30
ARC 800 Order No. BA 93-10-0702A Issue 01.03.08
5.2.4 Drawn-Arc Capacitor-Discharge Stud Welding
With drawn-arc capacitor-discharge stud welding, the welding energy is taken from a
capacitor. As a result, welding currents are very high and welding times (< 10 ms) very
short. Normally, a weld pool protection is not required. The process is mainly used for
welding elements in a diameter range of up to 8 mm.
5.3
Welding Preparation
Read the safety instructions in chapters 1, 3 and 5.
Observe the workplace requirements (chapter 3, ”Starting-up").
Check all cables and connections for proper condition.
Replace immediately defective cables and cable connections to avoid electrical
shocks.
Check the chuck for proper seat (see operating manual of according welding
gun).
Before welding, make sure that the bellows are checked for damage and proper
seat.
5.4
High-strength Welds
The following must be removed both from the weld zone and the ground clamp
connection areas:
– paint, oil and any other impurities,
– rust,
– non-conductive coatings from surface treated workpieces.
Weld to smooth and flat surfaces only.
For welding to pipes or punched plates consult our responsible
application manager (address of customer service see page ii).
5.5
Determination of Welding Parameters
The adjustment of welding parameters on the power unit (e.g. welding time) or on the
welding gun (e.g. lift) depends amongst others on
– material of the welding element
– diameter of the welding element
– material of the workpiece
The guidelines should be verified by test welding on the actual material and be changed
if necessary. For an assessment of welding results, see sections 5.8 and 5.9.
Содержание 93-10-0702A
Страница 1: ...ARC 800 Power Unit 93 10 0702A Operating Manual...
Страница 8: ...viii ARC 800 Order No BA 93 10 0702A Issue 01 03 08...
Страница 47: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 47 Power unit ARC 800 93 10 0702A...
Страница 49: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 49 Front plate complete ARC 800 88 11 268A...
Страница 53: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 53 Rear wall complete ARC 800 88 11 259A...
Страница 55: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 55 Bottom unit complete ARC 800 88 11 386...
Страница 57: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 57 Shielding gas module ARC 800 93 50 020...
Страница 60: ...60 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 Main board 80 80 497 Please observe the program version...
Страница 61: ...ARC 800 Order No BA 93 10 0702A Issue 01 03 08 61 Transformer board 80 80 491...
Страница 62: ...62 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 8 3 Electrical Circuit Diagram...
Страница 72: ...72 ARC 800 Order No BA 93 10 0702A Issue 01 03 08 Service Support...
Страница 76: ...76 ARC 800 Order No BA 93 10 0702A Issue 01 03 08...
Страница 77: ......