7
r
oom
m
oDe
o
Ption
MODE SETUP
1) MODE
ROOM
2) SENSOR 1
FLOOR
Room Mode
Sensor temperature providing feedback for the
specific room or zone being controlled by the
thermostat.
Room Mode: Sensor 1
None
– No external thermistor attached.
RM/Ave
– averages external 1 and internal sensor.
Outdoor
– Uses external sensor to display outdoor
temperature.
Room
- disregards internal sensor, uses external 1.
Floor
– displays the floor temperature using external
1 sensor.
MODE SETUP
1) MODE
ROOM
2) SENSOR 1
FLOOR
D
ual
m
oDe
o
Ption
MODE SETUP
1) MODE
DUAL
2) FLOOR MAX
80
°F
3) FLOOR MIN
70
°F
4) SENSOR 1
FLOOR
Dual Mode
Sensor temperature providing feedback for both
the air temperature and floor sensor temperatures.
Only available when heating modes are the
primary function.
Dual Mode: Floor Maximum
The thermostat will not allow the temperature in
the floor to go above this value, protecting the
integrity of the floor covering.
MODE SETUP
1) MODE
DUAL
2) FLOOR MAX
80
°F
3) FLOOR MIN
70
°F
4) SENSOR 1
FLOOR
Dual Mode: Floor Minimum
The thermostat will not allow the temperature in
the floor to go below this value, protecting the
integrity of the floor covering. If in a 2 stage heating
mode, only the radiant heating contact is turned
off.
MODE SETUP
1) MODE
DUAL
2) FLOOR MAX
80
°F
3) FLOOR MIN
70
°F
4) SENSOR 1
FLOOR
Dual Mode: Sensor 1
This option will be automatically set to floor sensor.
MODE SETUP
1) MODE
DUAL
2) FLOOR MAX
80
°F
3) FLOOR MIN
70
°F
4) SENSOR 1
FLOOR