION HEX NIPPLE M EMERGENCY RELEASE STATION PG PRESSURE GAUGE VALVE RN RESTRICTIOIN NOZZLE AIR LINE OD OPEN DRAIN STRAINER SV SOLENOID VALVE DPA DRY PILOT ACTUATOR BY USER PS1 LOW AIR ALARM PRESSURE SWITCH NRV NON RETURN VALVE PS2 WATER FLOW PRESSURE ALARM SWITCH OPTIONAL INLET PG OUTLET PG OD M OD DV TO DETECTION LINE SV PS2 INLET PG OUTLET PG OD M OD DV TO DETECTION LINE SV PS2 INLE...

Страница 12: ...EX NIPPLE M EMERGENCY RELEASE STATION PG PRESSURE GAUGE VALVE RN RESTRICTIOIN NOZZLE AIR LINE OD OPEN DRAIN STRAINER SV SOLENOID VALVE DPA DRY PILOT ACTUATOR BY USER PS1 LOW AIR ALARM PRESSURE SWITCH NRV NON RETURN VALVE PS2 WATER FLOW PRESSURE ALARM SWITCH OPTIONAL INLET PG OUTLET PG OD M OD DV G OD TO DETECTION LINE NRV SV PS2 INLET PG OUTLET PG OD M OD DV G OD TO DETECTION LINE NRV SV PS2 INLET...

Страница 13: ... PG PRESSURE GAUGE VALVE RN RESTRICTIOIN NOZZLE AIR LINE OD OPEN DRAIN STRAINER SV SOLENOID VALVE DPA DRY PILOT ACTUATOR ANGLE VALVE PS1 LOW AIR ALARM PRESSURE SWITCH DR V DRIP VALVE BY USER PS2 WATER FLOW PRESSURE ALARM SWITCH NRV NON RETURN VALVE OPTIONAL INLET PG OUTLET PG OD M OD DV OD OD DR V OD TO DETECTION LINE SV PS2 INLET PG OUTLET PG OD M OD DV OD OD DR V OD TO DETECTION LINE SV PS2 INLE...

Страница 14: ...TO DETECTION LINE G OD NRV PS2 SV ABBREVIATION SYMBOLS DV DELUGE VALVE G SPRINKLER ALARM WMG NRV WITH RESTRICTION HEX NIPPLE M EMERGENCY RELEASE STATION PG PRESSURE GAUGE VALVE RN RESTRICTIOIN NOZZLE AIR LINE OD OPEN DRAIN STRAINER SV SOLENOID VALVE DPA DRY PILOT ACTUATOR ANGLE VALVE PS1 LOW AIR ALARM PRESSURE SWITCH DR V DRIP VALVE BY USER PS2 WATER FLOW PRESSURE ALARM SWITCH NRV NON RETURN VALVE...

Страница 15: ...VALENT LENGTH BASED ON 1 2 SCHEDULE 40 PIPE WITH C 120 KG SQ CM METERS MAXIMUM PILOT LINE HEIGHT FT 60 20 20 40 120 80 100 140 5 10 15 20 25 30 35 40 40 2 4 6 8 10 12 160 180 200 14 16 18 45 50 55 60 50 100 150 200 250 0 220 65 25 FEET 250 FEET 500 FEET 60 20 20 40 120 80 100 140 5 10 15 20 25 30 35 40 40 2 4 6 8 10 12 160 180 200 14 16 18 45 50 55 60 50 100 150 200 250 0 220 65 25 FEET 250 FEET 5...

Страница 16: ...including but not limited to any implied warranties or merchantability or fitness for a particular purpose All such other warranties and representations are hereby cancelled NOTICE The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherev...

Отзывы: