Mounting
24
A0162-8.0
HBM: public
TB1A
Important
Even in a resonance situation, you must keep to the
mechanical limits. Torsion spring rigidity and moment of
inertia for estimating the the natural frequency, can be
found in Chapter 9.
+M
N
100 %
-M
N
100 %
0
90
70
Nominal torque M
N
in %
160 % (120 %) M
N
vibration bandwidth
Fig. 5.7
Permissible dynamic loading