Mounting
TB1A
A0162-8.0
HBM: public
19
CAUTION
It is essential to keep to the maximum thread reach in the
mounting flange (as per Tab. 5.1) ! Otherwise, consider
able measurement errors might occur or the transducer
might suffer damage.
Nominal
torque
(N
V
m)
Fastening
bolts (Z)
measur
ing body
Fastening
bolts
property
class
Maximum thread reach (Y)
of the screws in the
mounting flange
(mm)
Prescribed
tightening
torque
(N
V
m)
100
M6
10.9
7.5
14
200
mM8
11
34
500
M12
18
115
1k
M12
18
115
2k
M14
18
185
5k
M18
33.5
400
10k
M18
12.9
33.5
470
Tab. 5.1
Fastening bolts
1)
If screws of Class 12.9 are not available, Class 10.9 screws (400 N
⋅
m tightening torque) can be
used. The permissible limiting torque is reduced then to 120 % referred to M
N
.