ARC 800 Order No. BA 93-10-0702A Issue 01.03.08
31
Determination of welding time
Data given in the following table are only guidelines. They must
be verified by trial welds on the actual material according to
actual standards and DVS guidelines (see appendix). Before
you use another lot of welding elements, carry out some trial
welds to verify the parameter setting.
Setting of power unit
(metric)
(imperial)
(metric)
(imperial)
(metric/mm)
(imperial)
M3
1/8''
not normed
-
3
#4 or 12 gage
3
#4 or 12 gage
20
M4
5/32''
not normed
-
4
#8
4
#8
35
M5
3/16''
not normed
-
5
#10 or 3/16''
5
#10 or 3/16''
50
M6
1/4''
4,7/0.19
45
6
1/4''
6
1/4''
75
M8
5/16''
6,2/0.24
80
8
5/16''
8
5/16''
130
M10
3/8''
7,9/0.31
130
10
7/16''
10
7/16''
200
(metric)
(imperial)
(metric)
(metric)
(metric/mm)
(imperial)
M3
1/8''
not normed
-
M3
1/8''
4
#8
35
M4
5/32''
not normed
-
M4
5/32''
5
#10 or 3/16''
50
M5
3/16''
not normed
-
M5
3/16''
6
1/4''
75
M6
1/4''
5,4/0.21
60
M6
1/4''
7
0.28''
100
M8
5/16''
7,19/0.28
100
M8
5/16''
9
0.35''
170
M10
3/8''
9/0.35
165
M10
3/8''
11
0.43''
250
Designation
PD (MD)
Designation
PS (FD)
Welding
time in ms
Eff. diameter in mm
Welding
time in ms
Eff. diameter
(mm/inches)
Welding
time in ms
Designation
RD
Eff. diameter
(mm/inches)
Designation
UD / Pins
Eff. diameter in mm
Welding
time in ms
Setting of welding gun
Plunging depth
Lift
Plunging depth
Lift
(metric/mm)
(imperial)
3
#4 or 12 gage
1,0
1,0
2,5
1,5
4
#8
1,0
1,0
2,5
1,5
5
#10 or 3/16"
1,0
1,0
2,5
1,5
6
1/4"
1,0
1,0
2,5
1,5
8
5/16"
1,0
1,0
2,5
2,0
10
7/16"
1,5
1,5
2,5
2,0
12
1/2"
1,5
1,5
3,0
2,0
Eff. diameter
Preferably under shielding gas
Preferably with ceramic ferrule
Welding element with
conical face
Welding element with
plane face
Further notes on
– welding elements
– prestress at installation (tie load) and torque
– material combinations
see appendix and operating manual of the according welding
gun.
Содержание 93-10-0702A
Страница 1: ...ARC 800 Power Unit 93 10 0702A Operating Manual...
Страница 8: ...viii ARC 800 Order No BA 93 10 0702A Issue 01 03 08...
Страница 47: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 47 Power unit ARC 800 93 10 0702A...
Страница 49: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 49 Front plate complete ARC 800 88 11 268A...
Страница 53: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 53 Rear wall complete ARC 800 88 11 259A...
Страница 55: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 55 Bottom unit complete ARC 800 88 11 386...
Страница 57: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 57 Shielding gas module ARC 800 93 50 020...
Страница 60: ...60 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 Main board 80 80 497 Please observe the program version...
Страница 61: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 61 Transformer board 80 80 491...
Страница 62: ...62 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 8 3 Electrical Circuit Diagram...
Страница 72: ...72 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 Service Support...
Страница 76: ...76 ARC 800 Order No BA 93 10 0702A Issue 01 03 08...
Страница 77: ......