INTRODUCTION

This manual will help with the installation, parameter setting, troubleshooting 

and general maintenance requirements for the Controller. To guarantee the 

safe and reliable operation of this Control, you must first read this manual in 

detail and take particular note to any and all warnings or caution directives 

prior to connecting to AC power.

Only suitably qualified individuals with formal training in electrical and HVAC 

controls should attempt the installation of this equipment. Incorrect wiring 

and installation will affect the warranty provided with this unit. Wiring must be 

completed in accordance with the codes and practices applicable to the 

jurisdiction for the actual installation.

The HBX THM-0300 is a microprocessor based controller and as such is not to 

be regarded as a safety (limit) control. Please consult and install the heating or 

cooling appliance in accordance with the manufacturer’s recommendations.

 

 SAFETY SYMBOLS AND WARNINGS

  

D

rawing

 r

eference

 

 Refer to the specified electrical or mechanical drawing at the back  

 

 of the manual.

P

recaution

A measure taken in advance to prevent dangerous or an  

 

 

unpleasant event  

TABLE OF CONTENTS

Introduction 

      Index

Safety 

symbols 

and 

Warnings 

    Index

Receipt 

and 

Inspection 

     1

Description 

      1

Technical 

data 

and 

dimensions 

    1

Programming 

THM-0300 

     2 

9

Navigating 

the 

THM-0300 

    2

- Setting the THM-0300   

 

 

 

 

2 - 4

Special 

Functions 

     2 

4

Adjustments 

      5 

9

Installation 

and 

Wiring 

     10 

12

Limited 

Warranty      13 

Index

Содержание THM-0300

Страница 1: ...HBX Control Systems Inc Installation Manual THM 0300 Programmable Thermostat Version 1 00 THM 0300...

Страница 2: ...ith the codes and practices applicable to the jurisdiction for the actual installation The HBX THM 0300 is a microprocessor based controller and as such is not to be regarded as a safety limit control...

Страница 3: ...r the THM 0300 screen to blink upon startup The THM 0300 has one external sensor input multiple heating cooling modes and can function as a digital setpoint aquastat Some features of the THM 0300 are...

Страница 4: ...Special Functions screen by holding down the and buttons simultaneously for 5 seconds from the Status Screen To select the desired option use the and buttons to toggle and the set button to select 1 T...

Страница 5: ...ES 5 ROOM OFFSET 0 F 6 C OR F F SPECIAL FUNCTIONS 2 Cool Heat Function Select the 2 Cool Heat Function for applications using 2 stage cooling and 1 stage heating 1 TYPE 2 COOL WITH HEAT 2 VIEW ALL YES...

Страница 6: ...tback Allows you to program a setback A setback can be programmed to maximize energy during time frames where the zone may be vacant When you select YES you can program up to 4 setback time period 1 T...

Страница 7: ...ws the user to return to the previous screen START HEAT 1 6 00A 74 F 2 8 00A 64 F 3 4 30P 72 F 4 9 00P 90 F 5 BACK WEEKDAY PROGRAMS Weekend Programs Adjust four time periods within the two weekend pro...

Страница 8: ...ur zone If the temperature in the zone increases above this temperature cooling will come on Changeover Auto this option allows you to change automatically from heat mode to cool mode or vice versa He...

Страница 9: ...ding feedback for both the air temperature and floor sensor temperatures Only available when heating modes are the primary function Dual Mode Floor Maximum The thermostat will not allow the temperatur...

Страница 10: ...erential around the target to lesson the chances of short cycling MODE SETUP 1 MODE FLOOR 2 DIFF 5 F 3 SENSOR 1 FLOOR Floor Mode Sensor 1 This option will be automatically set to floor sensor MODE SET...

Страница 11: ...et a priority on a zone s over other zone s Priorities range from 1 highest to 8 lowest Higher priorities will lock out lower priorities until the demand has been satisfied Multiple zones can be given...

Страница 12: ...on the fancoil FANCOIL SETUP 1 FAN ON DMD NO 2 ZONE ON DMD NO 3 TEMP AVE NONE 4 FAN MODE OFF Fancoil Setup Fan Mode OFF Indicated Fan is off ON Enables the fan to run constantly regardless of whether...

Страница 13: ...HEDULE 2 MODE 3 SYSTEM SETUP 4 TIME Time Setup This setting takes you to the Time Setup Menu Time Setup Time Set the time for your appropriate time zone TIME SETUP 1 TIME 1 00pm 2 DAY OF WEEK MON 3 TI...

Страница 14: ...ng the thermostat to direct sunlight to air flows doors windows etc as well as to heat sources Wiring Examples To ZON 0550 THM 0300 HBX 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POW...

Страница 15: ...on repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise inclu...

Страница 16: ...V1 02...

Отзывы: